LV Low Voltage XLPE PVC Insulated 4 Core 95mm2 120mm2 240mm2 Aluminum Cable

Application: Construction, Underground, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Current: AC Cable
Insulation Material: XLPE
Sheath Material: PE
Material Shape: Round Wire
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
Aluminum Cable
Wire Core Material
Red Copper Wire
Certification
ISO, CCC
Model
Cu XLPE PE
Brand
OEM
Conductor
Aluminum
Insulation
XLPE
Jacket
PVC
Cores
Multi Core
Transport Package
Wooden Drum
Specification
4 Core 95mm2 120mm2 240mm2
Trademark
OEM
Origin
China(Mainland)
HS Code
8544492100
Production Capacity
50 Kilometer/Month

Product Description

1.Brief Introduction :

       AL/XLPE/PVC cable is  AL conductor XLPE  insulated  PVC sheath Electric power cable for laying buildings,inducts, kin tunnels,direct in ground and underwater,.

For laying indoors, in tunnels, in ducts. Able to bear external mechanical force but not large pulling forces. Single-core cables are impermissible to be laid in magnetic ducts.

 2.Operating characteristics:

Rated power-frequency voltage u0/u:0.6/1 KV

Max permissible continuous operating temperature of conductor 90

Max short-circuit temperature of the conductor shall not exceed (Max 5 seconds duration): cross-section of conductor 300 mm2

      The anbient temperature under installations should not be below 0

      The bending radius of single core cable should not be less than 20 times of the cable diameter ,the bending radius of multi-core cable should not be less than 15 times of the cable diameter

LV Low Voltage XLPE PVC Insulated 4 Core 95mm2 120mm2 240mm2 Aluminum Cable
0.6/1kV-1 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20ºC) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (Ω/km) In Air(A) In Ground(A)
1X10 0.7 1.4 8.0 75 3.08 55 71
1X16 0.7 1.4 9.0 106 1.91 71 91
1X25 0.9 1.4 10.6 150 1.20 94 115
1X35 0.9 1.4 11.6 180 0.868 115 140
1X50 1.0 1.4 13.1 240 0.641 140 165
1X70 1.1 1.4 15.0 320 0.443 180 205
1X95 1.1 1.5 16.8 400 0.320 220 245
1X120 1.2 1.5 18.4 500 0.253 260 280
1X150 1.4 1.6 20.5 600 0.206 300 315
1X185 1.6 1.6 22.6 730 0.164 350 360
1X240 1.7 1.7 25.2 930 0.125 414 420
1x300 1.8 1.8 27.8 1140 0.100 485 475
1x400 2.0 1.9 31.4 1500 0.0778 570 545
1x500 2.2 2.0 34.9 1800 0.0605 670 620
1X630 2.4 2.2 39.1 2285 0.0469 790 705
0.6/1kV-2 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20ºC) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (Ω/km) In Air(A) In Ground(A)
2X10 0.7 1.8 15.4 200 3.08 58 78
2X16 0.7 1.8 17.4 270 1.91 75 100
2X25 0.9 1.8 20.5 380 1.20 100 130
2X35 0.9 1.8 22.5 480 0.868 120 155
2X50 1.0 1.8 20.3 490 0.641 150 185
2X70 1.1 1.8 23.3 630 0.443 190 225
2X95 1.1 1.9 26.2 820 0.320 235 275
2X120 1.2 2.0 29.4 1000 0.253 275 315
2X150 1.4 2.2 32.6 1250 0.206 315 350
2X185 1.6 2.3 36.0 1540 0.164 365 395
0.6/1kV-3 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20ºC) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (/km) In Air(A) In Ground(A)
3X10 0.7 1.8 17.2 250 3.08 50 66
3X16 0.7 1.8 19.4 330 1.91 65 85
3X25 0.9 1.8 22.8 480 1.20 87 110
3X35 0.9 1.8 25.0 580 0.868 105 130
3X50 1.0 1.8 24.4 670 0.641 130 160
3X70 1.1 1.9 29.4 910 0.443 165 195
3X95 1.1 2.0 33.6 1170 0.320 205 235
3X120 1.2 2.1 35.9 1460 0.253 240 265
3X150 1.4 2.3 39.9 1820 0.206 270 300
3X185 1.6 2.4 44.1 2200 0.164 315 340
3X240 1.7 2.6 51.1 2850 0.125 375 395
3X300 1.8 2.7 56.1 3500 0.100 435 445
3X400 2.0 3.0 62.4 4500 0.0778 510 510
0.6/1kV-4 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20ºC) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (Ω/km) In Air(A) In Ground(A)
4X10 0.7 1.8 18.6 300 3.08 50 66
4X16 0.7 1.8 21.0 400 1.91 65 85
4X25 0.9 1.8 24.9 570 1.20 87 110
4X35 0.9 1.8 28.3 710 0.868 105 130
4X50 1.0 1.8 28.4 850 0.641 130 160
4X70 1.1 2.0 33.1 1160 0.443 165 195
4X95 1.1 2.1 37.1 1520 0.320 205 235
4X120 1.2 2.2 40.8 1898 0.253 240 265
4X150 1.4 2.4 45.2 2369 0.206 270 300
4X185 1.6 2.6 52.1 2925 0.164 315 340
4X240 1.7 2.8 57.8 3700 0.125 375 395
4X300 1.8 3.0 63.5 4580 0.100 435 445
4X400 2.0 3.3 70.9 5800 0.0778 510 510
0.6/1kV-5 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20ºC) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (Ω/km) In Air(A) In Ground(A)
5X10 0.7 1.8 18.8 360 3.08 50 66
5X16 0.7 1.8 21.8 485 1.91 65 85
5X25 0.9 1.8 26.2 690 1.20 87 110
5X35 0.9 1.8 28.0 865 0.868 105 130
5X50 1.0 1.9 32.4 1138 0.641 130 160
5X70 1.1 2.1 37.4 1575 0.443 165 195
5X95 1.1 2.2 41.7 2068 0.320 205 235
5X120 1.2 2.4 46.2 2550 0.253 240 265
5X150 1.4 2.6 53.1 3165 0.206 270 300
5X185 1.6 2.8 58.9 3950 0.164 315 340
5X240 1.7 3.0 65.6 5025 0.125 375 395
5X300 1.8 3.2 72.0 6190 0.100 435 445
0.6/1kV-3+1 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20ºC) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (Ω/km) In Air(A) In Ground(A)
3X16+1X10 0.7/0.7 1.8 19.4 370 1.91/3.08 65 85
3X25+1X16 0.9/0.7 1.8 22.8 520 1.20/1.91 87 110
3X35+1X16 0.9/0.7 1.8 25.1 650 0.868/1.91 105 130
3X50+1X25 1.0/0.9 1.8 28.2 780 0.641/1.20 130 160
3X70+1X35 1.1/0.9 1.9 31.9 1050 0.443/0.868 165 195
3X95+1X50 1.1/1.0 2.1 35.7 1460 0.320/0.641 205 235
3X120+1X70 1.2/1.1 2.2 39.6 1820 0.253/0.443 240 265
3X150+1X70 1.4/1.1 2.3 43.6 2150 0.206/0.443 270 300
3X185+1X95 1.6/1.1 2.5 49.8 2725 0.164/0.320 315 340
3X240+1X120 1.7/1.2 2.7 55.3 3480 0.125/0.253 375 395
3X300+1X150 1.8/1.4 2.9 57.0 4230 0.100/0.206 435 445
3X400+1X185 2.0/1.7 3.1 70.0 5520 0.0778/0.164 510 510
0.6/1kV-4+1 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20ºC) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (Ω/km) In Air(A) In Ground(A)
4X16+1X10 0.7/0.7 1.8 21.3 450 1.91/3.08 65 85
4X25+1X16 0.9/0.7 1.8 25.7 650 1.20/1.91 87 110
4X35+1X16 0.9/0.7 1.8 28.2 795 0.868/1.91 105 130
4X50+1X25 1.0/0.9 1.9 28.9 1020 0.641/1.20 130 160
4X70+1X35 1.1/0.9 2.0 32.2 1360 0.443/0.868 165 195
4X95+1X50 1.1/1.0 2.2 36.9 1870 0.320/0.641 205 235
4X120+1X70 1.2/1.1 2.3 40.8 2342 0.253/0.443 240 265
4X150+1X70 1.4/1.1 2.5 44.7 2778 0.206/0.443 270 300
4X185+1X95 1.6/1.1 2.7 50.7 3495 0.164/0.320 315 340
4X240+1X120 1.7/1.2 2.9 56.4 4416 0.125/0.253 375 395
4X300+1X150 1.8/1.4 3.1 64.0 5422 0.100/0.206 435 445
0.6/1kV-3+2 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20ºC) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (Ω/km) In Air(A) In Ground(A)
3X16+2X10 0.7/0.7 1.8 20.8 425 1.91/3.08 65 85
3X25+2X16 0.9/0.7 1.8 25.2 600 1.20/1.91 87 110
3X35+2X16 0.9/0.7 1.8 26.8 720 0.868/1.91 105 130
3X50+2X25 1.0/0.9 1.9 28.7 955 0.641/1.20 130 160
3X70+2X35 1.1/0.9 2.0 33.7 1230 0.443/0.868 165 195
3X95+2X50 1.1/1.0 2.2 38.3 1706 0.320/0.641 205 235
3X120+2X70 1.2/1.1 2.3 43.2 2180 0.253/0.443 240 265
3X150+2X70 1.4/1.1 2.4 46.5 2525 0.206/0.443 270 300
3X185+2X95 1.6/1.1 2.6 51.9 3195 0.164/0.320 315 340
3X240+2X120 1.7/1.2 2.8 58.0 4050 0.125/0.253 375 395
3X300+2X150 1.8/1.4 3.0 64.2 4983 0.100/0.206 435 445


Packing shipping
LV Low Voltage XLPE PVC Insulated 4 Core 95mm2 120mm2 240mm2 Aluminum Cable
 LV Low Voltage XLPE PVC Insulated 4 Core 95mm2 120mm2 240mm2 Aluminum Cable 
LV Low Voltage XLPE PVC Insulated 4 Core 95mm2 120mm2 240mm2 Aluminum Cable
Why Choose Us ?
1. We have a large production base, and advanced production equipment 
2. Have an competitive price and high quality
3. Excellent after-sale service
4. Free issue:packaging list,invoice
5. Powerful technology team
6. Strict quality assurance system and perfect testing means
7. Advanced process equipment
8. Delivery on time
9. Our cable sales to Middle East,Africa,Russia,Southeast Asia, etc.
10.We have a good reputation in the overseas
LV Low Voltage XLPE PVC Insulated 4 Core 95mm2 120mm2 240mm2 Aluminum Cable

Any problem and inquiry pls contact with Tina
LV Low Voltage XLPE PVC Insulated 4 Core 95mm2 120mm2 240mm2 Aluminum Cable

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
43
Year of Establishment
2013-12-06