• SIP Aluminum Overhead Cable 4*10 4*16
  • SIP Aluminum Overhead Cable 4*10 4*16
  • SIP Aluminum Overhead Cable 4*10 4*16
  • SIP Aluminum Overhead Cable 4*10 4*16
  • SIP Aluminum Overhead Cable 4*10 4*16
  • SIP Aluminum Overhead Cable 4*10 4*16

SIP Aluminum Overhead Cable 4*10 4*16

Application: Overhead
Voltage: Low and Medium Voltage Cable
Current: DC Cable
Insulation Material: XLPE
Sheath Material: No Jacket
Material Shape: Round Wire
Samples:
US$ 100/Meter 1 Meter(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
SIP
Wire Core Material
Aluminum
Certification
ISO, CCC
Model
ABC
Brand
Hongda
Cores
2 3 4 5
Transport Package
on The Drum or on The Pallent
Specification
10 16 25 35 50 70 95 120
Trademark
hongda
Origin
Henan
HS Code
8544492100
Production Capacity
10000m/Day

Product Description





Self supporting insulated wires (Aerial Bundled Conductor) SIP per GOST R 52373-2005 and TU 16-705.500-2006
(TU 16-705.500-2006 used instead of TU 16.К71-268-98 and TU 16.К71- 272-98)


SIP-1 - self supporting wire with Al cores, with insulation from light-stabilized cross-linked PE,
neutral messenger non-insulated core from Al alloy.
SIP-2 - the same.

SIP-3 - protected self supporting wire, with conducting core from Al alloy with insulation from lightstabilized cross-linked PE.
SIP-4 - protected self supporting wire, without currier element, with Al conducting cores with insulation from light-stabilized cross-linked PE.


CONSTRUCTION
1. CONDUCTING CORE - Al round core  for all cross-section the core is compacted multiwire, the quantity of wire in phase core. Outer diameter of conducting core and its electrical resistance shown in bellow table:
Nominal cross-section of phase core, mm2 Number of wires in the core, units. Outer diameter of conducting core, mm Electrical resistance of 1 km of phase core to DC, ohm not more
Min. Max.
 16  7  4,6  5,1  1,910
 25  7  5,7  6,1  1200
 35  7  6,7  7,1  0,868
 50  7  7,85  8,35  0,641
 70  7  9,45  9,95  0,443
 95  7  11,1  11,7  0,320
 120  19  11,1  13,1  0,253
 150  19  14,0  14,5  0,206
 185  19  15,45  16,15  0,164
 240  19  17,75  18,45  0,125

 
2. NEUTRAL MESSENGING CORE - form Al alloy, round core, stranded from round wires,
compacted. Nominal cross-sections, number of wires in the core, outer diameter of core, its burst capacity and electrical resistance are specified in the bellow table:
Nominal cross-section of phase core, mm2 Number of wires in the core, units. Outer diameter of conducting core, mm Electrical resistance of 1 km of phase core to DC, ohm not more
Min. Max.
 25  7  5,7  6,1  1,380
 35  7  6,7  7,1  0,986
 50  7  7,85  8,35  0,720
 54,6  7  9,2  9,6  0,630
 70  7  9,45  9,95  0,493
 95  7  11,1  11,7  0,363
 120  19  12,2  12,9  0,288
 150  19  13,9  14,5  0,236
 185  19  15,75  16,15  0,188
 240  19  17,75  18,45  0,145
 
3. INSULATION - in SIP-1 the neutral core is not insulated. In other conductors the insulation made from light-stabilized cross-linked PE. Insulated phase cores have the distinctive coloring. Insulation thickness is shown in the following table:
Types of wire
 
Nominal isulation thickness, mm
16 25 35 50 54,6 70 95 120 150 185 240
SIP-1 1,3 1,3 1,3 1,5 1,5 1,7 1,7 1,7 1,7 1,9 1,9
SIP-2
SIP-3 20 kV 2,3
SIP-3 35 kV 3,5
SIP-4 1,3 1,3  
 
APPLICATION
SIP-1 - for overhead transmission lines (TL) and linear TL deviations in atmosphere types I and II as per GOST 15150-69
SIP-2 - for overhead transmission lines (TL) and linear TL deviations in atmosphere types I and II as per GOST 15150-69 , including sea coasts, salt lakes shores, in industrial areas

SIP-3 - for TL with nominal voltage 10-35 kV in atmosphere types II and III as per GOST 15150-69 , including sea coasts, salt lakes shores, in industrial areas
SIP-4 - for TL deviations to entry and for laying in walls of buildings and engineering structures in
atmosphere types II and III as per GOST 15150-69

 
Mark and rated voltage wire Number and nominal cross-phase and zero bearing veins sht.h mm2 Estimate the outer diameter of wire, mm Estimated weight of 1 km of wire, kg
SIP-1 0,6 / 1 kV 1х16+1х25 15 135
3х16+1х25 22 270
3х25+1х35 26 390
3х35+1х50 30 530
3х50+1х50 32 685
3х50+1х70 35 740
3х70+1х70 37 930
3х70+1х95 41 990
3х95+1х70 41 1190
3х95+1х95 43 1255
3х120+1х95 46 1480
3х150+1х95 48 1715
3х185+1х95 52 2330
3х240+1х95 56 2895
SIP-2 0,6 / 1 kV 3х16+1х25 24 308
3х16+1х54,6* 28 427
3х25+1х35 27 424
3х25+1х54,6* 30 512
3х35+1х50 31 571
3х35+1х54,6* 32 606
3х50+1х50 34 727
3х50+1х54,5* 35 762
3х50+1х70 36 798
3х70+1х54,6* 39 973
3х70+1х70 40 1010
3х70+1х95 41 1087
3х95+1х70 43 1240
3х95+1х95 45 1319
3х120+1х95 48 1553
3х150х1х95 50 1787
3х185+1х95 55 2403
3х240+1х95 60 2968
SIP-3 20 кV 1х35 12 165
1х50 13 215
1х70 15 282
1х95 16 364
1х120 18 445
1х150 19 540
1х185 24 722
1х240 24 950
SIP-3 20 кV 1х35 14 209
1х50 16 263
1х70 17 334
1х95 19 421
1х120 20 518
1х150 22 618
1х185 24 808
1х240 26 1045
SIP-4 0,6/1 кV 2х16 15 139
4х16 18 278
2х25 17 196
4х25 21 392