• Steel Wire Armoured Low Voltage Power Cables N2xry & N2xrh Cable
  • Steel Wire Armoured Low Voltage Power Cables N2xry & N2xrh Cable
  • Steel Wire Armoured Low Voltage Power Cables N2xry & N2xrh Cable
  • Steel Wire Armoured Low Voltage Power Cables N2xry & N2xrh Cable
  • Steel Wire Armoured Low Voltage Power Cables N2xry & N2xrh Cable
  • Steel Wire Armoured Low Voltage Power Cables N2xry & N2xrh Cable

Steel Wire Armoured Low Voltage Power Cables N2xry & N2xrh Cable

Application: Construction, Underground, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Current: AC Cable
Insulation Material: XLPE
Sheath Material: PVC
Material Shape: Round Wire
Samples:
US$ 12/Meter 1 Meter(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
N2XRH Cable
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE
Model
N2xry & N2xrh Cable
Brand
Hongda Cable
Armoured
Steel Wire
Voltage Rating
600V/1000V
N2xry
PVC Insulated and Sheathed Cable
N2xrh
Low Smoke Zero Halogen Cable
Transport Package
Steel & Wooden Drum
Specification
1.5mm2 to 400mm2
Trademark
Hongda Cable
Origin
China
HS Code
8544492100
Production Capacity
300km/Month

Product Description

Steel wire armoured low voltage power cables N2XRY & N2XRH Cable

1. Overview
N2XRY cables and N2XRH cables form part of our range of steel wire armoured low voltage power cables we offer in our portfolio. These cables are the copper conductor equivalent of the NA2XRH and NA2XRY cables, delivering a voltage rating of 0.6/1kV (600V/1000V) and a maximum temperature rating of 90oC. The addition of SWA armouring allows for these cables to be direct buried in the ground without additional protection, protecting them from mechanical stresses and the risk of damage from external forces. The black outer sheath offers UV protection in keeping with their use outdoors.

N2XRY is a PVC insulated and sheathed cable, comparable to the British standard cable 
BS5467. The N2XRH cable uses Low Smoke Zero Halogen compounds (also known as HFFR - halogen free flame retardant) and is comparable to the BS6724cable. The LSZH cable provides additional protection in the event of a fire, emitting none of the harmful halogen gases such as chlorine gas and emits reduced levels of the dense black smoke compare to PVC sheathed cables. As a result, the N2XRH cable is widely used in public buildings, tall constructions, as well as in refineries, automation plants and data centres - application where smoke emissions and toxic fumes could pose a risk to human health and sensitive equipment in the event of a fire.

2. Cable Types

N2XRH / N2XRY CABLE CODE

N Standard metal cable type (copper)
2X XLPE insulation
R Round steel wire armour
H HFFR outersheath
Y PVC outersheath 
Steel Wire Armoured Low Voltage Power Cables N2xry & N2xrh Cable
3. Construction Table
  N2XRY CABLE N2XRH CABLE
VOLTAGE

0.6/1kV

CONDUCTOR

Class 2 Stranded Copper

INSULATION

XLPE (Cross-Linked Polyethylene)

BEDDING

PVC (Polyvinyl Chloride)

LSZH (Low Smoke Zero Halogen)

ARMOUR

SWA (Galvanised Steel Wire)

OUTER SHEATH

PVC (Polyvinyl Chloride)

LSZH (Low Smoke Zero Halogen)


4. BS 6724 SWA LSZH 0.6/1kV Cable
Dimensions - BS5467 XLPE/LSZH/SWA/LSZH (Copper)
No. of Cores Nominal Cross Sectional Area Nominal Thickness of Insulation Nominal Overall Diameter mm Nominal Weight
mm² mm Under Armour Overall kg/km
2 1.5 0.6 7.3 12.1 302
2 2.5 0.7 8.5 13.6 346
2 4 0.7 9.4 14.7 410
2 6 0.7 10.5 15.9 499
2 10 0.7 12.3 18 648
2 16 0.7 14.3 20.4 978
2 25 0.9 14.7 20.4 1290
2 35 0.9 16.8 23.3 1500
2 50 1 19 25.8 1890
2 70 1.1 22 29 2450
2 95 1.1 25.1 33.1 3300
2 120 1.2 27.9 36.1 4020
2 150 1.4 30.9 39.3 4750
3 1,5 0.6 7.8 12.6 330
3 2.5 0.7 9.2 14.1 390
3 4 0.7 10 15.3 464
3 6 0.7 11.2 16.6 568
3 10 0.7 13.1 19.5 866
3 16 0.7 15.3 21.6 1152
3 25 0.9 18.9 23.6 1800
3 35 0.9 21.3 25.7 2230
3 50 1 21.7 28.5 2490
3 70 1.1 25.2 32.2 3290
3 95 1.1 28.8 37 4440
3 120 1.2 32 40.4 5470
3 150 1.4 35.9 45.5 6930
3 185 1.6 40 49.8 8350
3 240 1.7 44.9 55.1 10400
3 300 1.8 49.8 60.2 12600
3 400 2 55.8 66.6 14600
4 1.5 0.6 8.5 13.3 365
4 2.5 0.7 9.9 15 438
4 4 0.7 11 16.4 532
4 6 0.7 12.3 18.7 764
4 10 0.7 14.5 21.1 1013
4 16 0.7 17 23.4 1360
4 25 0.9 21 26.1 2160
4 35 0.9 23.6 28.6 2690
4 50 1 25 32 3130
4 70 1.1 29.5 37.7 4500
4 95 1.1 33.3 41.7 5600
4 120 1.2 37.5 47.1 7400
4 150 1.4 41.6 51.4 8780
4 185 1.6 46.4 56.6 10630
4 240 1.7 52.6 63 13390
4 300 1.8 58 68.8 16290
4 400 2 65.4 78.1 19800
5 1.5 0.6 9.7 14.3 410
5 2.5 0.7 11.7 16.1 470
5 4 0.7 13 17.8 710
5 6 0.7 14.5 20 876
5 10 0.7 17.2 22.9 1165
5 16 0.7 20 26.6 1742
5 25 0.9 24.7 31.5 2323
5 35 0.9 27.8 34.8 2932
5 50 1 32.4 40.4 4192
7 1.5 0.6 10.2 15.2 470
7 2.5 0.7 12.3 17.1 600
7 4 0.7 13.6 19.1 881
12 1.5 0.6 13.7 19.4 780
12 2.5 0.7 16.3 22.4 1000
19 1.5 0.6 16.2 22.2 1000
19 2.5 0.7 19.9 26.6 1540
27 1.5 0.6 20 26.7 1500
27 2.5 0.7 24 30.7 1950
37 1.5 0.6 22.3 29 1800
37 2.5 0.7 26.9 33.8 2350

Class 2 Stranded Conductors for Single Core and Multi-Core Cables
Nominal Cross 
Sectional Area
Minimum No. Of Wires In Conductor Maximum Resistance 
of Conductor At 20ºC
mm² Circular Circular Compacted Shaped Annealed Copper Conductor
Cu Al Cu Al Cu Al Plain Wires ohms/km
1.5 7 - 6 - - - 12.1
2.5 7 - 6 - - - 7.41
4 7 - 6 - - - 4.61
6 7 - 6 - - - 3.08
10 7 7 6 6 - - 1.83
16 7 7 6 6 - - 1.15
25 7 7 6 6 6 6 0.727
35 7 7 6 6 6 6 0.524
50 19 19 6 6 6 6 0.387
70 19 19 12 12 12 12 0.268
95 19 19 15 15 15 15 0.193
120 37 37 18 15 18 15 0.153
150 37 37 18 15 18 15 0.124
185 37 37 30 30 30 30 0.0991
240 37 37 34 30 34 30 0.0754

Steel Wire Armoured Low Voltage Power Cables N2xry & N2xrh Cable

4.2 BS 5467 SWA PVC 0.6/1kV Cable
Dimensions - BS5467 XLPE/PVC/SWA/PVC (Copper)
No. of Cores Nominal Cross Sectional Area Nominal Thickness of Insulation Nominal Overall Diameter mm Nominal Weight
mm² mm Under Armour Overall kg/km
2 1.5 0.6 7.3 12.1 302
2 2.5 0.7 8.5 13.6 346
2 4 0.7 9.4 14.7 410
2 6 0.7 10.5 15.9 499
2 10 0.7 12.3 18 648
2 16 0.7 14.3 20.4 978
2 25 0.9 14.7 20.4 1290
2 35 0.9 16.8 23.3 1500
2 50 1 19 25.8 1890
2 70 1.1 22 29 2450
2 95 1.1 25.1 33.1 3300
2 120 1.2 27.9 36.1 4020
2 150 1.4 30.9 39.3 4750
3 1,5 0.6 7.8 12.6 330
3 2.5 0.7 9.2 14.1 390
3 4 0.7 10 15.3 464
3 6 0.7 11.2 16.6 568
3 10 0.7 13.1 19.5 866
3 16 0.7 15.3 21.6 1152
3 25 0.9 18.9 23.6 1800
3 35 0.9 21.3 25.7 2230
3 50 1 21.7 28.5 2490
3 70 1.1 25.2 32.2 3290
3 95 1.1 28.8 37 4440
3 120 1.2 32 40.4 5470
3 150 1.4 35.9 45.5 6930
3 185 1.6 40 49.8 8350
3 240 1.7 44.9 55.1 10400
3 300 1.8 49.8 60.2 12600
3 400 2 55.8 66.6 14600
4 1.5 0.6 8.5 13.3 365
4 2.5 0.7 9.9 15 438
4 4 0.7 11 16.4 532
4 6 0.7 12.3 18.7 764
4 10 0.7 14.5 21.1 1013
4 16 0.7 17 23.4 1360
4 25 0.9 21 26.1 2160
4 35 0.9 23.6 28.6 2690
4 50 1 25 32 3130
4 70 1.1 29.5 37.7 4500
4 95 1.1 33.3 41.7 5600
4 120 1.2 37.5 47.1 7400
4 150 1.4 41.6 51.4 8780
4 185 1.6 46.4 56.6 10630
4 240 1.7 52.6 63 13390
4 300 1.8 58 68.8 16290
4 400 2 65.4 78.1 19800
5 1.5 0.6 9.7 14.3 410
5 2.5 0.7 11.7 16.1 470
5 4 0.7 13 17.8 710
5 6 0.7 14.5 20 876
5 10 0.7 17.2 22.9 1165
5 16 0.7 20 26.6 1742
5 25 0.9 24.7 31.5 2323
5 35 0.9 27.8 34.8 2932
5 50 1 32.4 40.4 4192
7 1.5 0.6 10.2 15.2 470
7 2.5 0.7 12.3 17.1 600
7 4 0.7 13.6 19.1 881
12 1.5 0.6 13.7 19.4 780
12 2.5 0.7 16.3 22.4 1000
19 1.5 0.6 16.2 22.2 1000
19 2.5 0.7 19.9 26.6 1540
27 1.5 0.6 20 26.7 1500
27 2.5 0.7 24 30.7 1950
37 1.5 0.6 22.3 29 1800
37 2.5 0.7 26.9 33.8 2350

Class 2 Stranded Conductors for Single Core and Multi-Core Cables
Nominal Cross 
Sectional Area
Minimum No. Of Wires In Conductor Maximum Resistance 
of Conductor At 20ºC
mm² Circular Circular Compacted Shaped Annealed Copper Conductor
Cu Al Cu Al Cu Al Plain Wires ohms/km
1.5 7 - 6 - - - 12.1
2.5 7 - 6 - - - 7.41
4 7 - 6 - - - 4.61
6 7 - 6 - - - 3.08
10 7 7 6 6 - - 1.83
16 7 7 6 6 - - 1.15
25 7 7 6 6 6 6 0.727
35 7 7 6 6 6 6 0.524
50 19 19 6 6 6 6 0.387
70 19 19 12 12 12 12 0.268
95 19 19 15 15 15 15 0.193
120 37 37 18 15 18 15 0.153
150 37 37 18 15 18 15 0.124
185 37 37 30 30 30 30 0.0991
240 37 37 34 30 34 30 0.0754
300 61 61 34 30 34 30 0.0601
400 61 61 53 53 53 53 0.047
Notes
1. Where a conductor operates at a temperature exceeding 70ºC it must be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature.
2. Where cables in this table are connected to equipment or accessories designed to operate at a temperature not exceeding 70ºC , the current ratings given in the equivalent table for 70ºC thermoplastic insulated cables must be used.