Customization: | Available |
---|---|
Application: | Construction, Underground, Industrial, Power Station, Direct Burial Without Extra Mechanical Protection |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of US$ 1/Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
These cables are especially suitable for fixed installations that may be subject to mechanical aggression. They are highly recommended for use in installations in warehouses, production plants and agricultural facilities where the presence of rodents could imply a threat to cable integrity. At the same time, its use is recommended for street lighting installations. In some cases, these cables are used in those places where there is a potential explosion hazard such as petrol stations or flammable product warehouses.
UNE 21123-2, IEC 60502, EN 60332-1, IEC 60332-1
- Rigid electrolytic annealed copper conductor
- Class 1 (up to 4 mm2 ) or 2 (from 6 mm2 upwards) in accordance with IEC 60228
- Class 5 for (RVFV-K/VVFV-K) in accordance with IEC 60228
- XLPE insulation (RVFV/RVFV-K) or PVC insulation (VVFV/ VVFV-K) according to IEC 60502
- up to 5 conductors: by colors (RVFV/RVFV-K)
- 6 or more conductors: black numbered + green/yellow. (VVFV/VVFV-K)
- Extruded continuous PVC bedding type ST1/ST2 of standard IEC 60502.
- Double steel or aluminum tape armour
- Flexible PVC compound outer sheath type ST1/ST2 of standard IEC 60502
Conductor: | : rigid red copper / Aluminum wire, class 1 (Φ ≤ 4 mm²) stranded circular compacted copper / Aluminum class 2 (Φ>4mm²) |
Insulation | : XLPE crosslinked polyethylene (no dry cool) |
Outer sheath | : PVC |
Screen | : no |
Drain wire | : no |
Lead sheath | : no |
Concentric cond. | : none |
Insulation integrity | : no |
Circuit integrity | : no |
Armouring | : Steel Tape Armoured / Aluminum Tape Armoured |
U-1000 RVFV & VVFV / RVFV-K & VVFV-K Cable - Technical data and tests | |
Standards | : NF C 32-322 |
Nominal voltage U0/U | : 0,6/1 kV |
Test voltage (50 Hz) | : 4 kV |
Maximun voltage Um | : 1,2 kV |
Maximun operating temperature | : +90° C |
Maximun short circuit temperature | : +250° C |
Min. operating temperature (without mechanical shocks) |
: -25° C |
Minimum installation and use temp. | : -10° C |
Minimum bending radius per D cable diameter (in mm) |
: 6 x D |
Core colours | single core : black two cores : blue-brown three cores : brown-black-blue (1,5/2,5 mmq); brown-black-gray (4 mmq) or Y/G-blue-brown) four cores : blue-brown-black-gray (or Y/G instead blue) five cores : blue-brown-black-gray-Y/G (or black instead Y/G) |
Sheath colour | : black |
AWG | NO. OF CORES X NOMINAL CROSS SECTIONAL AREA # X MM² |
NOMINAL OVERALL DIAMETER MM |
NOMINAL WEIGHT KG/KM |
AWG | NO. OF CORES X NOMINAL CROSS SECTIONAL AREA # X MM² |
NOMINAL OVERALL DIAMETER MM |
NOMINAL WEIGHT KG/KM |
6 | 1×16 | 14.4 | 345 | 3/0 | 3×95/50 | 41.3 | 4613 |
4 | 1×25 | 16 | 477 | 4/0 | 3×120/70 | 46.9 | 6,023 |
2 | 1×35 | 17.3 | 582 | 300MCM | 3×150/70 | 54.7 | 7455 |
1 | 1×50 | 18.5 | 722 | 350MCM | 3×185/95 | 55.1 | 8890 |
2/0 | 1×70 | 20.7 | 962 | 500MCM | 3×240/120 | 62.5 | 11055 |
3/0 | 1×95 | 22.1 | 1173 | 16 | 4×1.5 | 13.2 | 275 |
4/0 | 1×120 | 24.6 | 1522 | 14 | 4×2.5 | 14.4 | 339 |
300MCM | 1×150 | 26.5 | 1821 | 12 | 4×4 | 15.1 | 419 |
350MCM | 1×185 | 28.5 | 2230 | 10 | 4×6 | 17.3 | 545 |
500MCM | 1×240 | 31.7 | 2,35 | 8 | 4×10 | 19.8 | 770 |
16 | 2×1.5 | 12.3 | 227 | 6 | 4×16 | 22.3 | 1062 |
14 | 2×2.5 | 12.8 | 259 | 4 | 4×25 | 26.5 | 1602 |
12 | 2×4 | 13.6 | 311 | 16 | 5×1.5 | 14.4 | 320 |
10 | 2×6 | 15.8 | 411 | 14 | 5×2.5 | 15.3 | 390 |
8 | 2×10 | 17.8 | 552 | 12 | 5×4 | 17.2 | 509 |
6 | 2×16 | 19.6 | 726 | 10 | 5×6 | 18.8 | 640 |
16 | 3×1.5 | 12.8 | 252 | 8 | 5×10 | 21.3 | 909 |
14 | 3×2.5 | 13.3 | 293 | 6 | 5×16 | 25.2 | 1304 |
12 | 3×4 | 14.5 | 367 | 16 | 6×1.5 | 15.8 | 394 |
10 | 3×6 | 16.3 | 468 | 16 | 7×1.5 | 15.8 | 412 |
8 | 3×10 | 18.3 | 641 | 16 | 10×1.5 | 17.8 | 521 |
6 | 3×16 | 20.4 | 870 | 16 | 12×1.5 | 19.2 | 603 |
6 | 3×16/10 | 21.5 | 996 | 16 | 16×1.5 | 20.8 | 714 |
4 | 3×25/16 | 25.1 | 1468 | 16 | 19×1.5 | 21.8 | 792 |
2 | 3×35/16 | 27.9 | 1854 | 16 | 24×1.5 | 23.3 | 914 |
1 | 3×50/25 | 29.6 | 2101 | 16 | 27×1.5 | 25.4 | 1015 |
2/0 | 3×70/35 | 37.8 | 3683 |
FAQ