U-1000 AR2V industrial rigid unarmoured Low voltage aluminium power cable
Conductor: |
: Rigid Aluminum wire, class 1 (Φ ≤ 4 mm²)
stranded circular compacted Aluminum class 2 (Φ>4mm²) |
Insulation |
: XLPE crosslinked polyethylene (no dry cool) |
Outer sheath |
: PVC |
U-1000 R2V - Technical data and tests |
Standards |
: NF C 32-321 C32-321/A1; IEC 60502-1 NF EN 60332-1-2; NF C 15-100 |
Nominal voltage U0/U |
: 0,6/1 kV |
Test voltage (50 Hz) |
: 4 kV |
Maximun voltage Um |
: 1,2 kV |
Maximun operating temperature |
: +90° C |
Maximun short circuit temperature |
: +250° C |
Min. operating temperature
(without mechanical shocks) |
: -25° C |
Minimum installation and use temp. |
: -10° C |
Minimum bending radius per
D cable diameter (in mm) |
: 6 x D |
Maximum pulling stress |
: 5 kg/mm² (of copper cross section) |
Sheath colour |
: black |
NEW CORES IDENTIFICATION
Core identification in accordance with HD 308 S2 - Identification of cores in cables and flexible cords.
Number of cores |
HD 308 S2 since january 2004 |
G (earth core) |
X (without earth core) |
1 |
|
Black (preferential) |
2 |
|
Blue + Brown |
3* |
Green - Yellow + Blue + Brown |
Brown + Black + Grey |
3** |
|
Blue + Brown + Black |
4 |
Green - Yellow + Brown + Black + Grey |
Blue + Brown + Black + Grey |
5 |
Green - Yellow + Blue + Brown + Black + Grey |
Blue + Brown + Black + Grey + Black |
> 5 |
White printed numbers + 1 Green - Yellow |
White printed numbers |
* For the cables without Green/Yellow with a cross-section >4mm² |
** For the cables without Green/Yellow with a cross-section of 1,5mm² & 2,5mm² |
U-1000 AR2V Cable - Applications
This cable is for use on industrial sites and the upright columns of buildings. Particularly suited in cases of high operating temperatures and when high resistance to solar radiation and atmospheric agents is required.
Presents good resistance to low temperatures and chemical agents. It can be used without additional mechanical protection in open air, fixed to walls or in raceways, inside walkways, and in empty in constructions in general.
It can be laid underground with mechanical protection constucted from slabs, tiles, or bricks. It is not recommended to lay this cable in ground flooded for more than two months per year.
With appropriate mechanical protection it can be use in areas subject to risk of explosion, but in this case the permitted current load is reduced by 15%.
U-1000 AR2V Cable - Other standards |
German |
: NA2XY |
British |
: CU/XLPE/PVC |
Serbian |
: XP 00 |
Turkish |
: YXV-U (-R) |
Romanian |
: C2XY |
U-1000 AR2V
Low Voltage Power Cable (0.6/1 kV)
XLPE insulated, aluminum conductor, PVC outer sheath cable
AWG |
Cross Section |
Insulation thickness |
Minimum Sheath thickness |
Maximum Overall diameter |
Approx Cable weight kg/km |
|
mm^2 |
mm |
mm |
mm |
Al |
2 |
1x35 |
0.9 |
1.09 |
13.5 |
190 |
1 |
1x50 |
1 |
1.09 |
15 |
245 |
2/0 |
1x70 |
1.1 |
1.09 |
17 |
325 |
3/0 |
1x95 |
1.1 |
1.18 |
19 |
425 |
4/0 |
1x120 |
1.2 |
1.18 |
21 |
520 |
300MCM |
1x150 |
1.4 |
1.26 |
23 |
630 |
500MCM |
1x185 |
1.6 |
1.26 |
25.5 |
780 |
750MCM |
1x240 |
1.7 |
1.35 |
28.5 |
990 |
- |
1x300 |
1.8 |
1.43 |
31 |
1210 |
- |
1x400 |
2 |
1.52 |
34.2 |
1510 |
- |
1x500 |
2.2 |
1.6 |
38 |
1860 |
- |
1x630 |
2.4 |
1.77 |
44 |
2400 |
8 |
2x10 |
0.7 |
1.43 |
16,0 |
275 |
6 |
2x16 |
0.7 |
1.43 |
18,5 |
360 |
4 |
2x25 |
0.9 |
1.43 |
22,0 |
530 |
2 |
2x35 |
0.9 |
1.43 |
24,5 |
640 |
8 |
3x10 |
0.7 |
1.43 |
17,0 |
300 |
6 |
3x16 |
0.7 |
1.43 |
19,5 |
400 |
4 |
3x25 |
0.9 |
1.43 |
23,5 |
600 |
2 |
3x35 |
0.9 |
1.43 |
26,0 |
750 |
1 |
3x50 |
1 |
1.43 |
29,0 |
970 |
2/0 |
3x70 |
1.1 |
1.52 |
34,0 |
1310 |
3/0 |
3x95 |
1.1 |
1.6 |
38,5 |
1730 |
4/0 |
3x120 |
1.2 |
1.69 |
42,5 |
2120 |
300MCM |
3x150 |
1.4 |
1.86 |
47,5 |
2640 |
500MCM |
3x185 |
1.6 |
1.94 |
53,0 |
3290 |
750MCM |
3x240 |
1.7 |
2.11 |
59,5 |
4210 |
|
3x300 |
1.8 |
2.28 |
66,0 |
5210 |
4 |
4x25 |
0.9 |
1.43 |
25,5 |
720 |
2 |
4x35 |
0.9 |
1.43 |
28,5 |
910 |
1 |
3x50+35 |
1 |
1.52 |
31,1 |
1130 |
2/0 |
3x70+50 |
1.1 |
1.6 |
36,2 |
1540 |
3/0 |
3x95+50 |
1.1 |
1.69 |
40,6 |
1940 |
4/0 |
3x120+70 |
1.2 |
1.86 |
45,4 |
2430 |
300MCM |
3x150+70 |
1.4 |
1.94 |
49,5 |
2890 |
500MCM |
3x185+70 |
1.6 |
2.11 |
54,4 |
3660 |
750MCM |
3x240+95 |
1.7 |
2.28 |
61,5 |
4680 |
Packing & Shipping:
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
Any needs or question, please contact VIVIAN YUAN , we will be more pleasure to service you.
We are looking forward to your inquiry and nice cooperation.