XLPE-insulated power cable with aluminium concentric conductor and PVC sheath
CONSTRUCTION:
Aluminum phase conductor: Solid conductor (ru), concentrically stranded conductor (rm), SR EN 60228.
Insulation: Polietilena reticulata (XLPE)
Concentric aluminum screen Multiwire (rm)
Sheath: PVC Flame retarda
Min. bending radius at installation : 10 x cable diameter
Application:
The cables are used to make single-phase connections for U0 / U voltages: 0.6 / 1Kv. The cables are mounted on poles and on the front of the clamps.
Specifications:
SPLIT NEUTRAL AND EARTH
SANS 1507-6
CONDUCTOR TYPE: Insulated neutral and bare earth conductors
Available Sheath Colours:
Black
SPECIFICATIONS:
Cable size |
Construction of phase conductor |
Construction of concentric screen |
Radial thickness of insulation |
Radial thickness of sheath |
Mass of aluminum cond |
Nominal outer diameter |
Mass inf |
|
|
|
mm |
mm |
kg/km |
mm |
kg/km |
16/16 |
7x1.7 |
22x0.94 |
1.3 |
1.8 |
43 |
13.5 |
203 |
16/25 |
7x1.7 |
17x1.35 |
1.3 |
1.8 |
43 |
14 |
228 |
25/25 |
7x2.14 |
17x1.35 |
1.3 |
1.8 |
68 |
15 |
266 |
35/35 |
7x2.5 |
15x1.7 |
1.4 |
1.8 |
93 |
16.9 |
345 |
36/6/35 |
7x2.7Al+1x2.7 Ol |
15x1.7 |
1.4 |
1.8 |
109 |
17.2 |
393 |
50/8/35 |
7x3.2Al+1x3.2 Ol |
15x1.7 |
1.4 |
1.8 |
153 |
18.8 |
469 |
50/8/50 |
7x3.2Al+1x3.2 Ol |
20x1.7 |
1.5 |
1.8 |
153 |
19 |
505 |
All calculations must be verified by a qualified electrician under no circumstances can continental cables be held responsible for an accident resulting from the use of this application. These calculations to be used as a guide line only.