No Sheath 225kv 2 Line Transmission Line Overhead Aluminum Conductors

Product Details
Customization: Available
Application: Construction, Overhead, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Still deciding? Get samples of US$ 0/Meter
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
43
Year of Establishment
2013-12-06
  • No Sheath 225kv 2 Line Transmission Line Overhead Aluminum Conductors
  • No Sheath 225kv 2 Line Transmission Line Overhead Aluminum Conductors
  • No Sheath 225kv 2 Line Transmission Line Overhead Aluminum Conductors
  • No Sheath 225kv 2 Line Transmission Line Overhead Aluminum Conductors
  • No Sheath 225kv 2 Line Transmission Line Overhead Aluminum Conductors
  • No Sheath 225kv 2 Line Transmission Line Overhead Aluminum Conductors
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
overhead aluminum conductors
Current
DC & AC
Insulation Material
Bare
Sheath Material
No
Material Shape
Round Wire
Wire Core Material
Aluminium / AAC
Certification
ISO, CCC
Model
AAC Conductor
Brand
Hongda
Material
All Aluminum
Transport Package
Drum or as Customer Require
Specification
6AWG to 3500MCM
Trademark
Hongda
Origin
China
HS Code
76149000
Production Capacity
150km/Day

Product Description

Product Description

 

no sheath 225kv 2 line Transmission line overhead aluminum conductors
No Sheath 225kv 2 Line Transmission Line Overhead Aluminum Conductors



AAC All Aluminum Conductor cable gives solid performance in overhead transmission and distribution applications. AAC conductors are utilized as a part of line designs that don't require the strength of ACSR type conductors, while still expanding current conveying limit.

Concentric lay stranded Aluminum Conductors are created from one or more strands of hard drawn 1350-H19 aluminum wires. AAC All Aluminum Conductors are frequently used as low, medium and high voltage overhead lines. AAC has a decent erosion resistance because it is made ONLY from aluminum wires.  It has high value due to the low price, minimum conductivity of 61.2%, IACS low breaking quality and high creep values. AAC has the most noteworthy conductivity per weight among all uncovered overhead conductors.

AAC has seen broad use in urban zones where runs are generally short yet high conductivity is required. The runs need to be short to use AAC because it lacks the reinforcement strands that are built into other cables like the ACSR.  The brilliant erosion resistance of aluminum has made AAC a conductor of choice in all waterfront regions. Due to its generally poor strength to weight proportion, AAC had limited use in transmission lines and rural distribution because of the long spans that are typical in these situations.

Product Highlights:
> Concentrically stranded conductor consisting of aluminum alloy 1350-H19 wires
> Available in both single and multi-layer constructions
> Conductor temperature of 75 C, ambient temperature 25 C, emissivity 0.5
> Wind 2 feet per second in the sun.
> high Current Carrying Capacity
> incredible resistance to corrosion
> perfect for use in waterfront territory
> suitable for low and medium voltage lines in urban territory

Technical Standards:
B-230 aluminum 1350-H19, extra hard, round wire for electrical purposes. The aluminum wire shall be made from drawing stock and shall be free of brittleness as evidenced by its ability to be coiled or looped around its own diameter with or without a mandrel.
B-231 aluminum 1350-H19, 1350-H16 or -H26, 1350-H14 or -H24, and 1350-H142 or -H242, bare concentric-lay-stranded conductors constructed with a straight round central wire surrounded by one or more layers of helically layered wires.
B-400 aluminum1350-H19, 1350-H16 or -H26, 1350-H14 or -H24, and 1350-H142 or -H242 bare compact-round concentric-lay-stranded conductors made from round or shaped wires for use as uninsulated electric conductors or in covered or insulated electrical conductors.
 
Product Parameters

 

Specification:        
Code Word Size (AWG
or kcmil)
Stranding Diameter Cross-Sectional Area (Sq. ins.) Weight Per
1000 ft. (lbs.)
Rated
Strength (lbs.)
Allowable
Ampacity
No. of
Wires
Class. Individual Wires Complete Cable
Peachbell 6 7 A .0612 .184 .0206 25 563 103
Rose 4 7 A .0772 .232 .0328 39 881 138
Iris 2 7 AA, A .0974 .292 .0522 62 1350 185
Pansy 1 7 AA .1093 .328 .0657 78 1640 214
Poppy 1/0 7 AA, A .1228 .368 .0829 99 1990 247
Aster 2/0 7 AA, A .1379 .414 .1045 125 2510 286
Phlox 3/0 7 AA, A .1548 .464 .1317 157 3040 331
Oxlip 4/0 7 AA, A .1739 .522 .1663 198 3830 383
Sneezewort 250 7 AA .189 .567 .1964 234 4520 425
Valerian 250 19 A .1147 .574 .1963 234 4660 426
Daisy 266.8 7 AA .1952 .586 .2095 250 4830 443
Laurel 266.8 19 A .1185 .592 .2095 250 4970 444
Peony 300 19 A .1257 .628 .2358 281 5480 478
Tulip 336.4 19 A .1331 .665 .2644 315 6150 513
Daffodil 350 19 A .1357 .679 .2748 328 6390 526
Canna 397.5 19 AA, A .1446 .723 .312 373 7110 570
Goldentuft 450 19 AA .1539 .769 .3534 422 7890 616
Cosmos 477 19 AA .1584 .792 .3744 447 8690 639
Syringa 477 37 A .1135 .795 .3744 447 8690 639
Zinna 500 19 AA .1162 .811 .3926 469 8760 658
Hyacinth 500 37 AA .1162 .814 .3924 469 9110 658
Dahlia 556.5 19 AA .1711 .856 .4369 522 9750 703
Mistletoe 556.5 37 AA .1226 .858 .4368 522 9940 704
Meadowsweet 600 37 AA .1273 .891 .4709 562 10700 738
Orchid 636.0 37 AA, A .1311 .918 .4995 596 11400 765
Heuchera 650 37 AA .1325 .928 .5102 609 11600 775
Verbena 700 37 AA .1375 .963 .5494 656 12500 812
Flag 700 61 A .1071 .964 .5495 656 12900 812
Violet 715.5 37 AA .1391 .973 .5623 671 12800 823
Nasturtium 715.5 61 AA .1083 .975 .5619 671 13100 823
Petunia 750.0 37 AA .1424 .997 .5893 703 13100 847
Cattail 750 61 AA .1109 .998 .5892 703 13500 847
Arbutus 795 37 AA .1466 1.026 .6245 745 13900 878
Lilac 795.0 61 A .1142 1.027 .6248 745 14300 879
Cockscomb 900 37 AA .156 1.092 .7072 844 15400 948
Snapdragon 900 61 AA .1215 1.093 .7072 844 15900 948
Magnolia 954.0 37 AA .1606 1.124 .7495 894 16400 982
Goldenrod 954.0 61 A .1251 1.125 .7498 894 16900 983
Hawkweed 1000 37 AA .1644 1.151 .7854 937 17200 1010
Camellia 1000 61 AA .128 1.152 .7849 937 17700 1011
Bluebell 1033.5 37 AA .1671 1.17 .8114 969 17700 1031
Larkspur 1033.5 61 AA .1302 1.171 .8122 969 18300 1032
Marigold 1113.0 61 AA, A .1351 1.216 .8744 1043 19700 1079
Hawthorn 1192.5 61 AA, A .1398 1.258 .9363 1118 21100 1124
Narcissus 1272.0 61 AA, A .1444 1.3 .999 1192 22000 1169
Columbine 1351.5 61 AA, A .1488 1.34 1.0608 1267 23400 1212
Carnation 1431 61 AA, A .1532 1.378 1.1244 1341 24300 1253
Gladiolus 1510.5 61 A .1574 1.416 1.1869 1416 25600 1294
Coreopsis 1590.0 61 AA .1614 1.453 1.248 1490 27000 1333
Jessamine 1750.0 61 AA .1694 1.524 1.3748 1640 29700 1408
Cowslip 2000.0 91 A .1482 1.631 1.5697 1875 34200 1518
Sagebrush 2250 91 A .1572 1.73 1.7662 2130 37500 1612
Lupine 2500.0 91 A .1657 1.823 1.9623 2366 41900 1706
Bitterroot 2750 91 A .1738 1.912 2.1589 2603 46100 1793
Trillium 3000 127 A .1537 1.998 2.3564 2839 50300 1874
Bluebonnet 3500 127 A .166 2.158 2.7486 3345 58700 2024

No Sheath 225kv 2 Line Transmission Line Overhead Aluminum Conductors
For more information, don't hesitate to Contact with Vivian Yuan or email to me.
No Sheath 225kv 2 Line Transmission Line Overhead Aluminum Conductors

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier