  • AC Cable Na2xs (F) 2y RM 12/20 Kv 1X300/25, 1X240/25
  • AC Cable Na2xs (F) 2y RM 12/20 Kv 1X300/25, 1X240/25
  • AC Cable Na2xs (F) 2y RM 12/20 Kv 1X300/25, 1X240/25
  • AC Cable Na2xs (F) 2y RM 12/20 Kv 1X300/25, 1X240/25
  • AC Cable Na2xs (F) 2y RM 12/20 Kv 1X300/25, 1X240/25
Find Similar Products

Basic Info.

Model NO.
cable NA2XS(F)2Y
Current
AC Cable
Insulation Material
XLPE
Sheath Material
PE
Material Shape
Round Wire
Wire Core Material
Copper or Aluminum
Certification
ISO, CCC, CE, RoHS
Model
Na2xs(F)2y
Brand
Hongda
Armour
Steel Wire/Tape Armour/No
Conductor Material
Copper/Aluminum
Standard
IEC 60502-1
Quality Guarantee
Ten Years
Core
1core/Multicore
Sheath Color
Black
Sample
Yes
Manufacture
Yes
Transport Package
Wooden Drum
Specification
single core power cable
Trademark
Hongda
Origin
China, Henan
HS Code
8544601200
Production Capacity
500km/Per Months

Product Description

NA2XS(F)2Y
Medium voltage single core cable 6/10 kV, 12/20 kV, 18/30 kV, XLPE insulated, PE sheathed, with Al conductors and screen of Cu conductors, longitudinally watertight

Application:
Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals, in dry areas or in water. PE sheath secures increased mechanical resistance during and after laying. Swellable tape blocks water spreading within the cable. Due to its very low factor of dielectric loss, which remains constant over its entire operating lifetime, and owing to excellent insulation property of XLPE-material, firmly longitudinally spliced with inner and external screen of semi-conductive material (extruded in one process), the cable has a high operating reliability. Used in transformer stations, switching blocks, in electric power plants and industrial plants. To avoid the effects of external impact, the adhering semi-conductive layer extruded between conductor and insulation, along with concentric copper conductor, secures restriction of electric field and resistance to partial discharges.
 
CHARACTERISTICS:
Temperature Rating -20°C to +70°C
Minimum Bending Radius 15 x overall diameter
Sheath Colour Black
NA2XS(F)2Y Aluminium Conductor XLPE PE-12/20 (24)kV Cable
CONSTRUCTION:
AC Cable Na2xs (F) 2y RM 12/20 Kv 1X300/25, 1X240/25
1. Conductor Aluminum conductor
2. Conductor screen Inner semi-conducting layer
3. Insulation XLPE insulation
4. Insulation screen Outer semi-conducting layer
5. Tape Conductive tape
6. Metallic shield Copper wire screen and copper tape
7. Water blocking Water-blocking tape
8. Outer sheath PE outer sheath

Technical details:
Dimensions - number of cores x conductor cross-section Construction External diameter External diameter Conductor diameter Insulation thickness Conductor resistance at 20 °C Short circuit current 1s Cu weight Cable weight Packing*
    min. max. max. nom. max. nominal   approx.  
N x mm²   mm mm mm mm Ω/km A kg/km kg/km  
6/10 kV
1 x 50/16 RM 24 29 8,6 3,4 0,641 4,7 182 653 CUT
1 x 70/16 RM 26 31 10,2 3,4 0,443 6,58 182 740 CUT
1 x 95/16 RM 27 32 12,0 3,4 0,32 8,93 182 856 CUT
1 x 120/16 RM 29 34 13,5 3,4 0,253 11,3 182 954 CUT
1 x 150/16 RM 30 35 15,0 3,4 0,206 14,1 182 1100 CUT
1 x 150/25 RM 30 35 15,0 3,4 0,206 14,1 283 1132 CUT
1 x 185/16 RM 32 37 16,8 3,4 0,164 17,4 182 1250 CUT
1 x 185/25 RM 32 37 16,8 3,4 0,164 17,4 283 1273 CUT
1 x 240/16 RM 34 39 19,2 3,4 0,125 22,6 182 1400 CUT
1 x 240/25 RM 34 39 19,2 3,4 0,125 22,6 283 1478 CUT
1 x 300/25 RM 36 41 21,6 3,4 0,1 28,2 283 1684 CUT
1 x 400/35 RM 40 45 24,6 3,4 0,0778 37,6 394 2082 CUT
1 x 500/35 RM 43 48 27,6 3,4 0,0605 47 394 2445 CUT
12/20 kV
1 x 50/16 RM 28 33 8,6 5,5 0,641 4,7 182 810 CUT
1 x 70/16 RM 30 35 10,2 5,5 0,443 6,58 182 907 CUT
1 x 95/16 RM 31 36 12,0 5,5 0,32 8,93 182 1034 CUT
1 x 120/16 RM 33 38 13,5 5,5 0,253 11,3 182 1139 CUT
1 x 150/16 RM 34 39 15,0 5,5 0,206 14,1 182 1251 CUT
1 x 150/25 RM 34 39 15,0 5,5 0,206 14,1 283 1324 CUT
1 x 185/16 RM 36 41 16,8 5,5 0,164 17,4 182 1450 CUT
1 x 185/25 RM 36 41 16,8 5,5 0,164 17,4 283 1479 CUT
1 x 240/16 RM 39 44 19,2 5,5 0,125 22,6 182 1693 CUT
1 x 240/25 RM 39 44 19,2 5,5 0,125 22,6 283 1698 CUT
1 x 300/25 RM 41 46 21,6 5,5 0,1 28,2 283 1917 CUT
1 x 400/35 RM 44 49 24,6 5,5 0,0778 37,6 394 2336 CUT
1 x 500/35 RM 47 52 27,6 5,5 0,0605 47 394 2698 CUT
1 x 630/35 RM 51 55 29,3 5,5 0,0469 59,2 394 3166 CUT
18/30 kV
1 x 50/16 RM 33 38 8,6 8,0 0,641 4,7 182 1040 CUT
1 x 70/16 RM 35 40 10,2 8,0 0,443 6,58 182 1151 CUT
1 x 95/16 RM 36 41 12,0 8,0 0,32 8,93 182 1290 CUT
1 x 120/16 RM 38 43 13,5 8,0 0,253 11,3 182 1409 CUT
1 x 150/25 RM 39 44 15,0 8,0 0,206 14,1 283 1603 CUT
1 x 185/25 RM 41 46 16,8 8,0 0,164 17,4 283 1771 CUT
1 x 240/25 RM 43 48 19,2 8,0 0,125 22,6 283 2009 CUT
1 x 300/25 RM 46 51 21,6 8,0 0,1 28,6 283 2704 CUT
1 x 400/35 RM 49 54 24,6 8,0 0,0778 37,6 394 2682 CUT
1 x 500/35 RM 52 57 27,6 8,0 0,0605 47 394 3069  
1 x 630/35 RM 56 62 29,3 8,0 0,0469 59,2 394 3569  
 

*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length

AC Cable Na2xs (F) 2y RM 12/20 Kv 1X300/25, 1X240/25

 

Custom designed medium voltage cables

In addition to standard medium voltage cables, we can design and supply bespoke MV cable products developed for your specific applications. Our custom designed cable solutions provide for variants developed and manufactured around a number of parameters, including:

Cross-sectional area: generally 35mm2 up to 100mm2
Number of cores: generally one or three
Solid or stranded aluminium conductors: for applications requiring a lighter cable weight, also often more economical due to lower aluminium prices. 
Stranded copper conductors: for applications requiring a smaller overall diameter and higher transmitting properties.
Bedding
Bonded or strippable out semi-conducting layer
Water tightness: longitudinal, longitudinal + quasi-radial, longitudinal + radial
Insulation layers (conductor screen, insulation and insulation screen): XLPE, which is more commonly used for MV cables, or EPR which is more flexible and often better suited to marine and offshore applications.
Metallic screen: to nullify the electric field outside the MV cable. Concentric copper wire screens, Aluminium foil laminate, or extruded lead alloy sheath.
Twisted three-core cable or triplex 
Armouring: for mechanical protection. Aluminium wire armoured for single-core cables, Galvanised steel wire armour, strip or tape.
Tapes: Separator tapes to facilitate peeling, water-swellable tapes to prevent water ingress, Conductive tape for core binding.
Outer Sheath: compounds with various properties, tailored to the specific application's requirements, including resistance to oils, greases, rodents, termites, UV and flame, as well as zero halogen emissions.

Medium Voltage cable testing

Some of the tests you would expect from a medium voltage cable manufacturer, and which are performed on our MV cables, include:

Routine tests: These non-destructive tests are normally carried out on all lengths manufactured.
- Conductor resistivity
- Spark test on oversheath
- Voltage tests on sheath
- D.C. voltage test on oversheath

Sample tests: These potentially destructive tests are normally carried out on every production run.
- Examination of conductor and dimensions
- Hot set test for XLPE insulation
- Insulation and oversheath thickness
- Four hour voltage test

Type tests: These destructive tests are normally carried out in addition to the above tests on commencement of a particular cable supply to validate its design.
- Electrical type tests including bending and heat cycle
Non-electrical type tests including mechanical properties after ageing and tests under fire conditions.

Packaging&Delivery.
AC Cable Na2xs (F) 2y RM 12/20 Kv 1X300/25, 1X240/25

Packaging Details:
Wooden drums,steel wooden drums or as your requirement
Delivery Time:Normally within 30 days(detailly depend on the order quantity)

Contact us
Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software.
Vivian Yuan

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier