Power Cables LV Svbt in Electrical Metropolitan Networks and Stations

Product Details
Customization: Available
Application: Construction, Underground, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Quality Assurance
The supplier provides quality assurance
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
to see all verified strength labels (21)
  • Power Cables LV Svbt in Electrical Metropolitan Networks and Stations
  • Power Cables LV Svbt in Electrical Metropolitan Networks and Stations
  • Power Cables LV Svbt in Electrical Metropolitan Networks and Stations
  • Power Cables LV Svbt in Electrical Metropolitan Networks and Stations
  • Power Cables LV Svbt in Electrical Metropolitan Networks and Stations
  • Power Cables LV Svbt in Electrical Metropolitan Networks and Stations
Find Similar Products

Basic Info.

Model NO.
SVBT cable
Current
DC Cable
Insulation Material
PVC
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, SGS
Model
YJV
Brand
Hongda
Rated Voltage
0.6/1kv, 600/1000V, 1.1kv
Transport Package
500m or 1000m Per Drum
Specification
1.5-300 mm2
Trademark
Hongda or OEM
Origin
China
HS Code
8544492100
Production Capacity
4000 Km / Year

Product Description

SVBT
Power cable applicable in electrical metropolitan networks and stations

DESCRIPTION

Used for transfer and distribution of electrical power for switching installation and in static installations, at rated voltage Uo/U to 0,6/1 kV with frequency 50 Hz.These cables are used for indoor installations, in the open air, in ditches, tunnels, canals and shafts.

CONSTRUCTION

Conductor: Cu wire cl.1 or cl.2
Number of cores: 2,5mm2-300mm2  
7-37 cores - 1,5mm- 2,5mm2
Armor:  steel tapes
Insulation:  PVC
Inner sheath: PVC compound
Outher sheath:  PVC
Power Cables LV Svbt in Electrical Metropolitan Networks and Stations

ELECTRICAL CHARACTERISTICS

Temp. characteristic:  
Max operating tº:  +70ºC
Short circuit tº:  +160ºC up to 5 sec.
tº of installation: -5ºC/+50ºC
Ambient tº: -30ºC/+50ºC
Nominal voltage Uo/U: 0,6/1kV
Test voltage: AC 4kV 50Hz DC 12kV
Flame retardant: IEC 60332-1
Min. bending radius: single core: 15xD
 

Color

No. of cores cores without green-yellow
2 brown, blue
3 brown, black, grey
4 blue, brown, black, grey
5 blue, brown, black, grey, black
6 and more black with white numbering
  cores with green-yellow
3 green-yellow, brown, blue
4 green-yellow, brown, black, grey
5 green-yellow, blue, brown, black, grey
6 and more green-yellow, others black with white numbering


Power Cables LV Svbt in Electrical Metropolitan Networks and Stations

Description Number of cores Cross-section /mm2/ Cable weight /kg/km/ Measure unit
SVBT 2 х 1,5 2 1,5 260 m
SVBT 2 х 2,5 2 2,5 260 m
SVBT 2 х 4 2 4 348 m
SVBT 2 х 6 2 6 415 m
SVBT 2 х 10 2 10 538 m
SVBT 2 х 16 2 16 710 m
SVBT 2 х 25 2 25 1038 m
SVBT 2 х 35 2 35 1315 m
SVBT 2 х 50 2 50 1706 m
SVBT 3 х 1,5 3 1,5 252 m
SVBT 3 х 2,5 3 2,5 297 m
SVBT 3 х 4 3 4 410 m
SVBT 3 х 6 3 6 490 m
SVBT 3 х 10 3 10 660 m
SVBT 3 х 16 3 16 880 m
SVBT 3 х 25 3 25 1326 m
SVBT 3 х 35 3 35 1685 m
SVBT 3 х 50 3 50 2210 m
SVBT 3 х 70 3 70 2754 m
SVBT 3 х 95 3 95 3670 m
SVBT 3 х 120 3 120 4452 m
SVBT 3 х 150 3 150 5368 m
SVBT 3 х 185 3 185 6635 m
SVBT 3 х 240 3 240 8501 m
SVBT 3 х 2,5 + 1,5 3 2,5 + 1,5 295 m
SVBT 3 х 4 + 2,5 3 4 + 2,5 450 m
SVBT 3 х 6 + 4 3 6 + 4 545 m
SVBT 3 х 10 + 6 3 10 + 6 736 m
SVBT 3 х 16 + 10 3 16 + 10 996 m
SVBT 3 х 25 + 16 3 25 + 16 1514 m
SVBT 3 х 35 + 16 3 35 + 16 1890 m
SVBT 3 х 50 + 25 3 50 + 25 2499 m
SVBT 3 х 70 + 35 3 70 + 35 3212 m
SVBT 3 х 95 + 50 3 95 + 50 4180 m
SVBT 3 х 120 + 70 3 120 + 70 5260 m
SVBT 3 х 150 + 70 3 150 + 70 6220 m
SVBT 3 х 185 + 95 3 185 + 95 7786 m
SVBT 3 х 240 + 120 3 240 + 120 9910 m
SVBT 4 х 1,5 4 1,5 286 m
SVBT 4 х 2,5 4 2,5 350 m
SVBT 4 х 4 4 4 480 m
SVBT 4 х 6 4 6 580 m
SVBT 4 х 10 4 10 800 m
SVBT 4 х 16 4 16 1080 m
SVBT 4 х 25 4 25 1642 m
SVBT 4 х 35 4 35 2175 m
SVBT 4 х 50 4 50 2767 m
SVBT 4 х 70 4 70 3480 m
SVBT 4 х 95 4 95 4794 m
SVBT 4 х 120 4 120 5805 m
SVBT 4 х 150 4 150 7195 m
SVBT 4 х 185 4 185 8715 m
SVBT 4 х 240 4 240 11090 m
SVBT 5 х 1,5 5 1,5 332 m
SVBT 5 х 2,5 5 2,5 412 m
SVBT 5 х 4 5 4 567 m
SVBT 5 х 6 5 6 706 m
SVBT 5 х 10 5 10 964 m
SVBT 5 х 16 5 16 1324 m
SVBT 5 х 25 5 25 2050 m
SVBT 5 х 35 5 35 2760 m
SVBT 5 х 50 5 50 3840 m
SVBT 5 х 70 5 70 5130 m
SVBT 7 х 1,5 7 1,5 422 m
SVBT 8 х 1,5 8 1,5 465 m
SVBT 10 х 1,5 10 1,5 570 m
SVBT 12 х 1,5 12 1,5 612 m
SVBT 14 х 1,5 14 1,5 677 m
SVBT 16 х 1,5 16 1,5 740 m
SVBT 19 х 1,5 19 1,5 818 m
SVBT 24 х 1,5 24 1,5 1043 m
SVBT 27 х 1,5 27 1,5 1072 m
SVBT 30 х 1,5 30 1,5 1183 m
SVBT 37 х 1,5 37 1,5 1371 m
SVBT 7 х 2,5 7 2,5 509 m
SVBT 8 х 2,5 8 2,5 570 m
SVBT 10 х 2,5 10 2,5 719 m
SVBT 12 х 2,5 12 2,5 779 m
SVBT 14 х 2,5 14 2,5 838 m
SVBT 16 х 2,5 16 2,5 942 m
SVBT 19 х 2,5 19 2,5 1059 m
SVBT 24 х 2,5 24 2,5 1356 m
SVBT 30 х 2,5 30 2,5 1552 m
SVBT 37 х 2,5 37 2,5 1827 m

*Further information about rating factor for certain cable arrangement can be found on supplementary technical information.

STANDARD PACKING
1.5 - 50 sqmm supplied in wooden drum @ 1000 m
70 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Power Cables LV Svbt in Electrical Metropolitan Networks and Stations

More information and other cable inquiry, pls contact Vivian Yuan as follows:

Vivian Yuan

Power Cables LV Svbt in Electrical Metropolitan Networks and Stations

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier