• Acyy / Acyy-F 0.6/1kv Aluminium Conductor PVC Insulated and Sheathed Cable
  • Acyy / Acyy-F 0.6/1kv Aluminium Conductor PVC Insulated and Sheathed Cable
  • Acyy / Acyy-F 0.6/1kv Aluminium Conductor PVC Insulated and Sheathed Cable
  • Acyy / Acyy-F 0.6/1kv Aluminium Conductor PVC Insulated and Sheathed Cable
  • Acyy / Acyy-F 0.6/1kv Aluminium Conductor PVC Insulated and Sheathed Cable
  • Acyy / Acyy-F 0.6/1kv Aluminium Conductor PVC Insulated and Sheathed Cable

Acyy / Acyy-F 0.6/1kv Aluminium Conductor PVC Insulated and Sheathed Cable

Application: Construction, Underground, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Current: DC Cable
Insulation Material: PVC
Sheath Material: PVC
Material Shape: Round Wire
Samples:
US$ 1/Meter 1 Meter(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
cablu acyy
Wire Core Material
Aluminum Conductor
Certification
ISO, CCC
Model
Acyy / Acyy-F
Brand
Hongda Cable
Insulation
PVC Insulated
Sheath
PVC (Polyvinyl Chloride), Fire Resistant
Transport Package
500m Per Drum
Specification
1.5 - 300 sq. mm
Trademark
Hongda
Origin
China
HS Code
8544492100
Production Capacity
20 Kilometers Per Day

Product Description

ACYY / ACYY-F - Low voltage power cable 0.6/1 kV

1. Cable construction
Conductor: aluminum (class 1 or 2), monowire (re), multiwire (rm).
Insulation: PVC
Filling.
Outer sheath: PVC, black or grey.
Acyy / Acyy-F 0.6/1kv Aluminium Conductor PVC Insulated and Sheathed Cable


Application
Power supply to power stations. The cables can be installed in open or confined areas, underground (in pipes), in sewers, in concrete, in places where no mechanical damage is expected.

ACYY / ACYY-F  low voltage power cable 0.6./1 kV - Technical data and tests
Conductor type : monowire (re), multiwire (rm)
Rated voltage Uo/U :  0.6/1 kV
Test voltage : 4 kV AC or 12 kV DC, 5 min
Min. temperature of cable : installation :   -5º C
Max. allowed operating temperature : 70º C
Max. short-circuit temperature : 160º C
Min. bending radius : 15 x cable diameter - single-core cable
12 x cable diameter - multicore cable
Max. tensile strain during installation : max 50 N/mm²
Color coding : 1 conductor-blue or yellow-green;
2 conductors - blue,brown;
   - yellow-green,black for sect > 10 mm²;
3 conductors - brown,black,grey;      
   - yellow-green, blue,brown;
4 conductors - blue, brown, black,grey;      
   - yellow-green, brown,black,grey;
 5 conductors - blue, brown, black, grey, black;    
    - yellow-green, blue, brown, black,grey;
More than 5 conductors: - numbered black conductors;
   - yellow-green and numbered conductors.
Standards:
Cable                : IEC 60502-1.
Conductors        : IEC 60228.
Insulation          : IEC 60502-1.
Flame retardancy:
ACYY    : EN 50265-2-1 (IEC 60332-1) - flames on a single vertical cable.  
ACYY-F : EN 50266-2-4 (IEC 60332-3-25 Cat. C) - flames on a bundle of cables.

ACYY / ACYY-F  low voltage power cable 0.6./1 kV - Applications
ACYY / ACYY-F is a cable for power supply to power stations. This cable can be installed in open or confined areas, underground (in pipes), in sewers, in concrete, in places where no mechanical damage is expected.
 
ACYY / ACYY-F  low voltage power cable 0.6./1 kV - Other standards
British             : AL/PVC/PVC.
German           : NAYY.
Austrian           : E-AYY.
Russian            : АВВГ.
Central Europe : PP 00-A.
Turkish            : YAVV-R.

2. Construction data of power cables / CYABY-F
Cable Size Type of Conductor Radial Thickness of Insulation Radial Thickness of Sheath Outer Diameter Approx. Cable Weight
    mm mm mm kg/km
1x4 re 1 1.4 7.9 66
1x6 re 1 1.4 8.4 78
1x10 re 1 1.4 9.2 98
1x16 re 1 1.4 10.9 126
1x25 re 1.2 1.4 12.6 188
1x35 re 1.2 1.4 13.8 230
1x50 rm 1.4 1.4 15.6 297
1x70 rm 1.4 1.5 17.3 388
1x95 rm 1.6 1.6 19.7 58
1x120 rm 1.6 1.6 21 605
1x150 rm 1.8 1.7. 23.1 743
1x185 rm 2 1.7. 25.5 922
1x240 rm 2.2 1.9 30.2 1176
1x300 rm 2.4 2 31.3 1431
2x4 re 1 1.8 12.3 207
2x6 re 1 1.8 13.5 255
2x10 re 1 1.8 15.1 326
2x16 re 1 1.8 18.8 430
2x25 re 1.2 1.8 22.2 678
2x35 re 1.2 1.8 24.6 841
3x4 re 1 1.8 13 233
3x6 re 1 1.8 14.3 287
3x10 re 1 1.8 16 371
3x16 re 1 1.8 20 471
3x25 re 1.2 1.8 23.6 773
3x25+16 re/re 1.2/1.0 1.8 25 840
3x35 re 1.2 1.8 26.2 961
3x35+16 re/re 1.2/1.0 1.8 27.1 978
3x50 sm 1.4 1.8 25 814
3x50+25 sm/rm 1.4/1.2 1.9 29 1025
3x70 sm 1.4 1.9 28 1170
3x70+35 sm/rm 1.4/1.2 2 35 1354
3x95 sm 1.6 2.1 30 1530
3x95+50 sm/sm 1.6/1.4 2.2 41 1844
3x120 sm 1.6 2 33 1879
3x120+70 sm/sm 1.6/1.4 2.3 45 2187
3x150 sm 1.8 2.2 36.9 2327
3x150+70 sm/sm 1.8/1.4 2.4 49 2648
3x185 sm 2 2.3 40.9 2892
3x185+95 sm/sm 2.0/1.6 2.6 53 3343
3x240 sm 2.2 2.5 47.5 4380
3x240+120 sm/sm 2.2/1.6 2.8 60 4258
4x4 re 1 1.8 14.1 276
4x6 re 1 1.8 15.5 342
4x10 re 1 1.8 17.5 445
4x16 re 1 1.8 21.9 595
4x25 rm 1.2 1.8 26 939
4x35 rm 1.2 1.8 29.3 1205
4x50 sm 1.4 1.9 29 1137
4x70 sm 1.4 2 33.2 1478
4x95 sm 1.6 2.1 36 2037
4x120 sm 1.6 2.3 40 2422
4x150 sm 1.8 2.4 43 2979
4x185 sm 2 2.5 48.2 3500
4x240 sm 2.2 2.7 54.2 4590
5x4 re 1 1.8 15.3 339
5x6 re 1 1.8 16.9 406
5x10 re 1 1.8 19 523
5x16 re 1 1.8 23.9 713
5x25 re 1.2 1.9 28.7 1148
5x35 re 1.2 2 32.5 1488

Acyy / Acyy-F 0.6/1kv Aluminium Conductor PVC Insulated and Sheathed Cable
Acyy / Acyy-F 0.6/1kv Aluminium Conductor PVC Insulated and Sheathed Cable


3. Contact information:
Any needs or question ,please contact us ,we will be more pleasure to service you.
We are looking forward to your inquiry and nice cooperaton.
Acyy / Acyy-F 0.6/1kv Aluminium Conductor PVC Insulated and Sheathed Cable
Acyy / Acyy-F 0.6/1kv Aluminium Conductor PVC Insulated and Sheathed Cable
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now