Customization: | Available |
---|---|
Application: | Construction, Underground, Industrial, Power Station, Transmission and Distribution |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of US$ 0/Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Fire and flame-resistant cables play a vital role in building safety. Hongda is dedicated to developing low-smoke, zero toxicity cables as a means to assure the safety of people's lives.
Fire Resistant Cable
Size:1.5mm²~325mm²
Core:1C~50C
Conductor:Soft bare copper
Insulation :PE,XLPE
Jacket:PVC,LSZH
Rated Temperature:750ºC,840ºC,950ºC
Rated Voltage:600V
Fire Resistant Cable Application:Fire resistance cable may be built-in both structurally and by the correct choice and application of building materials.
In particular, the resistance-to-fire (of a cable) is the term used to describe how long a cable continues to operate in a fire. This may be of primary concern, for instance, in life safety of fire fighting installations.
Fire Resistant Cable
1 Core | Red or Black |
2 Cores | Red, Black |
3 Cores | Red, Yellow, Blue |
4 Cores | Red, Yellow, Blue, Black |
5 Cores | Red, Yellow, Blue, Black, Green |
Above 5 Cores | Black Cores with White numerals |
1 Core | Brown or Blue |
2 Cores | Brown, Blue |
3 Cores | Brown, Black, Grey |
4 Cores | Blue, Brown, Black, Grey |
5 Cores | Green/Yellow, Blue, Brown, Black, Grey |
Above 5 Cores | Black Cores with White numerals |
Other colours can be manufactured upon request.
Cable Design ParametersSize Cores x Sq. mm +Neutral (Sq. mm) |
Nominal Thickness of Insulation (mm) | Minimum Thickness of Inner Sheath(mm) | Armouring with flat strip (A2XFY/ 2XFY) | Armouring with round wire (A2XWY/ 2XWY) | ||||||||
Nominal Thickness of Arm.Strip (mm) |
Minimum Thickness of OuterSheath (mm) |
Approx.OverallDia. (mm) |
Approx. Net Wt.of Cable (kg/km) | Nominal Diameter of Wire(mm) | Minimum Thickness of Outer Sheath (mm) | Approx. Overall Dia. (mm) | Approx. Net Wt.of Cable (kg/km) | |||||
AL Cable A2XFY | CU Cable 2XFY | AL Cable A2XFY | CU Cable 2XWY | |||||||||
3×25+16 | 0.9/0.7 | 0.3 | 0.8 | 1.40 | 23 | 900 | 1400 | 1.6 | 1.40 | 25 | 1080 | 1685 |
3×35+16 | 0.9/0.7 | 0.3 | 0.8 | 1.40 | 25 | 1000 | 1800 | 1.6 | 1.40 | 27 | 1285 | 1980 |
3×50+25 | 1.0/0.9 | 0.3 | 0.8 | 1.40 | 28 | 1200 | 2300 | 1.6 | 1.56 | 30 | 1580 | 2685 |
3×70+35 | 1.1/0.9 | 0.4 | 0.8 | 1.56 | 32 | 1600 | 3200 | 2.0 | 1.56 | 35 | 2190 | 3690 |
3×95+50 | 1.1/1.0 | 0.4 | 0.8 | 1.56 | 35 | 2000 | 4100 | 2.0 | 1.56 | 38 | 2580 | 4585 |
3×120+70 | 1.2/1.1 | 0.4 | 0.8 | 1.72 | 39 | 2400 | 5100 | 2.0 | 1.72 | 42 | 3085 | 5680 |
3×150+70 | 1.4/1.1 | 0.5 | 0.8 | 1.72 | 43 | 2800 | 6000 | 2.0 | 1.88 | 46 | 3590 | 6790 |
3×185+95 | 1.6/1.1 | 0.5 | 0.8 | 1.88 | 47 | 3400 | 7400 | 2.5 | 2.04 | 51 | 4675 | 8615 |
3×240+120 | 1.7/1.2 | 0.6 | 0.8 | 2.04 | 53 | 4300 | 9500 | 2.5 | 2.20 | 56 | 5680 | 10485 |
3×300+150 | 1.8/1.4 | 0.6 | 0.8 | 2.20 | 57 | 5000 | 11500 | 2.5 | 2.36 | 60 | 6685 | 12990 |
3×400+185 | 2.0/1.6 | 0.7 | 0.8 | 2.52 | 66 | 6400 | 14500 | 3.2 | 2.68 | 71 | 8980 | 16980 |
3×500+240 | 2.2/1.7 | 0.7 | 0.8 | 2.68 | 74 | 7900 | 18000 | 3.2 | 2.84 | 79 | 10985 | 21485 |
3×630+300 | 2.4/1.8 | 0.7 | 0.8 | 3.00 | 82 | 9900 | 23000 | 4.0 | 3.00 | 88 | 14490 | 27985 |