• 2*10 AWG Stranded Copper Electrical Wire
  • 2*10 AWG Stranded Copper Electrical Wire
  • 2*10 AWG Stranded Copper Electrical Wire
  • 2*10 AWG Stranded Copper Electrical Wire
  • 2*10 AWG Stranded Copper Electrical Wire
  • 2*10 AWG Stranded Copper Electrical Wire

2*10 AWG Stranded Copper Electrical Wire

Application: Construction, Underground, Industrial, Power Station, Telecommunication
Voltage: Low and Medium Voltage Cable
Current: AC Cable
Insulation Material: XLPE
Sheath Material: PVC
Material Shape: Round Wire
Samples:
US$ 100/Meter 1 Meter(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
YJV
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC
Model
YJV
Brand
OEM
Transport Package
in Drum or in Coil
Specification
4**10
Trademark
OEM
Origin
Henan
HS Code
8544492100
Production Capacity
10000 M Per Day

Product Description

Al/CU Conductor XLPE/PVC Insulated Thin/Thick steel armored PE Sheathed Power Cable.
Relative manufacturing standards: IEC60505, BS, DIN,ASTM,JIS or other standards.
 
Application: 
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
 
Using features: 
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV and 0.6/1kV.
2. No. Of core: Single-core, Two-core,Three-core,Four-core,Five-core,Six-core.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250oC. 
4. D. C. Resistance of the conductor complies with the stipulations of international standar. 
5. The environment temperature should be no lower than zero degree when lay. Otherwise it should be preheated. 
6. The cable is laid without horizontal drop limit. The Min. Bending radius of cables should be no smaller than 12 times of cable outer diameter. 
7. Working Frequency Voltage Test: 
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture. 
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture. 
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture. 
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable
 
This series includes:
Copper (aluminum) conductor, XLPE/PVC insulated ,PVC sheathed power cables 
Copper (aluminum) conductor, XLPE/PVC insulated, PE sheathed power cables 
Copper (aluminum) conductor, XLPE/PVC insulated, steel tape armoring(DSTA) PVC sheathed power cables 
Copper (aluminum) conductor, XLPE/PVC insulated, steel tape armoring(DSTA), PE sheathed power cables 
Copper (aluminum) conductor, XLPE/PVC insulated, steel wire armoring(SWA), PVC sheathed power Cables 
Copper (aluminum) conductor, XLPE/PVC insulated, steel wire armoring(SWA), PE sheathed power cables

2*10 AWG Stranded Copper Electrical Wire




 

Send your message to this supplier

*From:
*To:
avatar Mrs. Hong Li
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
43
Year of Establishment
2013-12-06