0.6/1kv NFA2X / NFA2X-T Aerial Bundled Conductor Twisted ABC Cable
1. 0.6/1kV, NFA2X-T
1.1 Application
Bundle conductor for overhead distribution network without and with public lighting. (between pole to pole)
1.2 Construction:
Conductor Phase |
Stranded All Aluminium conductor (AAC) |
Neutral/Messenger |
Stranded All Alloy Aluminium Conductor (AAAC) |
Insulation |
Extrude of XLPE, capable for continous operation at maximum cable's temperature. |
1.3 Classification:
Low Voltage Cable Aerial Bundled Conductor, Twisted Cable
Physical Properties |
Cable size |
Insulation Thickness |
Approx Maximum Diameter |
Approx. Net. Weight |
Standard Length |
Phase |
Neutral / Messenger |
Public Lighting |
Phase |
Neutral/Messenger |
Public Lighting |
mm2 |
mm |
mm |
mm |
mm |
mm |
mm |
kg/km |
m |
2x25+25 |
1.4 |
1.4 |
- |
10.0 |
10.0 |
10.0 |
338 |
500 |
2x35+25 |
1.6 |
1.4 |
- |
11.2 |
10.0 |
10.0 |
394 |
500 |
2x50+35 |
1.6 |
1.6 |
- |
12.6 |
11.2 |
11.2 |
526 |
500 |
2x70+50 |
1.8 |
1.6 |
- |
15.4 |
12.6 |
12.6 |
760 |
500 |
2x95+70 |
2.0 |
1.8 |
- |
17.0 |
15.4 |
15.4 |
975 |
500 |
3x25+25 |
1.4 |
1.4 |
- |
10.0 |
10.0 |
10.0 |
452 |
500 |
3x35+25 |
1.6 |
1.4 |
- |
11.2 |
10.0 |
10.0 |
537 |
500 |
3x50+35 |
1.6 |
1.6 |
- |
12.6 |
11.2 |
11.2 |
717 |
500 |
3x70+50 |
1.8 |
1.6 |
- |
15.4 |
12.6 |
12.6 |
1057 |
500 |
3x95+70 |
2.0 |
1.8 |
- |
17.0 |
15.4 |
15.4 |
1360 |
500 |
3x25+25+2x16 |
1.4 |
1.4 |
1.2 |
10.0 |
10.0 |
8.1 |
602 |
500 |
3x35+25+2x16 |
1.6 |
1.4 |
1.2 |
11.2 |
10.0 |
8.1 |
687 |
500 |
3x50+35+2x16 |
1.6 |
1.6 |
1.2 |
12.6 |
11.2 |
8.1 |
867 |
500 |
3x70+50+2x16 |
1.8 |
1.6 |
1.2 |
15.4 |
12.6 |
8.1 |
1207 |
500 |
3x95+70+2x16 |
2.0 |
1.8 |
1.2 |
17.0 |
15.4 |
8.1 |
1510 |
500 |
3x25+25+16 |
1.4 |
1.4 |
1.2 |
10.0 |
10.0 |
8.1 |
527 |
500 |
3x35+25+16 |
1.6 |
1.4 |
1.2 |
11.2 |
10.0 |
8.1 |
612 |
500 |
3x50+35+16 |
1.6 |
1.6 |
1.2 |
12.6 |
11.2 |
8.1 |
792 |
500 |
3x70+50+16 |
1.8 |
1.6 |
1.2 |
15.4 |
12.6 |
8.1 |
1132 |
500 |
3x95+70+16 |
2.0 |
1.8 |
1.2 |
17.0 |
15.4 |
8.1 |
1435 |
500 |
2. NF2X / NFA2X
Aerial Bundled Conductor , Twisted Cable
2.1 Application:
Bundle conductor for overhead distribution network without and with public lighting. (between pole to pole)
2.2 Construction
Conductor |
NF2X : Stranded Copper Conductor
NFA2X : Stranded All Aluminium Conductor (AAC) |
Insulation |
Extrude of XLPE |
2.3 Classification
Low Voltage Cable
Physical Properties |
Electrical Properties |
Cable Size |
Insulation Thickness |
Approx. Twisted Diameter |
Approx. Net. Weight |
Max. Conductor Resistance at 20ºC |
Current Carrying Capacity at 35ºC |
Calculated Breaking Force |
Standard Length |
mm2 |
mm |
mm |
kg/km |
ohm/km |
A |
kg |
m |
NF2X (Copper Conductor) |
2x6 rm |
1.2 |
13.0 |
136 |
3.080 |
54 |
394 |
2000 |
2x10 rm |
1.2 |
14.0 |
211 |
1.830 |
73 |
656 |
2000 |
2x16 rm |
1.2 |
16.0 |
334 |
1.150 |
97 |
1051 |
1000 |
4x6 rm |
1.2 |
15.7 |
258 |
3.080 |
54 |
788 |
1000 |
4x10 rm |
1.2 |
17.0 |
422 |
1.830 |
73 |
1312 |
1000 |
4x16 rm |
1.2 |
19.0 |
664 |
1.150 |
97 |
2102 |
1000 |
4x25 rm |
1.4 |
24.0 |
1008 |
0.727 |
133 |
3284 |
1000 |
NFA2X (All Aluminum Conductor) |
2x10 rm |
1.2 |
14.0 |
94 |
3.080 |
54 |
322 |
2000 |
2x16 rm |
1.2 |
16.0 |
138 |
1.910 |
72 |
515 |
1000 |
4x10 rm |
1.2 |
17.0 |
187 |
3.080 |
54 |
644 |
1000 |
4x16 rm |
1.2 |
19.0 |
272 |
1.910 |
72 |
1030 |
1000 |
4x25 rm |
1.4 |
24.0 |
423 |
1.200 |
102 |
1610 |
1000 |
4x35 rm |
1.6 |
27.0 |
564 |
0.868 |
125 |
2250 |
1000 |
*Further information about rating factor for certain cable arrangement can be found on supplementary technical information.