• Na2X2y Na2xs (FL) 2y
  • Na2X2y Na2xs (FL) 2y

Na2X2y Na2xs (FL) 2y

Application: Construction, Underground, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Current: AC Cable
Insulation Material: XLPE
Material Shape: Round Wire
Certification: ISO, CCC, CE, RoHS
Customization:

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Armour
Non
Conductor Material
Copper/Aluminum
Standard
VDE 0482-332-1-2, DIN En 60332-1-2 / IEC 60332-1
Quality Guarantee
Ten Years
Core
1core/Three Cores
Insulated Color
as Your Requirement
Sheath Color
Black
Screen
Copper Wires
Manufacture
Yes
Transport Package
Wooden Drum
Specification
12/20 KV 1X95/50mm2
Trademark
Hongda
Origin
China, Henan
HS Code
8544492100
Production Capacity
1000km/Per Months

Product Description

European Medium Voltage Power Cable: NA2XSY/N2XSY    6/10 kV, 12/20 kV, 18/30 kV

Na2X2y Na2xs (FL) 2y
Na2X2y Na2xs (FL) 2y

 

Application  

Suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switch boards and power stations. Due to the good laying characteristic, this cable can also be installed in difficult in difficult line guide ways.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures a construction free of partial discharges with high operational reliabilities.

Technical Data European 
  • XLPE-insulated power cables to DIN VDE 0276 part 620, HD 620 S1 and IEC 60502
  • Temperature Range
    During installation up to -5°C/+23°F
  • Operating Temperature
    Max. +90°C/+194°F
  • Short Circuit Temperature +250°C/+482°F
    (Short circuit duration up to 5 sec.)
  • Nominal Voltages
    U0/U 6/10 kV, 12/20 kV, 18/30 kV
  • Operating Voltages for
    6/10 kV = max. 12 kV
    12/20 kV = max. 24 kV
    18/30 kV = max. 36 kV
  • Test Voltages for
    6/10 kV = 15 kV
    12/20 kV = 30 kV
    18/30 kV = 45 kV
  • Minimum Bending Radius
    During installation max. 15x cable Ø
  • Power Ratings Table
    See Technical Information
Code-Designation for Power Cables with PVC or XLPE Insulation
Design Identification of Design  Explanations
Conductor N According to VDE Standard
(No abbreviation for copper conductor)
A Aluminum conductors
Y Insulation of thermoplastic Polyvinyl chloride (PVC)
2X Insulation cross-linked Polyethylene (XLPE)
Concentric Conductor, Shielding  C Concentric conductors of copper wires and copper tape, helically wounded
CW Concentric conductors of copper wires in wave conal formation and and copper tape, helically wounded
CE Concentric conductors of copper wires and copper tape over each individual conductor, helically wounded
Shielding S Shielding of copper wires and copper tape, helically wounded
SE Shielding of copper wires and copper tape over each individual conductor, helically wounded
(F) Longitudinally water-proof shielding
Armor B Armor of steel tape
F Armor of galvanized flat steel wires
G Counter helix of galvanized steel tape
Jacket K Lead jacket
Outer Jacket  Y PVC jacket
2Y PE jacket
Cable for U0/U 0.6/1 kV are additionally designated with
  -J Cables with green-yellow (green-natural) conductor are marked with protective conductor
-O Cables without green-yellow (green-natural) conductor are marked without protective conductor
 
Cable Construction  
  • Circular bare aluminum-conductor of stranded wires to HD 383
  • Inner semi-conducting coating
  • Conductor insulation of cross-linked Polyethylene (XLPE), PE-compound DIX8 to HD 620.1
  • Outer extrusion of semi-conducting coating spliced with the insulation
  • Wrapping of conductive material
  • Shield: Braiding of copper wires with one or two tapes applied helically
  • Wrapping
  • PVC outer jacket, compound DMV6 to HD 620.1
  • Jacket color: Red


 

Nominal Voltage 
 
6/10 kV
 
12/20 kV
 
18/30 kV
Description & No. Conductors x cross-sec. mm2, Nominal Voltage Operation Voltage max. Insul. Thick-ness mm Jacket Thick-ness mm Outer
Dia. min.-max.
Copper Weight
kg/km
Alu weight kg/km Weight ca. kg/km AWG
NA2XSY 6/10kV 1X50 rm/16 12 3.4 2.5 24.0 - 29.0 182.0 145.0 780.0 1
NA2XSY 6/10kV 1X70 rm/16 12 3.4 2.5 26.0 - 31.0 182.0 203.0 875.0 2/0
NA2XSY 6/10kV 1X95 rm/16 12 3.4 2.5 27.0 - 32.0 182.0 276.0 990.0 3/0
NA2XSY 6/10kV 1X120 rm/16 12 3.4 2.5 29.0 - 34.0 182.0 348.0 1110.0 4/0
NA2XSY 6/10kV 1X150 rm/16 12 3.4 2.5 30.0 - 35.0 182.0 435.0 1240.0 300 kcmil
NA2XSY 6/10kV 1X150 rm/25 12 3.4 2.5 30.0 - 35.0 283.0 435.0 1310.0 300 kcmil
NA2XSY 6/10kV 1X185 rm/25 12 3.4 2.5 32.0 - 37.0 283.0 537.0 1460.0 350 kcmil
NA2XSY 6/10kV 1X185 rm/16 12 3.4 2.5 32.0 - 37.0 182.0 537.0 1405.0 350 kcmil
NA2XSY 6/10kV 1X240 rm/25 12 3.4 2.5 34.0 - 39.0 283.0 696.0 1660.0 500 kcmil
NA2XSY 6/10kV 1X240 rm/16 12 3.4 2.5 34.0 - 39.0 182.0 696.0 1615.0 500 kcmil
NA2XSY 6/10kV 1X300 rm/25 12 3.4 2.5 36.0 - 41.0 283.0 870.0 1910.0 600 kcmil
NA2XSY 6/10kV 1X400 rm/35 12 3.4 2.5 40.0 - 45.0 394.0 1160.0 2315.0 750 kcmil
NA2XSY 6/10kV 1X500 rm/35 12 3.4 2.5 43.0 - 48.0 394.0 1450.0 2750.0 1000 kcmil
 
NA2XSY 12/20kV 1X50 rm/16 24 5.5 2.5 28.0 - 33.0 182.0 145.0 950.0 1
NA2XSY 12/20kV 1X70 rm/16 24 5.5 2.5 30.0 - 35.0 182.0 203.0 1110.0 2/0
NA2XSY 12/20kV 1X95 rm/16 24 5.5 2.5 31.0 - 36.0 182.0 276.0 1220.0 3/0
NA2XSY 12/20kV 1X120 rm/16 24 5.5 2.5 33.0 - 38.0 182.0 348.0 1310.0 4/0
NA2XSY 12/20kV 1X150 rm/16 24 5.5 2.5 34.0 - 39.0 182.0 435.0 1460.0 300 kcmil
NA2XSY 12/20kV 1X150 rm/25 24 5.5 2.5 34.0 - 39.0 283.0 435.0 1520.0 300 kcmil
NA2XSY 12/20kV 1X185 rm/16 24 5.5 2.5 36.0 - 41.0 182.0 537.0 1660.0 350 kcmil
NA2XSY 12/20kV 1X185 rm/25 24 5.5 2.5 36.0 - 41.0 283.0 537.0 1720.0 350 kcmil
NA2XSY 12/20kV 1X240 rm/25 24 5.5 2.5 39.0 - 44.0 283.0 696.0 1910.0 500 kcmil
NA2XSY 12/20kV 1X240 rm/16 24 5.5 2.5 39.0 - 44.0 182.0 696.0 1860.0 500 kcmil
NA2XSY 12/20kV 1X300 rm/25 24 5.5 2.5 41.0 - 46.0 283.0 870.0 2220.0 600 kcmil
NA2XSY 12/20kV 1X400 rm/35 24 5.5 2.5 44.0 - 49.0 394.0 1160.0 2620.0 750 kcmil
NA2XSY 12/20kV 1X500 rm/35 24 5.5 2.5 47.0 - 52.0 394.0 1450.0 3030.0 1000 kcmil
 
Description & No. Conductors x cross-sec. mm2, Nominal Voltage Operation Voltage max. Insul. Thick-ness mm Jacket Thick-ness mm Outer
Dia. min.-max.
Copper Weight
kg/km
Alu weight kg/km Weight ca. kg/km AWG
NA2XSY 18/30kV 1X50 rm/16 36 8.0 2.5 33.0 - 38.0 182.0 145.0 1260.0 1
NA2XSY 18/30kV 1X70 rm/16 36 8.0 2.5 35.0 - 40.0 182.0 203.0 1360.0 2/0
NA2XSY 18/30kV 1X95 rm/16 36 8.0 2.5 36.0 - 41.0 182.0 276.0 1510.0 3/0
NA2XSY 18/30kV 1X120 rm/16 36 8.0 2.5 38.0 - 43.0 182.0 348.0 1610.0 4/0
NA2XSY 18/30kV 1X150 rm/25 36 8.0 2.5 39.0 - 44.0 283.0 435.0 1810.0 300 kcmil
NA2XSY 18/30kV 1X150 rm/16 36 8.0 2.5 39.0 - 44.0 182.0 435.0 1760.0 300 kcmil
NA2XSY 18/30kV 1X185 rm/16 36 8.0 2.5 41.0 - 46.0 182.0 537.0 1960.0 350 kcmil
NA2XSY 18/30kV 1X185 rm/25 36 8.0 2.5 41.0 - 46.0 283.0 537.0 2020.0 350 kcmil
NA2XSY 18/30kV 1X240 rm/25 36 8.0 2.5 43.0 - 48.0 283.0 696.0 2260.0 500 kcmil
NA2XSY 18/30kV 1X240 rm/16 36 8.0 2.5 43.0 - 48.0 182.0 696.0 2210.0 500 kcmil
NA2XSY 18/30kV 1X300 rm/25 36 8.0 2.5 46.0 - 51.0 283.0 870.0 2560.0 600 kcmil
NA2XSY 18/30kV 1X400 rm/35 36 8.0 2.5 49.0 - 54.0 394.0 1160.0 2960.0 750 kcmil
NA2XSY 18/30kV 1X500 rm/35 36 8.0 2.6 52.0 - 57.0 394.0 1450.0 3460.0 1000 kcmil
   Na2X2y Na2xs (FL) 2y 

Na2X2y Na2xs (FL) 2y


 



Packaging&Delivery.
 Na2X2y Na2xs (FL) 2y



Packaging Details:
Wooden drums,steel wooden drums or as your requirement
Delivery Time:Normally within 30 days(detailly depend on the order quantity)

Contact us
Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software. Get price within 5 mins
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now