Customization: | Available |
---|---|
Application: | Construction, Overhead, Underground, Industrial, Power Station, Dry or Wet Use |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of US$ 2/Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Conductor: | 1350 hard aluminum compact class B, blocked at the longitudinal passage of water by means of blocking wires. |
2. Semiconductor display on the conductor: | Thermoset extruded semiconductor compound. |
3. Insulation: | Cross-linked polyethylene retardant to arborescences (XLP-RA), extruded in a true triple extrusion process. level of isolation of 100% or 133%. |
4. Semiconductor screen over insulation: | Thermoset extruded semiconductor compound, with adequate adhesion to the insulation, which makes it easier to remove the screen. |
5. Semiconductor W / B Tape: | Applied helically under the electrostatic shield, avoiding transverse penetration of moisture (They only correspond to the wet wires in case as required). |
6. Metal shield: | Bare copper wires smoothly applied helically. The total section assigned for each gauge meets the above in the standard NRF-024-CFE. |
7. Nonconductive W / B Strap: | Applied helically on the electrostatic screen, avoiding transverse penetration of moisture (They only correspond to the wet wires in case as required). |
8. Exterior cover: | PVC cover red color or high density polyethylene (HDPE) extruded with three red stripes, with excellent properties mechanical and chemical. |
Conductor | Insulation Thickness (Mils) |
Concentric Neutral |
Cond. Dia.(In) |
Ins. Dia. (In) |
Ins. Shield Diameter (In) |
Jacket Dia.(In) |
Cable Weight (Lbs/Kft) |
Min. Bending Radius (In) |
(A) | (B) | (C) | (D) | |||||
15kv 133% Aluminum Single Phase - Full Neutral | ||||||||
2 Solid Al | 220 | 10-#14 | 0.258 | 0.74 | 0.81 | 1.04 | 545 | 9 |
2 Awg Al | 220 | 10-#14 | 0.284 | 0.76 | 0.83 | 1.06 | 564 | 9 |
1 Solid Al | 220 | 13-#14 | 0.289 | 0.78 | 0.85 | 1.09 | 626 | 9 |
1 Awg Al | 220 | 13-#14 | 0.324 | 0.81 | 0.88 | 1.12 | 655 | 9 |
1/0 Solid Al | 220 | 16-#14 | 0.325 | 0.80 | 0.87 | 1.10 | 686 | 9 |
1/0 Awg Al | 220 | 16-#14 | 0.364 | 0.84 | 0.91 | 1.14 | 720 | 10 |
2/0 Awg Al | 220 | 13-#12 | 0.408 | 0.90 | 0.97 | 1.24 | 872 | 10 |
3/0 Awg Al | 220 | 16-#12 | 0.458 | 0.95 | 1.02 | 1.29 | 993 | 11 |
4/0 Awg Al | 220 | 20-#12 | 0.515 | 0.99 | 1.06 | 1.33 | 1133 | 11 |
250 MCM Al | 220 | 16-#10 | 0.561 | 1.06 | 1.15 | 1.46 | 1398 | 12 |
350 MCM Al | 220 | 16-#9 | 0.664 | 1.16 | 1.25 | 1.59 | 1721 | 13 |
15kv 133% Aluminum Three Phase - One-Third Neutral | ||||||||
2 Solid Al | 220 | 6-#14 | 0.258 | 0.75 | 0.82 | 1.06 | 510 | 9 |
2 Awg Al | 220 | 6-#14 | 0.284 | 0.77 | 0.84 | 1.08 | 533 | 9 |
1 Solid Al | 220 | 6-#14 | 0.289 | 0.78 | 0.85 | 1.09 | 544 | 9 |
1 Awg Al | 220 | 6-#14 | 0.324 | 0.81 | 0.88 | 1.12 | 573 | 9 |
1/0 Solid Al | 220 | 6-#14 | 0.325 | 0.82 | 0.89 | 1.12 | 586 | 9 |
1/0 Awg Al | 220 | 6-#14 | 0.364 | 0.85 | 0.92 | 1.16 | 619 | 10 |
2/0 Awg Al | 220 | 7-#14 | 0.408 | 0.90 | 0.97 | 1.21 | 685 | 10 |
3/0 Awg Al | 220 | 9-#14 | 0.458 | 0.95 | 1.02 | 1.26 | 773 | 11 |
4/0 Awg Al | 220 | 11-#14 | 0.515 | 0.99 | 1.06 | 1.30 | 861 | 11 |
250 MCM Al | 220 | 13-#14 | 0.561 | 1.06 | 1.15 | 1.39 | 1000 | 12 |
350 MCM Al | 220 | 18-#14 | 0.664 | 1.16 | 1.25 | 1.49 | 1226 | 12 |
500 MCM Al | 220 | 16-#12 | 0.794 | 1.29 | 1.38 | 1.71 | 1649 | 14 |
750 MCM Al | 220 | 24-#12 | 0.974 | 1.48 | 1.57 | 1.90 | 2192 | 16 |
1000 MCM Al | 220 | 20-#10 | 1.124 | 1.63 | 1.75 | 2.12 | 2802 | 17 |