Customization: | Available |
---|---|
Application: | Construction, Overhead, Industrial, Power Station |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of US$ 0/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
APPLICATIONS
YKYzo 0,6/1 kV and YKY 0,6/1 kV power cables are designed for electric power transmission. They are also applied in power circuits in industrial plants and power stations and in local distribution networks.
The cables are suitable for indoor and outdoor installations, for laying in cable ducts and for direct earth burial.
CONSTRUCTION
- bare annealed copper conductors meeting requirements of PN-EN 60228 standard:
RE - class 1 circular single-wire,
RM - class 2 circular multi-wire,
SM - class 2 sector shaped multi-wire,
- PVC insulation - colours in accordance with PN-HD 308 standard, green-yellow protective conductor in YKYzo 0,6/1 kV cable,
- insulated conductors laid-up in a cable core,
- black PVC cable sheath, other colours also available.
AVAILABLE UPON REQUEST
YKYzo-O 0,6/1 kV and YKY-O 0,6/1 kV - cables designed for frequent contact with petroleum products, as in petrol stations and stores, where engine fuels and lubricants are pumped or handled. The cable sheath is then made of special PVC compound meeting oil resistance requirements of Polish standard PN-EN 60811-404.
XnKXSzo 0,6/1 kV and XnKXS 0,6/1 kV - halogen free cables, applied when higher safety in case of fire is required. The cables are flame retardant, their smoke emission in fire is low and released gases are not corrosive.
Steel wire or steel tape armoured cables as above applied in locations where enhanced protection against mechanical damages is required.
CHARACTERISTICS
Operating voltage Uo/U 0.6/1 kV
Voltage test 4 kV rms
Insulation resistance, minimum 20 MΩ·km
Conductor temperature limit
in work conditions +70°C
in short-circuit +160°C
Temperature range
during operation from - 30 to + 70°C
during installation from - 5 to + 50°C
Minimum bending radius
single wire cables 15 x cable diameter
multi wire cables 12 x cable diameter
Cable combustibility flame retardant
Combustibility tests PN-EN 60332-1-2, IEC 60332-1-2
Reference standards IEC 60502-1, PN-93/E-90401, PN-HD 603 S1
Cable Parameter
Description | Number of conductors x conductor crosssection (in mm2) |
Cable outer diameter (appr. in mm) |
Copper index (kg/km) |
Cable weight (appr. in kg/km) |
YKY 0,6/1 kV | 3x1,0 RE | 8,3 | 28.8 | 110 |
YKY 0,6/1 kV | 5x1,0 RE | 9,6 | 48 | 153 |
YKY 0,6/1 kV | 3x1,5 RE | 8,8 | 43.2 | 132 |
YKY 0,6/1 kV | 5x1,5 RE | 10,3 | 72 | 188 |
YKY 0,6/1 kV | 4x2,5 RE | 10,4 | 96 | 205 |
YKY 0,6/1 kV | 2x1,0 RE | 7,9 | 19.2 | 96 |
YKY 0,6/1 kV | 4x1,0 RE | 8,9 | 38.4 | 129 |
YKY 0,6/1 kV | 2x1,5 RE | 8,4 | 28.8 | 113 |
YKY 0,6/1 kV | 3x2,5 RE | 9,6 | 72 | 170 |
YKY 0,6/1 kV | 5x10 RE | 17,6 | 480 | 746 |
YKY 0,6/1 kV | 2x2,5 RE | 9,2 | 48 | 144 |
YKY 0,6/1 kV | 2x10 RE | 14 | 192 | 399 |
YKY 0,6/1 kV | 5x25 RM | 25,8 | 1200 | 1679 |
YKY 0,6/1 kV | 5x35 RM | 28,8 | 1680 | 2215 |
YKY 0,6/1 kV | 4x50 SM | 27,1 | 1920 | 2300 |
YKY 0,6/1 kV | 5x2,5 RE | 11,3 | 120 | 249 |
YKY 0,6/1 kV | 4x4 RE | 12,5 | 153.6 | 309 |
YKY 0,6/1 kV | 5x6 RE | 15 | 288 | 489 |
YKY 0,6/1 kV | 5x16 RE | 20,1 | 768 | 1071 |
YKY 0,6/1 kV | 4x10 RE | 16,1 | 384 | 615 |
YKY 0,6/1 kV | 4x16 RE | 18,3 | 614.4 | 877 |
YKY 0,6/1 kV | 4x1,5 RE | 9,5 | 57.6 | 157 |
YKY 0,6/1 kV | 5x4 RE | 13,6 | 192 | 372 |
YKY 0,6/1 kV | 3x4 RE | 11,5 | 115.2 | 252 |
YKY 0,6/1 kV | 1x35 RM | 11,6 | 336 | 406 |
YKY 0,6/1 kV | 5x50 RM | 33,2 | 2400 | 3002 |
YKY 0,6/1 kV | 4x25 RM | 23,3 | 960 | 1365 |
YKY 0,6/1 kV | 4x6 RE | 13,7 | 230.4 | 403 |
YKY 0,6/1 kV | 4x35 RM | 26 | 1344 | 1798 |
YKY 0,6/1 kV | 1x25 RM | 10,6 | 240 | 311 |
YKY 0,6/1 kV | 1x120 RM | 19 | 1152 | 1271 |
YKY 0,6/1 kV | 1x240 RM | 26,1 | 2304 | 2554 |
YKY 0,6/1 kV | 1x150 RM | 20,9 | 1440 | 1579 |
YKY 0,6/1 kV | 1x50 RM | 13,4 | 480 | 551 |
YKY 0,6/1 kV | 1x70 RM | 15 | 672 | 752 |
YKY 0,6/1 kV | 2x16 RE | 15,8 | 307.2 | 552 |
YKY 0,6/1 kV | 1x185 RM | 23,3 | 1776 | 1967 |
YKY 0,6/1 kV | 3x16 RE | 16,7 | 460.8 | 697 |
YKY 0,6/1 kV | 3x10 RE | 14,8 | 288 | 495 |
YKY 0,6/1 kV | 1x10 RE | 7,7 | 96 | 147 |
YKY 0,6/1 kV | 1x16 RE | 8,6 | 153.6 | 207 |
YKY 0,6/1 kV | 3x6 RE | 12,6 | 172.8 | 326 |
YKY 0,6/1 kV | 1x10 RM | 8 | 96 | 153 |
YKY 0,6/1 kV | 3x50 RM | 27 | 1440 | 1908 |
YKY 0,6/1 kV | 3x25 RM | 21 | 720 | 1073 |
YKY 0,6/1 kV | 1x95 RM | 17,3 | 912 | 1068 |
YKY 0,6/1 kV | 2x4 RE | 10,9 | 76.8 | 209 |
YKY 0,6/1 kV | 2x6 RE | 11,9 | 115.2 | 265 |
YKY 0,6/1 kV | 2x35 RM | 21,8 | 672 | 1092 |
YKY 0,6/1 kV | 1x1,5 RE | 5,2 | 14.4 | 46 |
YKY 0,6/1 kV | 1x6 RE | 6,9 | 57.6 | 104 |
YKY 0,6/1 kV | 2x25 RM | 19,7 | 480 | 846 |
YKY 0,6/1 kV | 1x300 RM | 28,5 | 2880 | 3117 |
YKY 0,6/1 kV | 1x400 RM | 31,7 | 3840 | 4213 |
YKY 0,6/1 kV | 1x500 RM | 35,1 | 4800 | 5251 |
YKY 0,6/1 kV | 1x1,0 RE | 4,9 | 9.6 | 39 |
YKY 0,6/1 kV | 1x2,5 RE | 5,5 | 24 | 58 |
YKY 0,6/1 kV | 1x4 RE | 6,4 | 38.4 | 81 |
YKY 0,6/1 kV | 2x50 RM | 25,1 | 960 | 1472 |
YKY 0,6/1 kV | 2x70 RM | 28,8 | 1344 | 2020 |
Henan Hongda Cable Co., Ltd. located in No. 3, Changping Road, ZhanDian District, Jiaozuo, Wuzhi. Our factroy established in March of 2004. Our owns registered capital of RMB Fifty-one million six hundred and eighty thousand. Hongda Cable covers an area of 100,000 square meters, including 50,000 square meters of building area. We have more than 120 staff members and professional workers. our fixed assets of 90,000,000. We can provide more than 100 varieties, tens of thousands of specifications of wire and cable, with 10000 km annual production capacity
Henan Hongda Cable Co. Ltd. is the original Zhengzhou Hongda Cable Co. Ltd. established enterprise expansion. The company is committed to system R&D, design, manufacturing, marketing and service of cable products,We mainly aim at managing cross-linking XLPE insulated power cables, PVC insulated power cables, plastic insulated control cables, insulated overhead cables, and stranded aluminum and ACSR. At present, the cables' biggest cross area is 800 square meters with a maximum electric power of 35KV. The company has more than 300 (sets) domestic and oversea-leading production and testing equipment
Our factory has advanced equipment of 20 sets production lines and 25 sets testing machinas, The production capacity is more than 12 million kilometers. We have skillful staff over 20-year experience,before starting working, every worker need to be trained professionally. Therefore, we can promise the product will be 100% quantified.
In our factory, every roll wire need to be test strictly, We wil test resistance, insulation thickness, the tension, stretch and so on. Before packing, every cable need to be test quantified, and we can make promise the 100% quantified.
Why Choose Us ?
1. We have a large production base, and advanced production equipment
2. Have an competitive price and high quality
3. Excellent after-sale service
4. Free issue:packaging list,invoice
5. Powerful technology team
6. Strict quality assurance system and perfect testing means
7. Advanced process equipment
8. Delivery on time
9. Our cable sales to Middle East,Africa,Russia,Southeast Asia, etc.
10.We have a good reputation in the overseas