• Copper Concentric German Standard Industrial PVC Cables Nycwy
  • Copper Concentric German Standard Industrial PVC Cables Nycwy
  • Copper Concentric German Standard Industrial PVC Cables Nycwy

Copper Concentric German Standard Industrial PVC Cables Nycwy

Application: Construction, Overhead, Underground, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Current: DC & AC
Insulation Material: PVC
Sheath Material: PVC
Material Shape: Round Wire
Samples:
US$ 3/Meter 1 Meter(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
Industrial Cables NYCWY
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC
Model
Nycwy
Brand
Hongda
Voltage Rating
600/1000V
Transport Package
Steel & Wooden Drum or Customer Requirement
Specification
8AWG to 500MCM
Trademark
Hongda, accept OEM
Origin
China
HS Code
8544492100
Production Capacity
10km/Days

Product Description

Copper Concentric German Standard Industrial PVC Cables NYCWY
NYCWY CABLE

Supplying you with customized nycwy, it is one of the reliable nycwy manufacturers and suppliers, welcome to wholesale our products at good price from our factory.

APPLICATIONS OVERVIEW
The NYCWY cable range is used as fixed wiring power supply for indoor and outdoor applications with a voltage rating of 600/1000V where increased electrical conductivity with accompanying protection is required. It is particularly suited for underground laying, notably in subscriber networks and power stations where it can be buried without additional protection or in concrete. It is also used as control cable for the transmission of control impulses and test data. This range has a water and UV-resistant sheath for outdoor use.

NYCWY-RE / NYCWY-RM / NYCWY-SM CABLE
CONSTRUCTION

Copper Concentric German Standard Industrial PVC Cables Nycwy
Conductor
- NYCWY-RE cable
- NYCWY-RM cable
- NYCWY-SM cable
 
10-16 mm² round, solid conductors (re) alt.
10-25 mm², stranded conductor (rm),
35-240 mm², sector shaped conductor, stranded (sm)
Insulation Polyvinyl Chloride (PVC) DIV4
Bedding PVC
Concentric conductor Waveconal outer conductor (copper wire and counter spiral copper tape)
Sheath PVC
Technical Characteristics - Working voltage: 600/1000 volts
- Test voltage: 4000 volts
- Flexing bending radius: 15 x Ø
- Static bending radius: 12 x Ø
- Flexing temperature: -5º C to +50º C
- Fixed installation temperature: - 40º C to +70º C
- Short circuit temperature: +160º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 100 MΩ x km
This multi-core cable has an operating temperature range of -5oC to +70oC.

NYCWY CABLE DIMENSIONS:

AWG

NO. OF CORES X

NOMINAL CROSS

SECTIONAL AREA

# X MM²

STRANDED CONDUCTOR TYPE

NOMINAL

OVERALL DIAMETER
MM

NOMINAL COPPER WEIGHT KG/KM

NOMINAL CABLE WEIGHT KG/KM

8

2 x 10.0

re / 10.0

19

312

650

6

2 x 16.0

re / 16.0

21.5

489

850

4

2 x 25.0

rm / 25.0

24.5

763

1210

8

3 x 10.0

re / 10.0

19.5

408

730

6

3 x 16.0

re / 16.0

22

643

1000

4

3 x 25.0

rm / 16.0

26

902

1550

4

3 x 25.0

rm / 25.0

26

1003

1600

2

3 x 35.0

sm / 35.0

27.5

1402

1850

2

3 x 35.0

sm / 16.0

27

1190

1750

1

3 x 50.0

sm / 50.0

29.5

2000

2450

1

3 x 50.0

sm / 25.0

29

1723

2250

2/0

3 x 70.0

sm / 70.0

34

2796

3350

2/0

3 x 70.0

sm / 35.0

33

2410

2950

3/0

3 x 95.0

sm / 95.0

38.5

3791

4550

3/0

3 x 95.0

sm / 50.0

38

3296

4100

4/0

3 x 120.0

sm / 70.0

41

4236

5050

4/0

3 x 120.0

sm / 120.0

42

4786

5550

300mcm

3 x 150.0

sm / 70.0

45

5100

6000

300mcm

3 x 150.0

sm / 150.0

46

5970

6900

350mcm

3 x 185.0

sm / 95.0

50

6383

7550

350mcm

3 x 185.0

sm / 185.0

51

7363

8500

500mcm

3 x 240.0

sm / 120.0

57

8242

9950

8

4 x 10.0

re / 10.0

20.5

504

890

6

4 x 16.0

re / 16.0

23.5

796

1250

4

4 x 25.0

rm / 16.0

28

1142

1800

2

4 x 35.0

sm / 16.0

29

1526

2050

1

4 x 50.0

sm / 25.0

33

2203

2700

2/0

4 x 70.0

sm / 35.0

37

3082

3750

3/0

4 x 95.0

sm / 50.0

43.5

4208

5000

4/0

4 x 120.0

sm / 70.0

47

5388

6350

300mcm

4 x 150.0

sm / 70.0

51

6540

7650

350mcm

4 x 185.0

sm / 95.0

56

8159

9350

500mcm

4 x 240.0

sm / 120.0

62.5

10546

11600


For full technical specifications and other core sizes and cross-sectional area sizes please refer to the datasheets or speak to our technical team for more advice.

NYCWY CABLE SELECTION
Our technical team has vast experience advising on European fixed wiring power supply cables, Please contact us for technical support with NYCWY-RE, NYCWY-RM and NYCWY-SM cable selection, or for information about any other cables forming part of this range, including NYY, NYCY, and N2XY cable.

Other standard and specification can be produce depending on customer require.

Copper Concentric German Standard Industrial PVC Cables Nycwy

Copper Concentric German Standard Industrial PVC Cables Nycwy

PACKAGE AND SHIPPING:
Steel wooden drum (fumigation)
Cable length in each drum: 200m/300m or as per actual cable length requirements.
Drum size: As per cable length and container size

Shipping:
Port: Tianjin, Qingdao, or other ports as per your requireents.

Sea freight:
FOB/C&F/CIF/DAP quotation are all available.

Copper Concentric German Standard Industrial PVC Cables Nycwy

*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
Any needs or question, please contact me Mobile:+86-15838290725, we will be more pleasure to service you.
We are looking forward to your inquiry and nice cooperation.
Copper Concentric German Standard Industrial PVC Cables Nycwy

Send your message to this supplier