Customization: | Available |
---|---|
Application: | Construction, Underground, Industrial, Power Station |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of US$ 1/Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
0.6/1kv Copper Conductor Xlpe Insulated PVC Cable
1. Operating Characteristics
1). Standard: According to Chinese national standard GB 12706 and GB12666.6(Equal to IEC60502 and IEC60331),also can do by standard of ASTM,BS,GB,DIN and AS/NZS or other standards as request.
2). Rated Voltage:0.6/1KV
3). Construction:
Conductor:Copper or Aluminium
Insulation:PVC/XLPE
Inner sheath:PVC or PE
Armoured:Galvanized steel tape or galvanized steel wire
Outer Sheath:PVC or PE
NO. of cable cross: 1 core(Single core),2cores(Double cores),3cores, 4cores(4 equal-section-area cores OR 3 equal-section-area+1 small section area neutral core),5cores(5 3 equal-section-area cores+2 small area neutral cores OR 4 equal-section-area +1 small area neutral cores).We provide armored type and non-armored type for the cables stated above.
Also can do according to the customer's request.
4). Characters:
a.Max Long-time operating temperature of PVC insulated cable is 70°C
b.Installing temperature of cable should not be less than 0°C
c.Max short-circuit temperature is not exceed 160°C,Not more than5 Sec.
d.Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable)
2. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or in conduit, unable to bear external mechanical force.
3. Manufacturing Standards
IEC 60502-1 & Chinese national standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.
Core NO. & Nominal Cross-section Area as reference:
No. of Core |
1 |
2 |
3 |
3+1 |
4 |
3+2 |
4+1 |
Section Area (mm2) |
4~500 |
2.5~500 |
2.5~300 |
4~300 |
2.5~300 |
2.5~300 |
4~300 |
AWG | Cross Section | Insulation thickness | Minimum Sheath thickness | Maximum Overall diameter |
---|---|---|---|---|
mm2 | mm | mm | mm | |
16 | 1x1.5 | 0.7 | 1.09 | 6.6 |
14 | 1x2.5 | 0.7 | 1.09 | 7 |
12 | 1x4 | 0.7 | 1.09 | 7.6 |
10 | 1x6 | 0.7 | 1.09 | 8.2 |
8 | 1x10 | 0.7 | 1.09 | 9.2 |
6 | 1x16 | 0.7 | 1.09 | 10.5 |
4 | 1x25 | 0.9 | 1.09 | 12.5 |
2 | 1x35 | 0.9 | 1.09 | 13.5 |
1 | 1x50 | 1 | 1.09 | 15 |
2/0 | 1x70 | 1.1 | 1.09 | 17 |
3/0 | 1x95 | 1.1 | 1.18 | 19 |
4/0 | 1x120 | 1.2 | 1.18 | 21 |
300MCM | 1x150 | 1.4 | 1.26 | 23 |
500MCM | 1x185 | 1.6 | 1.26 | 25.5 |
750MCM | 1x240 | 1.7 | 1.35 | 28.5 |
1x300 | 1.8 | 1.43 | 31 | |
16 | 2x1.5 | 0.7 | 1.43 | 10.5 |
14 | 2x2.5 | 0.7 | 1.43 | 11.5 |
12 | 2x4 | 0.7 | 1.43 | 13 |
10 | 2x6 | 0.7 | 1.43 | 14 |
8 | 2x10 | 0.7 | 1.43 | 16 |
6 | 2x16 | 0.7 | 1.43 | 18.5 |
4 | 2x25 | 0.9 | 1.43 | 22 |
2 | 2x35 | 0.9 | 1.43 | 24.5 |
16 | 3x1.5 | 0.7 | 1.43 | 11 |
14 | 3x2.5 | 0.7 | 1.43 | 12.5 |
12 | 3x4 | 0.7 | 1.43 | 13.5 |
10 | 3x6 | 0.7 | 1.43 | 15 |
8 | 3x10 | 0.7 | 1.43 | 17 |
6 | 3x16 | 0.7 | 1.43 | 19.5 |
4 | 3x25 | 0.9 | 1.43 | 23.5 |
2 | 3x35 | 0.9 | 1.43 | 26 |
1 | 3x50 | 1 | 1.43 | 29 |
2/0 | 3x70 | 1.1 | 1.52 | 34 |
3/0 | 3x95 | 1.1 | 1.6 | 38.5 |
4/0 | 3x120 | 1.2 | 1.69 | 42.5 |
300MCM | 3x150 | 1.4 | 1.86 | 47.5 |
500MCM | 3x185 | 1.6 | 1.94 | 53 |
750MCM | 3x240 | 1.7 | 2.11 | 59.5 |
- | 3x300 | 1.8 | 2.28 | 66 |
16 | 4x1.5 | 0.7 | 1.8 | 11.3 |
14 | 4x2.5 | 0.7 | 1.8 | 12.2 |
12 | 4x4 | 0.7 | 1.8 | 13.3 |
10 | 4x6 | 0.7 | 1.8 | 15 |
8 | 4x10 | 0.7 | 1.8 | 17.25 |
6 | 4x16 | 0.7 | 1.8 | 18.8 |
4 | 4x25 | 0.9 | 1.8 | 23 |
2 | 4x35 | 0.9 | 1.8 | 25.1 |
1 | 4x50 | 1 | 1.9 | 29.1 |
2/0 | 4x70 | 1.1 | 2 | 33.9 |
3/0 | 4x95 | 1.1 | 2.1 | 38.4 |
4/0 | 4x120 | 1.2 | 2.3 | 42.4 |
300MCM | 4x150 | 1.4 | 2.4 | 47.2 |
500MCM | 4x185 | 1.6 | 2.6 | 52.65 |
750MCM | 4x240 | 1.7 | 2.8 | 59 |
- | 4x300 | 1.8 | 3 | 64.8 |
1 | 3x50+35 | 1 | 1.8 | 28.8 |
2/0 | 3x70+50 | 1.1 | 2 | 33.4 |
3/0 | 3x95+50 | 1.1 | 2.1 | 37 |
4/0 | 3x120+70 | 1.2 | 2.2 | 41.3 |
300MCM | 3x150+70 | 1.4 | 2.3 | 45.1 |
500MCM | 3x185+70 | 1.6 | 2.5 | 50 |
750MCM | 3x240+95 | 1.7 | 2.7 | 55.8 |
16 | 5x1.5 | 0.7 | 1.8 | 12.1 |
14 | 5x2.5 | 0.7 | 1.8 | 13.1 |
12 | 5x4 | 0.7 | 1.8 | 14 |
10 | 5x6 | 0.7 | 1.8 | 16.3 |
8 | 5x10 | 0.7 | 1.8 | 18.5 |
6 | 5x16 | 0.7 | 1.8 | 20.6 |
4 | 5x25 | 0.9 | 1.8 | 25.4 |
16 | 7x1.5 | 0.7 | 1.8 | 12.3 |
14 | 7x2.5 | 0.7 | 1.8 | 13.2 |
12 | 7x4 | 0.7 | 1.8 | 15.4 |
16 | 8x1.5 | 0.7 | 1.8 | 13.9 |
14 | 8x2.5 | 0.7 | 1.8 | 14.9 |
12 | 8x4 | 0.7 | 1.8 | 16.5 |
16 | 10x1.5 | 0.7 | 1.8 | 15.8 |
14 | 10x2.5 | 0.7 | 1.8 | 17 |
12 | 10x4 | 0.7 | 1.8 | 19 |
16 | 12x1.5 | 0.7 | 1.8 | 15.5 |
14 | 12x2.5 | 0.7 | 1.8 | 16.8 |
12 | 12x4 | 0.7 | 1.8 | 19.6 |
16 | 14x1.5 | 0.7 | 1.8 | 17 |
14 | 14x2.5 | 0.7 | 1.8 | 18.3 |
12 | 14x4 | 0.7 | 1.8 | 20.5 |
16 | 19x1.5 | 0.7 | 1.8 | 17.9 |
14 | 19x2.5 | 0.7 | 1.8 | 19.4 |
12 | 19x4 | 0.7 | 1.8 | 22.6 |
16 | 24x1.5 | 0.7 | 1.8 | 20.7 |
14 | 24x2.5 | 0.7 | 1.8 | 23.2 |
16 | 30x1.5 | 0.7 | 1.8 | 22.6 |
14 | 30x2.5 | 0.7 | 1.8 | 24.5 |
16 | 37x1.5 | 0.7 | 1.8 | 23.5 |
14 | 37x2.5 | 0.7 | 1.8 | 26.3 |
4.CE APPROVE
Please contact us for technical support with the right cable selection for your power distribution projects and to discuss your maintenance or project specific requirements. We provide tailored solutions for this cable range which include storage, cutting to length, and 2 days collection as standard.