• 3phase+Carring Line ABC Cable AAC 16 35 70 95mm2
  • 3phase+Carring Line ABC Cable AAC 16 35 70 95mm2
  • 3phase+Carring Line ABC Cable AAC 16 35 70 95mm2
  • 3phase+Carring Line ABC Cable AAC 16 35 70 95mm2
  • 3phase+Carring Line ABC Cable AAC 16 35 70 95mm2

3phase+Carring Line ABC Cable AAC 16 35 70 95mm2

Type: Insulated
Conductor Type: Stranded
Application: Overhead
Conductor Material: Aluminum
Sheath Material: Non
Insulation Material: XLPE/PE/PVC
Samples:
US$ 1/Meter 1 Meter(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
3+1core 16 35 70 95mm2
Material Shape
Round Wire
Certification
ISO9001, CE, CCC, RoHS
Insulation
XLPE/PE
Core
3/4/5
Standard
IEC/NFC33-209
Quality Guarantee
5 Years
Sheath Color
Black
Mark
Laser Type
Manufacture
Yes
Sample
Yes
Cable Parts
Yes
Transport Package
Wooden Drum
Specification
3+1 ABC cable
Trademark
Hongda
Origin
China, Henan
HS Code
8544492100
Production Capacity
3000km/Per Months

Product Description

Product Description

Aerial Bundled Conductor (ABC) Cables

Application
Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system.

It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.

Caledonian LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting.

This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable

Construction

Conductor Aluminium conductor, round stranded compressed (RM).
Insulation XPLE compound, UV-resistant.
Core Identification 1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm^2 and a minimum of 16 ribs for cores above 50 mm^2. In the case of five core bundles the surface of the protective core should be smooth.

 
 
Specific Parameters
 
 

Low Voltage Aerial Bundled Cable/ Low Voltage ABC Cable

The basic construction is as follows:
3 power cores consisting of standard aluminium conductors, insulated withXLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)

The messenger conductor can be of galvanised steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.

To be used at cotages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75oC for polyethylene insulated conductors or 90oC for crossliked polyethylene(XLPE) insulated conductors.
 

Application: the aerial bundled cables designed for fixed installation as overhead power lines up to 1000 V incl,To supply 120/220V aerial service for tem service at construction sites, as a service drop (power pole to service entrance) as a secondary cable (Pole to pole), or street lighting. For service at 1000V or lower at a maximum conductor temperature of 90ºC

Construction

Phase Conductor Aluminium conductor, round stranded compressed (RM).
Neutral Conductor Alloy aluminium conductor (AlMgSi), round stranded compressed (RM).
Insulation XLPE. Load-bearing / neutral core - marked with standard and producers phase core - marked with digits 1, 2, 3.
Assembly Cores and the neutral, conductor stranded together in right-hand lay, additionally 1, 2 or 3 cores of reduced cross section can be co-stranded.

Technical Data

Rated voltage kV 0.6/1
Test voltage Veff kV/Hz 4/50
Laying temperature °C min. -5
Operating temperature °C -30 ~ +90
Conductor temperature °C max. +90
Short-circuit temperature °C/s max. +250 /5
Bending radius (min.) mm 20 × O of cable

NFC 33-209 Standard ABC Cable Dimensions

 

ABC Cable NFC 33-209 Standard
Number of Cores x Nominal Cross Section Overal Diameter Weight Maximum Conductor Resistance Minimum Breaking Load Current Rating
No.x mm^2 mm Kg/Km Ω/Km KN A
2x10 RM 12.8 93 3.08 1.5 38
4x10 RM 15.4 183 3.08 1.5 38
2x16 RM 14.8 129 1.91 2.3 72
2x16 RN + 2x1.5 RE 14.8 176 1.910 / 12.100 2.3 72
4x16 RM 17.8 257 1.91 2.3 72
4x16 RN + 2x1.5 RE 17.8 304 1.910 / 12.100 2.3 72
2x25 RM 18 202 1.2 3.8 107
2x25 RM + 2x1.5 RE 18 249 1.200 / 12.100 3.8 107
4x25 RM 21.7 404 1.2 3.8 107
4x25 RM + 2x1.5 RE 21.7 451 1.200 / 12.100 3.8 107
2x35 RM 20.8 269 0.868 5.2 132
2x35 RM + 2x1.5 RE 20.8 316 0.868 / 12.100 5.2 132
4x35 RM 25.1 539 0.868 5.2 132
4x35 RM + 2x1.5 RE 25.1 586 0.868 / 12.100 5.2 132
2x50 RM 23.4 352 0.641 7.6 165
2x50 RM + 2x1.5 RE 23.4 399 0.641 / 12.100 7.6 165
1x54.6 RM + 3x25 RM 21.7 507 0.630 / 1.200 3.8 107
1x54.6 RM + 3x25 RM + 1x16 RM 24.3 573 0.630 / 1.200 / 1.910 3.8/2.3 107/72
1x54.6 RM + 3x25 RM + 2x16 RM 29.7 639 0.630 / 1.200 / 1.910 3.8/2.3 107/72
1x54.6 RM + 3x25 RM + 3x16 RM 31.1 705 0.630 / 1.200 / 1.910 3.8/2.3 107/72
1x54.6 RM + 3x35 RM 25.1 615 0.630 / 0.868 5.2 132
1x54.6 RM + 3x35 RM + 1x16 RM 28.1 680 0.630 / 0.868 / 1.910 5.2/2.3 132/72
1x54.6 RM + 3x35 RM + 2x16 RM 34.3 748 0.630 / 0.868 / 1.910 5.2/2.3 132/72
1x54.6 RM + 3x35 RM + 3x16 RM 35.9 814 0.630 / 0.868 / 1.910 5.2/2.3 132/72
1x54.6 RM + 3x35 RM + 1x25 RM 28.1 714 0.630 / 0.868 / 1.200 5.2/3.8 132/107
1x54.6 RM + 3x50 RM 28.2 741 0.630 / 0.641 7.6 165
1x54.6 RM + 3x50 RM + 1x16 RM 31.6 806 0.630 / 0.641 / 1.910 7.6/2.3 165/72
1x54.6 RM + 3x50 RM + 2x16 RM 38.6 875 0.630 / 0.641 / 1.910 7.6/2.3 165/72
1x54.6 RM + 3x50 RM + 3x16 RM 40.4 940 0.630 / 0.641 / 1.910 7.6/2.3 165/72
1x54.6 RM + 3x50 RM + 1x25 RM 31.6 841 0.630 / 0.641 / 1.200 7.6/3.8 165/107
1x54.6 RM + 3x70 RM 33 950 0.630 / 0.443 10.2 205
1x54.6 RM + 3x70 RM + 1x16 RM 37 1014 0.630 / 0.443 / 1.910 10.2/2.3 205/72
1x54.6 RM + 3x70 RM + 2x16 RM 45.2 1083 0.630 / 0.443 / 1.910 10.2/2.3 205/72
1x54.6 RM + 3x70 RM + 3x16 RM 47.3 1148 0.630 / 0.443 / 1.910 10.2/2.3 205/72
1x54.6 RM + 3x70 RM + 1x25 RM 37 1048 0.630 / 0.443 / 1.200 10.2/3.8 205/107
1x54.6 RM + 3x70 RM + 2x25 RM 45.2 1150 0.630 / 0.443 / 1.200 10.2/3.8 205/107
1x54.6 RM + 3x70 RM + 3x25 RM 47.3 1250 0.630 / 0.443 / 1.200 10.2/3.8 205/107
1x54.6 RM + 3x95 RM 37.4 1176 0.630 / 0.320 13.5 240
1x54.6 RM + 3x95 RM + 1x16 RM 41.9 1243 0.630 / 0.320 / 1.910 13.5/2.3 240/72

Please check the specification, Our competitive price will send you in 12 hours.  we can customize other cross-sections on request.

 

Packaging&Delivery

3phase+Carring Line ABC Cable AAC 16 35 70 95mm2
3phase+Carring Line ABC Cable AAC 16 35 70 95mm2

Packaging Details:Wooden drums,steel wooden drums or as your requirement
Delivery Time:Normally within 10 days (detailly depend on the order quantity)

 Contact us

Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software. 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now