12/20 18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables

Product Details
Customization: Available
Application: Construction, Overhead, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Quality Assurance
The supplier provides quality assurance
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (20)
  • 12/20 18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables
  • 12/20 18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables
  • 12/20 18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables
  • 12/20 18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables
  • 12/20 18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables
  • 12/20 18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables
Find Similar Products

Basic Info.

Model NO.
Medium Voltage Overhead Covers Conductors
Current
AC Cable
Insulation Material
XLPE
Sheath Material
HDPE
Material Shape
Round Wire
Wire Core Material
AAAC or ACSR
Certification
ISO, CCC, CE
Model
CCT Cables
Brand
OEM
Transport Package
Wooden Drum
Specification
2.5~400sqmm
Trademark
OEM
Origin
China(Mainland)
HS Code
8544492100
Production Capacity
500 Kilometer/Month

Product Description

 

12/20 18/30 kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables
Medium Voltage Overhead Covers Conductors Thick Application

Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables used in power supply in power transmission and distribution line.

Overhead single core cables with aluminum alloy conductor and XLPE insulation, for overhead power transmission and distribution lines up to 20 K & 33 KV. The Covered Conductor Thick (CCT) system, although not a touch-safe screened cable system, is designed to provide protection from initiation of flash-overs due to clashing of conductors, bird or animal incursions, and tree branches or debris which has blown or fallen on to the line , specially in Weather conditions pollution.

ENGINEERING  SPECIFICATIONS

Standard  EN 50397-1
Rated Voltage  12/20 or 18/30 kv
Conductor  stranded aluminum alloy wire(AAAC) or ACSR.
Core  the conductor is  insulated with a layer of extruded XLPE .
Sheath  over the insulated core is applied an outer protecting  layer of extruded HDPE compound.
 Operating temperature  90°c continues normal operation

 

12/20 18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables

Rated voltage 12/20kV, 18/30kV
Conductor aluminium
Insulation XLPE.
Color Black

12/20 18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables

Medium Voltage Overhead Covers Conductors Thick Dimensions

Description of property

Unit of measurement

Amounts/Specifications

 

 

All Aluminum Alloy Conductors (AAAC)

Aluminum conductor steel reinforced (ACSR)

Size

mm2

70

120

185

MINK

HYENA

WOLF

Conductor Construction

N x mm

7x3.75

19x2.95

19x3.50

ST 1x3.66

AL 6x3.66

ST 7x1.93

AL 7x4.39

ST 7x2.59

AL 30x2.59

Cross Section

mm2

77.3

129.9

182.8

73.6

126.4

194.9

Conductor diameter (compacted)

mm

10.69

14.01

16.63

10.21

13.55

16.86

Covering type

-

XLPE / Black HDPE

Tensile Strength

KN

21.67

36.39

51.23

20.59

38.86

65.46

Electrical Resistance at 20ºC

Ohm/km

0.4467

0.2674

0.1900

0.4767

0.2843

0.1920

Rated voltage

kV

20

33

20

33

20

33

20

33

20

33

20

33

Covering Thickness

(two Layers)

Min

mm

5.5

8.0

5.5

8.0

5.5

8.0

5.5

8.0

5.5

8.0

5.5

8.0

 

Max

mm

6.2

9.1

6.2

9.1

6.2

9.1

6.2

9.1

6.2

9.1

6.2

9.1

 

Min at place

mm

4.85

7.10

4.85

7.10

4.85

7.10

4.85

7.10

4.85

7.10

4.85

7.10

HDPE Thickness

Min

mm

1.1

1.6

1.1

1.6

1.1

1.6

1.1

1.6

1.1

1.6

1.1

1.6

 

Max

mm

1.6

2.2

1.6

2.2

1.6

2.2

1.6

2.2

1.6

2.2

1.6

2.2

Overall Diameter

Min

mm

21.6

26.6

24.8

29.8

27.5

32.5

21.1

26.1

24.5

29.5

27.8

32.8

 

Max

mm

23.2

29.0

26.4

32.2

29.1

34.9

22.7

28.5

26.1

31.9

29.4

35.2

Mass per Unit Length

Kg/km

484

672

682

895

867

1100

514

698

758

967

1076

1311

Packing shipping

12/20 18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables12/20 18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables
If you have another question, pls feel free to contact us below

12/20 18/30 Kv Medium Voltage Overhead Covers Conductors Thick (CCT) - Cables

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier