Application: Construction, Underground, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Current: DC & AC
Insulation Material: XLPE
Sheath Material: Hffr/Losh/LSZH
Material Shape: Round Wire
Samples:
US$ 3/Meter 1 Meter(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
1.9/3.3kV Cable
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE, SGS
Model
Cu/XLPE/Hffr/Swa/Hffr
Brand
Hongda
Single Core Armour
Awa (Aluminum Wire Armour)
Multi Core Armour
Swa (Steel Wire Armour)
Voltage Rating
1900/3300V, 1.9/3.3kv
Temperature Rating
0°c to +90°c
Flame Retardant
IEC60332 Part 1, BS4066 Part 1
Smoke Density
IEC 61034, En50268
Transport Package
Steel & Wooden Drum
Specification
1.5mm2 to 400mm2
Trademark
Hongda Cable
Origin
China
HS Code
8544492100
Production Capacity
500km/Month

Product Description

BS 6724 Standards Armoured Power Cables, 1900/3300V
Three-core 1900/3300 V cables with stranded copper conductors

Thermosetting insulated armoured cables - 600/1000V to 1900/3300V - with low emission of smoke and corrosive gases when affected by fire. Manufactured in accordance with British Standard BS6724

1. Application

These cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The GSWA makes them suitable for use inside and outside buildings or for direct burial in the ground. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.

2. Construction

CONDUCTOR Solid Aluminum or Copper conductor, round stranded or shaped, Class 2 to BS 6460,
  IEC 60228.
INSULATION XLPE (Cross-Linked Polyethylene) Type GP 8 or ethylene propylene rubber (GP 6)
COLOUR CODE 1 Core : Brown
  2 Cores : Brown or Blue
  3 Cores: Brown, Black, Grey
  4 Cores: Blue, Brown, Black, Grey
  5 Cores: Green/Yellow, Blue, Brown, Black, Grey
  Above 5 Cores: White Cores with black numerals
BEDDING LSOH (Low Smoke Zero Halogen)
ARMOUR Single Core: AWA (Aluminum Wire Armour)
  Multi Core: SWA (Steel Wire Armour)
OUTER SHEATH LSOH (Low Smoke Zero Halogen)

Technical Information

Voltage rating 1900/3300V
Temperature rating 0°C to +90°C
Bending radius 1.5mm² to 16mm²: 6 x overall diameter
                          25mm² and above: 8 x overall diameter
Flame retardant IEC60332 part 1, BS4066 part 1
Halogen free IEC 60754, EN 50267
Smoke density IEC 61034, EN50268

3. Three-core 1900/3300 V cables with stranded copper conductors

3X95mm2 BS6724 Halogen Free Flame Retardant 1.9/3.3kv Shpd Cu XLPE Swa Hffr Cable
 
NOMINAL CROSS-SECTIONAL AREA STRAND TYPE NOMINAL INSULATION THICKNESS NOMINAL BEDDING THICKNESS NOMINAL STEEL WIRE ARMOR DIA. NOMINAL SHEATH THICKNESS APPROX OVERALL DIAMETER APRROX WEIGHT
MM² NO./MM MM MM MM MM MM KG/KM
3x16 7/1.70 2 1 1.6 1.8 29.3 1600
3x25 7/2.14 2 1 1.6 1.8 32.2 2060
3x35 7/2.52 2 1 1.6 1.9 34.8 2400
3x35* 7/2.52 2 1 1.6 1.9 31.1 2400
3x50* 19/1.78 2 1.2 2 2 34.7 3200
3x70* 19/2.14 2 1.2 2 2.1 38 3800
3x95* 19/2.52 2 1.2 2 2.2 41.4 4730
3x120* 37/2.03 2 1.4 2.5 2.3 45.7 6070
3x150* 37/2.25 2 1.4 2.5 2.4 48.5 7010
3x185* 37/2.52 2 1.4 2.5 2.5 51.9 8270
3x240* 61/2.25 2 1.6 2.5 2.6 56.9 10310
3x300* 61/2.52 2 1.6 2.5 2.7 61.2 12300
3x400* 61/2.85 2 1.6 2.5 2.9 66.6 14500

3X95mm2 BS6724 Halogen Free Flame Retardant 1.9/3.3kv Shpd Cu XLPE Swa Hffr Cable


4. Notes
1. Due to mechanical protection provided by their armours, cables manufactured to BS6724 are suitable for applications in industrial wiring and mains distribution where there is a risk of mechanical damage and for direct burial.
2. If you are considering installing in high UV exposure and/or high/low ambient temperatures i.e. desert/arctic conditions then special sheathing may be required.
3. Whilst HONGDA CABLE plc endeavours to ensure the information on the website, specification sheets and all other technical information is accurate, the information is for guidance only and it is subject to change without notice or liability. Hongda Cable Plc is not responsible for the consequences of any inadequacies, inaccuracies or other deficiencies contained therein. When selecting cable accessories, please note that the actual cable dimensions may vary due to manufacturing tolerances.

For more information, don't hesitate to call us  or send inquiry to VIVIAN.
3X95mm2 BS6724 Halogen Free Flame Retardant 1.9/3.3kv Shpd Cu XLPE Swa Hffr Cable
3X95mm2 BS6724 Halogen Free Flame Retardant 1.9/3.3kv Shpd Cu XLPE Swa Hffr Cable

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now