3-Layer 35kV Tree Wire Spacer Cable Application
The tree wire is used for primary and secondary overhead distribution where limited space is available or desired for rights-of-way. Installed the same as bare conductors, however, covering is effective in preventing direct shorts and instantaneous flashovers with other objects. The close-proximity configuration minimizes the amount of space and hardware required for line installation, making it particularly useful in congested areas such as alleyways or tight corridors.
Size (kcmil) | Equivalent AAC (AWG or kcmil) |
Stranding | Conductor Diameter (mils) |
Covering Thickness (mils) | Cable O.D. (mils) |
Rated Strength (lbs) |
Weight per 1000 ft. (lbs) |
||
Conductor Shield | Inner Layer | Outer Layer | |||||||
48.69 | 4 | 7 | 250 | 15 | 175 | 125 | 880 | 1584 | 278 |
77.47 | 2 | 7 | 316 | 15 | 175 | 125 | 946 | 2520 | 333 |
123.3 | 1/0 | 7 | 398 | 15 | 175 | 125 | 1028 | 4014 | 411 |
155.4 | 2/0 | 7 | 447 | 15 | 175 | 125 | 1077 | 4851 | 462 |
195.7 | 3/0 | 7 | 502 | 15 | 175 | 125 | 1132 | 6111 | 523 |
246.9 | 4/0 | 7 | 563 | 15 | 175 | 125 | 1193 | 7704 | 598 |
312.8 | 266.8 | 19 | 642 | 15 | 175 | 125 | 1272 | 9900 | 689 |
394.5 | 336.4 | 19 | 720 | 15 | 175 | 125 | 1351 | 11970 | 799 |
465.4 | 397.5 | 19 | 783 | 15 | 175 | 125 | 1412 | 14040 | 892 |
559.5 | 477 | 19 | 858 | 20 | 175 | 125 | 1498 | 16920 | 1024 |
652.4 | 556.5 | 19 | 927 | 20 | 175 | 125 | 1567 | 19710 | 1141 |
Size (kcmil) |
Equivalent AAC (AWG or kcmil) |
Stranding | Conductor Diameter (mils) |
Covering Thickness (mils) | Cable O.D. (mils) |
Rated Strength (lbs) |
Weight per 1000 ft. (lbs) |
||
Conductor Shield | Inner Layer | Outer Layer | |||||||
48.69 | 4 | 7 | 250 | 15 | 175 | 125 | 880 | 1584 | 278 |
77.47 | 2 | 7 | 316 | 15 | 175 | 125 | 946 | 2520 | 333 |
123.3 | 1/0 | 7 | 398 | 15 | 175 | 125 | 1028 | 4014 | 411 |
155.4 | 2/0 | 7 | 447 | 15 | 175 | 125 | 1077 | 4851 | 462 |
195.7 | 3/0 | 7 | 502 | 15 | 175 | 125 | 1132 | 6111 | 523 |
246.9 | 4/0 | 7 | 563 | 15 | 175 | 125 | 1193 | 7704 | 598 |
312.8 | 266.8 | 19 | 642 | 15 | 175 | 125 | 1272 | 9900 | 689 |
394.5 | 336.4 | 19 | 720 | 15 | 175 | 125 | 1351 | 11970 | 799 |
465.4 | 397.5 | 19 | 783 | 15 | 175 | 125 | 1412 | 14040 | 892 |
559.5 | 477 | 19 | 858 | 20 | 175 | 125 | 1498 | 16920 | 1024 |
652.4 | 556.5 | 19 | 927 | 20 | 175 | 125 | 1567 | 19710 | 1141 |
Size (AWG or kcmil) | Stranding | Conductor Diameter (mils) | Covering Thickness (mils) | Cable O.D. (mils) | Rated Strength (lbs) | Weight per 1000 ft.(lbs) | ||
Conductor Shield | Inner Layer | Outer Layer | ||||||
1/0 | 7 | 336 | 15 | 175 | 125 | 966 | 1791 | 368 |
2/0 | 7 | 376 | 15 | 175 | 125 | 1006 | 2259 | 411 |
3/0 | 7 | 423 | 15 | 175 | 125 | 1053 | 2736 | 464 |
4/0 | 7 | 475 | 15 | 175 | 125 | 1105 | 3447 | 527 |
266.8 | 19 | 537 | 15 | 175 | 125 | 1167 | 4473 | 603 |
336.4 | 19 | 603 | 15 | 175 | 125 | 1233 | 5535 | 696 |
397.5 | 19 | 659 | 15 | 175 | 125 | 1289 | 6399 | 777 |
477 | 19 | 722 | 20 | 175 | 125 | 1362 | 7524 | 889 |
556.5 | 37 | 780 | 20 | 175 | 125 | 1420 | 8946 | 987 |
636 | 37 | 835 | 20 | 175 | 125 | 1475 | 10260 | 1085 |
795 | 37 | 932 | 20 | 175 | 125 | 1572 | 12510 | 1278 |