Customization: | Available |
---|---|
Application: | Construction, Underground, Industrial, Power Station |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of US$ 0/Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Category: Power Cable.
Tags: NYY, NAYY, AYY, A2XY, Power, PVC, XLPE.
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
- Single or multiple Aluminum / copper
- Solid strand to VDE-0295 Class-1 - For #4 AWG and up, VDE-0295 Class-2 strand
- PVC core insulation - Color code to VDE-0293-308 with ground - Above 5 cores, color is black w/ white numbers
- PVC (DMV5) outer jacket - Black (RAL 9005)
- Working voltage: 600/1000 volts
- Test voltage: 4000 volts
- Flexing bending radius: 15 x Ø
- Static bending radius: 12 x Ø
- Flexing temp: -5º C to +50º C
- Static temp: -40º C to +70º C
- Flame retardant: IEC 60332.1
- Insulation resistance: > 100 MΩ x km
Conductor | Inductance | Current - Carrying
Capacity at 30° C * |
Short circuit
current at 1 sec |
|||
Nom. Cross
Section Area |
DC Resistance
at 20°C |
AC Resistance
at 70°C |
||||
in air | in ground | |||||
(mm²) | Max. (Ω/km) | Max. (Ω/km) | (mH/km) | Max. (A) | Max. (A) | Max. (kA) |
10 | 3.08 | 3.701 | 0.269 | 53 | 59 | 0.76 |
16 | 1.91 | 2.295 | 0.253 | 71 | 77 | 1.22 |
25 | 1.20 | 1.442 | 0.257 | 93 | 99 | 1.90 |
35 | 0.868 | 1.043 | 0.247 | 115 | 119 | 2.66 |
50 | 0.641 | 0.770 | 0.247 | 134 | 135 | 3.80 |
70 | 0.443 | 0.533 | 0.238 | 167 | 165 | 5.32 |
95 | 0.320 | 0.385 | 0.238 | 207 | 198 | 7.22 |
120 | 0.253 | 0.305 | 0.233 | 240 | 225 | 9.12 |
150 | 0.206 | 0.248 | 0.235 | 277 | 254 | 11.40 |
185 | 0.164 | 0.198 | 0.233 | 316 | 286 | 14.06 |
240 | 0.125 | 0.152 | 0.232 | 377 | 332 | 18.24 |
300 | 0.100 | 0.122 | 0.231 | 433 | 376 | 22.80 |
Nominal Cross Sectional Area (Sq. mm) |
Nominal Thickness of Insulation (mm) |
Nominal Thicknessof Outer Sheath (mm) |
Approx.Overall Diameter(mm) | Approx. Net Wt. of Cable (kg/km) | |
AL Cable A2XY | CU Cable 2XY | ||||
1x16 | 0.7 | 1.8 | 11 | 125 | 225 |
1x25 | 0.9 | 1.8 | 12 | 170 | 330 |
1x35 | 0.9 | 1.8 | 13 | 205 | 425 |
1x50 | 1.0 | 1.8 | 15 | 250 | 550 |
1x70 | 1.1 | 1.8 | 16 | 335 | 750 |
1x95 | 1.1 | 1.8 | 18 | 425 | 1000 |
1x120 | 1.2 | 1.8 | 20 | 515 | 1250 |
1x150 | 1.4 | 2.0 | 22 | 615 | 1520 |
1x185 | 1.6 | 2.0 | 24 | 770 | 1880 |
1x240 | 1.7 | 2.0 | 27 | 965 | 2415 |
1x300 | 1.8 | 2.0 | 30 | 1160 | 2980 |
1x400 | 2.0 | 2.2 | 33 | 1480 | 3800 |
1x500 | 2.2 | 2.2 | 36 | 1840 | 4815 |
1x630 | 2.4 | 2.2 | 40 | 2350 | 6150 |
1x800 | 2.6 | 2.4 | 47 | 2830 | 7840 |
1x1000 | 2.8 | 2.6 | 51 | 3670 | 9800 |
Nominal Cross Sectional Area (Sq. mm) |
Nominal Thickness of Insulation (mm) |
Minimum Thickness of Inner Sheath(mm) | Nominal Thickness of Outer Sheath (mm) |
Approx.Overall Diameter(mm) | Approx. Net Wt. of Cable (kg/km) | |
AL Cable A2XY | CU Cable 2XY | |||||
3×25+16 | 0.9/0.7 | 0.3 | 2.0 | 22 | 575 | 1125 |
3×35+16 | 0.9/0.7 | 0.3 | 2.0 | 24 | 685 | 1425 |
3×50+25 | 1.0/0.9 | 0.3 | 2.0 | 27 | 880 | 1980 |
3×70+35 | 1.1/0.9 | 0.4 | 2.2 | 31 | 1185 | 2680 |
3×95+50 | 1.1/1.0 | 0.4 | 2.2 | 34 | 1480 | 3580 |
3×120+70 | 1.2/1.1 | 0.4 | 2.2 | 38 | 1880 | 4480 |
3×150+70 | 1.4/1.1 | 0.5 | 2.4 | 43 | 2275 | 5485 |
3×185+95 | 1.6/1.1 | 0.5 | 2.6 | 46 | 2770 | 6785 |
3×240+120 | 1.7/1.2 | 0.6 | 2.8 | 52 | 3580 | 8675 |
3×300+150 | 1.8/1.4 | 0.6 | 3.0 | 57 | 4380 | 10780 |
3×400+185 | 2.0/1.6 | 0.7 | 3.4 | 65 | 5580 | 13980 |
3×500+240 | 2.2/1.7 | 0.7 | 3.6 | 73 | 6980 | 17425 |
3×630+300 | 2.4/1.8 | 0.7 | 4.0 | 82 | 8885 | 21970 |
Nominal Cross Sectional Area (Sq. mm) |
Nominal Thickness of Insulation (mm) |
Minimum Thickness of Inner Sheath(mm) | Nominal Thicknessof Outer Sheath (mm) |
Approx.Overall Diameter(mm) | Approx. Net Wt. of Cable (kg/km) | |
AL Cable A2XY | CU Cable 2XY | |||||
4x4 | 0.7 | 0.3 | 1.8 | 16 | 225 | 340 |
4x6 | 0.7 | 0.3 | 1.8 | 17 | 315 | 480 |
4x10 | 0.7 | 0.3 | 1.8 | 19 | 370 | 640 |
4x16 | 0.7 | 0.3 | 1.8 | 20 | 440 | 840 |
4x25 | 0.9 | 0.3 | 2.0 | 24 | 650 | 1290 |
4x35 | 0.9 | 0.3 | 2.0 | 26 | 780 | 1685 |
4x50 | 1.0 | 0.3 | 2.0 | 29 | 985 | 2190 |
4x70 | 1.1 | 0.4 | 2.2 | 34 | 1380 | 3090 |
4x95 | 1.1 | 0.4 | 2.2 | 37 | 1685 | 3980 |
4x120 | 1.2 | 0.5 | 2.4 | 41 | 2125 | 5130 |
4x150 | 1.4 | 0.5 | 2.6 | 45 | 2630 | 6230 |
4x185 | 1.6 | 0.5 | 2.8 | 50 | 3230 | 7830 |
4x240 | 1.7 | 0.6 | 3.0 | 56 | 4080 | 9980 |
4x300 | 1.8 | 0.7 | 3.2 | 63 | 5030 | 12030 |
4x400 | 2.0 | 0.7 | 3.6 | 70 | 6385 | 15980 |
4x500 | 2.2 | 0.7 | 3.8 | 79 | 7980 | 19985 |
4x630 | 2.4 | 0.7 | 4.0 | 88 | 9985 | 25985 |
Steel wooden drum (fumigation)
Cable length in each drum: 500m/1000m or as per actual cable length requirements.