Cable Comunicacion RS485 1px22AWG Tc 2X2X24AWG Indoor Use RS485 Communication Cable

Product Details
Customization: Available
Application: Local Communication Cable, Coaxial Cable, LAN Cable, Long Distance Symmetric Cable, Submarine Cable
Conductor Material: Copper
Still deciding? Get samples of US$ 5/Meter
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
43
Year of Establishment
2013-12-06
  • Cable Comunicacion RS485 1px22AWG Tc 2X2X24AWG Indoor Use RS485 Communication Cable
  • Cable Comunicacion RS485 1px22AWG Tc 2X2X24AWG Indoor Use RS485 Communication Cable
  • Cable Comunicacion RS485 1px22AWG Tc 2X2X24AWG Indoor Use RS485 Communication Cable
  • Cable Comunicacion RS485 1px22AWG Tc 2X2X24AWG Indoor Use RS485 Communication Cable
  • Cable Comunicacion RS485 1px22AWG Tc 2X2X24AWG Indoor Use RS485 Communication Cable
  • Cable Comunicacion RS485 1px22AWG Tc 2X2X24AWG Indoor Use RS485 Communication Cable
Find Similar Products

Basic Info.

Model NO.
RS 485
Cover Material
PVC
Type
RS-485 Cable
Material Shape
Round Wire
Conductor Type
Stranded
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC
Model
RS-485
Brand
N/a
Standard
En50228-7, IEC60332
Rated Voltage
300/500 V
Individual & Overall
Foil Shield and Drain Wire
Cable RS485
Commonly Rely on 120-Ohm Cables
Transport Package
1000m/Roll
Specification
0.2mm2 to 0.5mm2
Trademark
Hongda
Origin
China
HS Code
8544492100
Production Capacity
800km/Month

Product Description

Cable Comunicacion RS485 1PX22AWG TC 2x2x24AWG Indoor use rs485 communication cable
Constructions
1. Conductor: Stranded Tinned Copper Wire
2. Insulation: S-PE, S-FPE
3. Cabling: Twist Pairs laying-up
4. Screened: Individually Screened (Optional)
    Al-PET tape with Tinned Copper Drain Wire
    Tinned Copper Wire Braided Screen
    Al-PET Tape & Tinned Copper Braided
5. Bedding for Armored Cable (Where Applicable):
    Polyethylene (PE)
    PVC
6. Armor (Where Applicable): Galvanized Steel Wire
7. Over sheath: PVC/LSZH

Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 65ºC
Cable Comunicacion RS485 1px22AWG Tc 2X2X24AWG Indoor Use RS485 Communication CableReference Standards
TIA/EIA-485
BS EN 50288-7
BS EN 60228
BS EN 50290

Identification of Insulation

1st Pair

White, Blue

3rd Pair

White, Green

2nd Pair

White, Yellow

4th Pair

White, Brown

Electrical Performance

Working Voltage

300V

Characteristic Impedance

120 Ω ± 15 Ω

Velocity of Propagation

S-FPE: 78%, SPE: 66%

Conductor DCR

57.0 Ω/km (Max. @ 20°C) for 22AWG

91.80 Ω/km (Max. @ 20°C) for 24AWG

Part No.

Conductor Construction

Insulation

Screen

Sheath

Material

Size

1x2x24AWG

TC

1x2x24AWG

S-PE

Al-foil + Braid

PVC

2x2x24AWG

TC

2x2x24AWG

S-PE

Al-foil + Braid

PVC

3x2x24AWG

TC

3x2x24AWG

S-PE

Al-foil + Braid

PVC

4x2x24AWG

TC

4x2x24AWG

S-PE

Al-foil + Braid

PVC

1x2x24AWG

TC

1x2x24AWG

S-PE

Al-foil + Braid

LSZH

2x2x24AWG

TC

2x2x24AWG

S-PE

Al-foil + Braid

LSZH

3x2x24AWG

TC

3x2x24AWG

S-PE

Al-foil + Braid

LSZH

4x2x24AWG

TC

4x2x24AWG

S-PE

Al-foil + Braid

LSZH

1x2x22AWG

TC

1x2x22AWG

S-FPE

Al-foil + Braid

PVC

2x2x22AWG

TC

2x2x22AWG

S-FPE

Al-foil + Braid

PVC

3x2x22AWG

TC

3x2x22AWG

S-FPE

Al-foil + Braid

PVC

4x2x24AWG

TC

4x2x22AWG

S-FPE

Al-foil + Braid

PVC

(Notes: Other cores are available upon request.)

Applications

RS-485 communication cable

RS-485 communication cable can be twisted pair in general occasions, but twisted pair cable with shielding layer can be used in the environment with high requirements. When RS485 communication is used, for a specific transmission line, the cable length from the host (call test equipment) to the 485 port of the instrument is inversely proportional to the baud rate of data signal transmission; This length is mainly affected by signal distortion and noise. Theoretically, the transmission distance of RS485 can reach 1200 meters, but in practical application, the transmission distance should be less than 1200 meters. The specific length is affected by the surrounding environment.

Construction

24 AWG stranded (7x32) tined copper conductors,polyethylene insulation,twisted par, overall (100%coverage)+ TC braid shied (80%coveroge), 24 AWG stranded Tc drain wire, LSZH jacket.

Cable Comunicacion RS485 1px22AWG Tc 2X2X24AWG Indoor Use RS485 Communication Cable
Cable Comunicacion RS485 1px22AWG Tc 2X2X24AWG Indoor Use RS485 Communication Cable



RS485 fieldbus has a characteristic impedance of 120 ohms. The conductor is stranded by 2 * 2 * 24awg multi strand tinned electrolytic copper wire. The decor insulating sheath is suitable for installation and identification. The aluminum foil / polyester tape is 100% shielded. An independent multi strand tinned copper wire grounding conductor is added. The outer sheath is industrial gray PVC, and the color of the outer sheath is optional.

RS485 fieldbus is applicable to EIA RS-232 / 422 communication network. It is a common cable model for building automation, industrial control network, power automation and other communication networks.

Product Description: the characteristic impedance is 120 ohms, the conductor is stranded by 2 * 2 * 24awg multi strand tinned electrolytic copper wire, the color insulation sheath is suitable for installation and identification, the aluminum foil / polyester tape is 100% shielded, an independent multi strand tinned copper wire grounding conductor is added, and the industrial gray PVC outer sheath is in accordance with UL AWM 2919.

RS-485 communication cable

RS-485 communication cable can be twisted pair in general occasions, but twisted pair cable with shielding layer can be used in the environment with high requirements. When RS485 communication is used, for a specific transmission line, the cable length from the host (call test equipment) to the 485 port of the instrument is inversely proportional to the baud rate of data signal transmission; This length is mainly affected by signal distortion and noise. Theoretically, the transmission distance of RS485 can reach 1200 meters, but in practical application, the transmission distance should be less than 1200 meters. The specific length is affected by the surrounding environment.

RS485 cable price, RS485 communication cable, RS485 twisted pair

Twisted pair shielded cables with impedance of 120 Ω are widely used in RS485 / 422, CANbus and other buses. There are many specifications of this series of cables. Please provide parameters such as cable laying environment, communication rate, relay free transmission distance and so on. We will recommend products according to specific conditions. General recommendations are as follows:

Ordinary twisted pair shielded cable stp-120 Ω (for RS485 & can) one pair 20 AWG, with an outer diameter of about 7.7mm. Suitable for indoor, pipeline and general industrial environment. When in use, one end of the shielding layer is grounded!

Ordinary twisted pair shielded cable stp-120 Ω (for RS485 & can) one pair 18 AWG, with an outer diameter of about 8.2mm. Suitable for indoor, pipeline and general industrial environment. When in use, one end of the shielding layer is grounded!

Armored twisted pair shielded cable astp-120 Ω (for RS485 & can) one pair 18 AWG, with an outer diameter of about 12.3mm. It can be used in places with serious interference, frequent rat damage and lightning protection and explosion-proof requirements. When in use, it is recommended that both ends of the armor layer be grounded and one end of the inner shielding layer be grounded!

Stp-100 Ω (for FF & Profibus-PA) one pair 18 AWG twisted pair shielded cable with sexual impedance of 100 Ω is applied to FF and Profibus-PA buses, and 18awg conductor is commonly used.

Cable Comunicacion RS485 1px22AWG Tc 2X2X24AWG Indoor Use RS485 Communication Cable

Packing & Shipping:

Packing
Steel wooden drum (fumigation)
Cable length in each drum: 1000m/2000m or as per actual cable length requirements.

Drum size:
As per cable length and container size
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!

Shipping Port:
Shanghai, Qingdao, Tianjin or other ports as per your requirements.

Sea freight:
FOB/C&F/CIF/DAP quotation are all available.



*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
 
We are looking forward to your inquiry and nice cooperation.

Cable Comunicacion RS485 1px22AWG Tc 2X2X24AWG Indoor Use RS485 Communication Cable

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier