duplex abc cable
Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
duplex abc cable
service drop cable meets or exceeds the following ASTM specifications:
· B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
· B-231 Aluminum Conductors, Concentric-Lay-Stranded.
· B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
· B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
· B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire
duplex abc cable
Conductors are concentrically stranded, compressed 1350 H-19 aluminum. Insulated with either polyethylene or cross-linked polyethylene (XLPE). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.
Service Drop Cable: Duplex, Triplex and Quadruplex
Voltage: 600V
I. Service Drop Cable Application
Used for lighting, outdoor lighting, & temporary service for construction.
II. Service Drop Cable Operating characteristics
Voltage: 600V phase to phase
Max conductor temperature: 75C (PVC Insulation)
Max conductor temperature: 90C (XLPE Insulation)
III. Service Drop Cable Installation:
For service at 600 volts or less (phase to phase) at a maximum conductor temperature of 75C for Polyethylene insulation or 90C for Cross-Linked (XLPE) insulation
IV. Specifications
B-230 Aluminum Wire, 1350-H19 for electrical purposes
B-231 Aluminum Conductors, concentric-lay-stranded
B-232 Aluminum Conductors, concentric-lay-stranded, coated steel reinforced(ACSR)
B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
B-498 Zinc-coated Steel Core Wire for Aluminum Conductors, steel reinforced(ACSR/AZ)
Service Drop cable meets or exceeds all aplicable requierements ofANSI/ICEA S-76-474.
1.STANDARDS
National : ICEA S-76-474
2.DESCRIPTION
Duplex Overhead Secondary Distribution Cable assemblies consist of one insulated phase conductor and a bare neutral conductor. They are intended for use either as a service drop cable between a power pole and the service entrance, or as a secondary distribution cable between poles. Their use should be limited to circuits not exceeding 600 volts phase-to-phase and a 90°C normal conductor temperature.
3.Phase Conductor Construction
The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.
4.Neutral Conductor Construction
5.Cable assemblies are available with the following neutral conductors:
Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded
Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded
Aluminum alloy 6201-T81, concentric-lay-stranded
6.Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)
Alternatively, black linear low-density polyethylene (LLDPE) insulation with a 75°C temperature rating is available upon request.
7.The XLPE insulation meets the requirements of ANSI/ICEA S-76-474-2004 (Standard for Neutral-Supported Power Cable Assemblies with Weather-Resistant Extruded Insulation Rated 600 Volts).
The LLDPE insulation meets the requirements of ASTM Standard D1248-05 (Standard Specification for Polyethylene Plastics Molding and Extrusion Materials).
Assembly
8.The insulated phase conductor is twisted around the bare neutral conductor with a right-hand lay length of 25 to 60 times the diameter of the phase conductor.
9.Overhead Secondary Distribution Cable is manufactured and tested in accordance with ANSI/ICEA S-76-474-2004 (Standard for Neutral-Supported Power Cable Assemblies with Weather-Resistant Extruded Insulation Rated 600 Volts).
Construction
1.Phase Conductor: Aluminum conductor and compact circular stranded
2.Messenger Conductor: Aluminum alloy conductor and compact circular stranded
3.Insulation: Extruded black weather-resistant Polythylene (PE) or Cross-linked Polythylene(XLPE)
4.Completed cable:Insulated phase conductors shall be held firmly onto the insulated neutral messenger
duplex Service Drop | AAC | Pekingese | 45 | 162 | 252 | 563 | 78 |
Collie | 45 | 183 | 273 | 563 | 78 | ||
Cocker | 60 | 183 | 303 | 563 | 78 | ||
Dachshund | 45 | 204 | 294 | 881 | 103 | ||
Spaniel | 45 | 231 | 321 | 881 | 103 | ||
Cairn | 60 | 231 | 351 | 881 | 103 | ||
Doberman | 45 | 292 | 382 | 1350 | 136 | ||
Airedale | 60 | 332 | 452 | --- | 158 | ||
Basset | 60 | 368 | 488 | 1990 | 182 | ||
Malemure | 60 | 372 | 492 | 1990 | 182 | ||
AAAC | Chihuahua | 45 | 162 | 252 | 1100 | 78 | |
Vizsla | 45 | 183 | 273 | 1100 | 78 | ||
Harrier | 45 | 204 | 294 | 1760 | 103 | ||
Whippet | 45 | 231 | 321 | 1760 | 103 | ||
Schnauzer | 45 | 292 | 382 | 2800 | 136 | ||
Afghan | 60 | 368 | 488 | 4460 | 182 | ||
heeler | 60 | 372 | 492 | 4460 | 182 | ||
ACSR | Setter | 45 | 162 | 252 | 1190 | 78 | |
Shepherd | 45 | 183 | 273 | 1190 | 78 | ||
Retriever | 60 | 183 | 303 | 1190 | 78 | ||
Eskimo | 45 | 204 | 294 | 1860 | 103 | ||
Terrier | 45 | 231 | 321 | 1860 | 103 | ||
Yorkshire | 60 | 231 | 351 | 1860 | 103 | ||
Chow | 45 | 292 | 382 | 2850 | 136 | ||
Labrador | 60 | 332 | 452 | 3550 | 158 | ||
Bloodhound | 60 | 368 | 488 | 4380 | 182 | ||
Bull | 60 | 372 | 492 | 4380 | 182 |
Code Name |
Phase Conductor |
Bare Neutral Messenger |
Weight Per 1000 ft(lbs) |
Rating(Amps) |
||||||
Size AWG |
Strand |
Insulation thickness (mls) |
Size AWG |
Strand |
Breaking strength (lbs) |
XLP |
POLY |
XLP |
POLY |
|
AAC NEUTRAL-MESSNGER |
||||||||||
Clydesdale |
4 |
Solid |
45 |
4 |
7 |
881 |
208 |
201.8 |
100 |
80 |
Pinto |
4 |
7/w |
45 |
4 |
7 |
881 |
223 |
207.9 |
100 |
80 |
Mustang |
2 |
7/w |
45 |
2 |
7 |
1,350 |
333 |
312.6 |
135 |
105 |
Criollo |
1/0 |
19/w |
60 |
1/0 |
7 |
1,990 |
529 |
504.5 |
180 |
140 |
Percheron |
2/0 |
19/w |
60 |
2/0 |
7 |
2,510 |
649 |
620.5 |
205 |
160 |
Hanoverian |
3/0 |
19/w |
60 |
3/0 |
19 |
3,310 |
799 |
765.6 |
235 |
185 |
Oldenburg |
4/0 |
19/w |
60 |
4/0 |
19 |
4,020 |
986 |
946.7 |
275 |
210 |
Lippizaner |
336.4 |
19/w |
80 |
336.4 |
19 |
6,146 |
1,546 |
1,519.2 |
370 |
280 |
ACSR NEUTRAL-MESSNGER |
||||||||||
Morochuca |
6 |
Solid |
45 |
6 |
6/1 |
1,190 |
152 |
147.4 |
75 |
60 |
Chola |
6 |
7/w |
45 |
6 |
6/1 |
1,190 |
162 |
151.7 |
75 |
60 |
Morgan |
4 |
Solid |
45 |
4 |
6/1 |
1,860 |
226 |
220 |
100 |
80 |
Hackney |
4 |
7/w |
45 |
4 |
6/1 |
1,860 |
241 |
226.1 |
100 |
80 |
Palomino |
2 |
7/w |
45 |
2 |
6/1 |
2,850 |
362 |
342.6 |
135 |
105 |
Costena |
1/0 |
19/w |
60 |
1/0 |
6/1 |
4,380 |
575 |
550.6 |
180 |
140 |
Grullo |
2/0 |
19/w |
60 |
2/0 |
6/1 |
5,310 |
707 |
678.7 |
205 |
160 |
Suffolk |
3/0 |
19/w |
60 |
3/0 |
6/1 |
6,620 |
872 |
838.9 |
235 |
185 |
Appaloosa |
4/0 |
19/w |
60 |
4/0 |
6/1 |
8,350 |
1079 |
1039.2 |
275 |
210 |
Bronco |
336.4 |
19/w |
80 |
336.4 |
18/1 |
8,580 |
1613 |
1568.2 |
370 |
280 |
Gelding |
336.4 |
19/w |
80 |
4/0 |
6/1 |
8,350 |
1548 |
1494.3 |
370 |
280 |
|
||||||||||
Code Name |
Phase Conductor |
Bare Neutral Messenger |
Weight Per 1000 ft(lbs) |
Rating(Amps) |
||||||
Size AWG |
Strand |
Insulation thickness (mls) |
Size AWG |
Strand |
Breaking strength (lbs) |
XLP |
POLY |
XLP |
POLY |
|
6201 ALLOY NEUTRAL-MESSENGER |
||||||||||
Bay |
6 |
Solid |
45 |
6 |
7 |
1,110 |
145 |
140.0 |
75 |
60 |
French Coach |
6 |
7/w |
45 |
6 |
7 |
1,110 |
155 |
144.3 |
75 |
60 |
German Coach |
4 |
Solid |
45 |
4 |
7 |
1,760 |
214 |
208.3 |
100 |
80 |
Arabian |
4 |
7/w |
45 |
4 |
7 |
1,760 |
229 |
214.4 |
100 |
80 |
Belgian |
2 |
7/w |
45 |
2 |
7 |
2,800 |
344 |
323.1 |
135 |
105 |
Shetland |
1/0 |
19/w |
60 |
1/0 |
7 |
4,460 |
546 |
521.1 |
180 |
140 |