XLPE or PE Insulated Aerial Bundled Cables
Product Description
Description
For aerial reticulation to residential and ruial areas where reliability, safety and low installation costs are required. Reduction of bushfire hazards and frequent tree lopping in uncleared areas.
Cable Design
Conductor: Hard Drawn Compacted Aluminium
Insulation: X-90 XLPE or PE
Insulation color: Black
Identification: Fully Ribbed Neutral, Ribbed phase cores
Product Parameters
Characteristics
Character |
Section Area |
Stranded number of wire |
Conductor diameter |
Average thickness of insulation |
Cable diameter |
Maximum Linear Resistance at 20ºC |
Phase line and lighting line |
16 |
7 |
4.6~5.1 |
1.2 |
7.0~7.8 |
1.91 |
25 |
7 |
5.8~6.3 |
1.4 |
8.6~9.4 |
1.20 |
35 |
7 |
6.8~7.3 |
1.6 |
10.0~10.9 |
0.868 |
50 |
7 |
7.9~8.4 |
1.6 |
11.1~12.0 |
0.641 |
70 |
12 |
9.7~10.3 |
1.8 |
13.3~14.2 |
0.443 |
95 |
19 |
11.0~12.0 |
1.8 |
14.6~15.7 |
0.320 |
120 |
19 |
12.0~13.1 |
1.8 |
15.6~16.7 |
0.253 |
150 |
19 |
13.9~15.0 |
1.7 |
17.3~18.6 |
0.206 |
Natural |
54.6 |
7 |
9.2~9.6 |
1.6 |
12.3~13.0 |
0.63 |
70 |
7 |
10.0~10.2 |
1.5 |
12.3~13.6 |
0.50 |
95 |
19 |
12.2~12.9 |
1.6 |
15.3~16.3 |
0.343 |
Guide |
1.5 |
1 |
1.5 |
1.2 |
3.7~4.2 |
12.1 |
Overhead Insulated Bt Twisted Cable Bundled wires without neutral carriers
2x16mm2 , 2x16+2x1.5mm2
2x25mm2 , 2x25+2x1.5mm2
2x35mm2, 2x35+2x1.5mm2
2x50mm2, 2x50+2x1.5mm2
4x16mm2, 4x16+2x1.5mm2
4x25mm2, 4x25+2x1.5mm2
4x35mm2, 4x35+2x1.5mm2
Overhead Insulated Bt Twisted Cable Bundled wires with neutral carriers
1x54.6mm2+3x25mm2+Kx16mm2
1x54.6mm2+3x35mm2+Kx16mm2
1x54.6mm2+3x50mm2+Kx16mm2
1x54.6mm2+3x70mm2+Kx16mm2
1x54.6mm2+3x30mm2+Kx25mm2
1x70mm2+3x70mm2+Kx16mm2
1x70mm2+3x95mm2+Kx16mm2
1x70mm2+3x120mm2+Kx16mm2
1x70mm2+3x150mm2+Kx16mm2
1x95mm2+3x120mm2+Kx16mm2
1x95mm2+3x150mm2+Kx16mm2
K is indicates the number of common lighting wires; this number can be 0, 1, 2, 3.
Packaging & Shipping
Note:
Compliant cables are secured to utility poles outside. In special cases, it can be laid on the wall or ceiling with tensile stress or without tensile stress; it must not be laid in open space, soaked in water, or used in buried power grids.
Overhead Insulated Bt Twisted Cable must be protected from damage during storage and transport
Overhead Insulated Bt Twisted Cable terminations must contain insulation covers to prevent water penetration and humidity during transport, storage and laying.
Overhead Insulated Bt Twisted Cable must be laid and used without impairing their performance. In this environment, the following points must be considered:
a) Operating conditions, such as concentration of installed cables, influence of outdoor heat, solar radiation, etc.
b) laying mode
c) Adverse external influences
d) Potential aggressiveness of fauna and flora.
After Sales Service
For more information and cable inquiry or questions of Overhead Insulated Bt Twisted Cable, feel free
contact Vivian Yuan.