• Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby
  • Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby
  • Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby
  • Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby
  • Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby
  • Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby

Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby

Application: Construction, Underground, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Current: AC Cable
Insulation Material: XLPE
Sheath Material: PVC
Material Shape: Round Wire
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
N2xby Cable
Wire Core Material
Red Copper Wire
Certification
ISO, CCC
Model
Yjv22
Brand
OEM
Product Name
Galvanized Steel Tape Armoured N2xby Cable
Armoured Material
Steel Tape
Transport Package
Wooden Drum
Specification
N2xby Cable
Trademark
OEM
Origin
China(Mainland)
HS Code
8544492100
Production Capacity
50 Kilometer/Month

Product Description

Product Description

N2XBY cable is suitable for AC 50Hz power and distribution lines with rated voltage of 0.6/1kV, which can be used in fixed industrial power applications, underground tunnels, etc. Using steel wire armour offers great mechanical protection, making it rigid with a large radius.

Specifications
IEC 60228 Conductors
IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV) up to 35kV(Um=40.5kV) - Part 1: Cables for rated voltages of 1 kV(Um=1.2kV) and 3 kV(Um=3.6kV)


Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby
Cable Construction 

Single Core Cable 

1. Conductor: Copper or aluminum, Class 1: solid conductor, or Class 2: stranded conductor
2. Insulation: Polietileno reticulado XLPE
3. Inner sheath: Polyvinyl chloride PVC
4. Armour: Non-magnetic steel-tape
5. Outer sheath: Polyvinyl chloride PVC

Multi Core Cable 

1. Conductor: Copper or aluminum, Class 1: solid conductor, or Class 2: stranded conductor
2. Insulation: crosslinked polyethylene XLPE
3. Filler: Non-hygroscopic material
4. Binder tape: Non-hygroscopic material
5. Inner sheath: Polyvinyl chloride PVC
6. Armour: Steel-tape
7. Outer sheath: Polyvinyl chloride PVC
0.6/1kV-1 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max.D.C resistance of conductor(20ºC) Current carrying capacity 
mm2 mm mm mm mm kg/km Ω/km In Air(A) In Ground(A)
1X10 0.7 0.2 1.8 11.8 244.0 1.83 75 47
1X16 0.7 0.2 1.8 12.9 318.0 1.15 97 62
1X25 0.9 0.2 1.8 14.6 430.0 0.727 125 78
1X35 0.9 0.2 1.8 15.2 533.0 0.524 155 94
1X50 1.0 0.2 1.8 16.7 668.0 0.387 190 110
1X70 1.1 0.2 1.8 18.5 893.0 0.268 245 135
1X95 1.1 0.2 1.8 20.1 1157.0 0.193 300 160
1X120 1.2 0.2 1.8 21.7 1410.0 0.153 350 185
1X150 1.4 0.2 1.8 23.7 1705.0 0.124 400 205
1X185 1.6 0.2 1.8 25.7 2082.0 0.0991 460 235
1X240 1.7 0.2 1.8 28.0 2652.0 0.0754 - -
1X300 1.8 0.2 1.9 31.0 3259.0 0.0601 - -
1X400 2.0 0.2 2.0 35.0 4135.0 0.047 - -
                 
0.6/1kV-2 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max. D.C resistance of conductor(20ºC) Current carrying capacity 
mm2 mm mm mm mm kg/km Ω/km In Air(A) In Ground(A)
2X2.5 0.7 0.2 1.8 13.4 230 7.41 - 45
2X4 0.7 0.2 1.8 14.3 277 4.61 - 59
2X6 0.7 0.2 1.8 15.3 336 3.08 - 74
2X10 0.7 0.2 1.8 17.8 452 1.83 64 100
2X16 0.7 0.2 1.8 20.0 609 1.15 83 135
2X25 0.9 0.2 1.8 23.3 845 0.727 110 165
2X35 0.9 0.2 1.8 24.6 1065 0.524 135 200
2X50 1.0 0.2 1.8 27.2 1297 0.387 165 240
2X70 1.1 0.2 1.9 31.4 1775 0.268 210 295
2X95 1.1 0.2 2.0 35.5 2340 0.193 260 355
2X120 1.2 0.5 2.2 40.2 3238 0.153 305 405
2X150 1.4 0.5 2.3 44.2 3971 0.124 345 455
2X185 1.6 0.5 2.5 48.9 4845 0.0991 396 515
                 
0.6/1kV-3 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max.D.C resistance of conductor(20ºC) Current carrying capacity 
mm2 mm mm mm mm kg/km Ω/km In Air(A) In Ground(A)
3X2.5 0.7 0.2 1.8 13.9 265 7.41 - 35
3X4 0.7 0.2 1.8 14.8 328 4.61 - 50
3X6 0.7 0.2 1.8 16.0 410 3.08 - 60
3X10 0.7 0.2 1.8 18.6 560 1.83 64 85
3X16 0.9 0.2 1.8 21.0 775 1.15 83 110
3X25 0.9 0.2 1.8 24.6 1098 0.727 110 140
3X35 0.9 0.2 1.8 26.0 1410 0.524 135 170
3X50 1.0 0.2 1.9 28.9 1780 0.387 165 200
3X70 1.1 0.2 2.0 33.9 2475 0.268 210 245
3X95 1.1 0.5 2.2 39.0 3260 0.193 260 300
3X120 1.2 0.5 2.3 42.7 4477 0.153 305 335
3X150 1.4 0.5 2.4 47.5 5440 0.124 345 380
3X185 1.6 0.5 2.6 52.1 6707 0.0991 395 430
3X240 1.7 0.5 2.8 58.3 8533 0.0754 465 500
3X300 1.8 0.5 2.9 63.6 10455 0.0601 535 565
                 
0.6/1kV-4 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max.D.C resistance of conductor(20ºC) Current carrying capacity 
mm2 mm mm mm mm kg/km Ω/km In Air(A) In Ground(A)
4X2.5 0.7 0.2 1.8 14.7 308 7.41 - 35
4X4 0.7 0.2 1.8 15.8 388 4.61 - 50
4X6 0.7 0.2 1.8 17.0 488 3.08 - 60
4X10 0.7 0.2 1.8 20.0 681 1.83 64 85
4X16 0.9 0.2 1.8 22.7 960 1.15 83 110
4X25 0.9 0.2 1.8 26.7 1375 0.727 110 140
4X35 0.9 0.2 1.8 28.3 1779 0.524 135 170
4X50 1.0 0.2 2.1 32.0 2296 0.387 165 200
4X70 1.1 0.5 2.1 38.5 3175 0.268 210 245
4X95 1.1 0.5 2.3 42.9 4665 0.193 260 300
4X120 1.2 0.5 2.4 47.4 5728 0.153 305 335
4X150 1.4 0.5 2.6 52.3 6999 0.124 345 380
4X185 1.6 0.5 2.7 57.5 8657 0.0991 395 430
4X240 1.7 0.5 3.0 64.3 11000 0.0754 465 500
4X300 1.8 0.5 3.1 70.3 13587 0.0601 535 565
                 
0.6/1kV-5 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max.D.C resistance of conductor(20ºC) Current carrying capacity 
mm2 mm mm mm mm kg/km Ω/km In Air(A) In Ground(A)
5X2.5 0.7 0.2 1.8 15.6 350 7.41 - 35
5X4 0.7 0.2 1.8 16.8 447 4.61 - 50
5X6 0.7 0.2 1.8 18.2 569 3.08 - 60
5X10 0.7 0.2 1.8 21.6 805 1.83 64 85
5X16 0.7 0.2 1.8 24.6 1150 1.15 83 110
5X25 0.9 0.2 1.8 29.0 1655 0.727 110 140
5X35 0.9 0.2 1.9 31.0 2166 0.524 135 170
5X50 1.0 0.2 2.1 35.7 2945 0.387 165 200
5X70 1.1 0.5 2.3 42.4 4453 0.268 210 245
5X95 1.1 0.5 2.4 47.2 5862 0.193 260 300
5X120 1.2 0.5 2.6 51.8 7176 0.153 305 335
5X150 1.4 0.5 2.7 57.6 8770 0.124 345 380
5X185 1.6 0.5 2.9 63.8 10827 0.0991 395 430
5X240 1.7 0.5 3.2 70.7 13770 0.0754 465 500
5X300 1.8 0.5 3.4 78.0 16960 0.0601 535 565
                 
0.6/1kV-3+1 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max.D.C resistance of conductor(20ºC) Current carrying capacity 
mm2 mm mm mm mm kg/km Ω/km In Air(A) In Ground(A)
3X4+1X2.5 0.7/0.7 0.2 1.8 15.5 368 4.61/7.41 - 50
3X6+1X4 0.7/0.7 0.2 1.8 16.8 465 3.08/4.61 - 60
3X10+1X6 0.7/0.7 0.2 1.8 19.3 633 1.83/3.08 64 85
3X16+1X10 0.7/0.7 0.2 1.8 22.1 890 1.15/1.83 83 110
3X25+1X16 0.9/0.7 0.2 1.8 25.1 1272 0.727/1.15 110 140
3X35+1X16 0.9/0.7 0.2 1.8 26.8 1583 0.524/1.15 135 170
3X50+1X25 1/0.9 0.2 1.9 30.2 2030 0.387/0.727 165 200
3X70+1X35 1.1/0.9 0.2 2.0 35.1 2810 0.268/0.524 210 245
3X95+1X50 1.1/1.0 0.5 2.2 40.4 4135 0.193/0.387 260 300
3X120+1X70 1.2/1.1 0.5 2.3 45 5135 0.153/0.268 305 335
3X150+1X70 1.4/1.1 0.5 2.5 49.1 6120 0.124/0.268 345 380
3X185+1X95 1.6/1.1 0.5 2.8 54.3 7616 0.0991/0.193 395 430
3X240+1X120 1.7/1.2 0.5 2.8 59.1 9679 0.0754/0.153 465 500
3X300+1X150 1.8/1.4 0.5 3.0 66 11889 0.0601/0.124 535 565
                 
0.6/1kV-4+1 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max.D.C resistance of conductor(20ºC) Current carrying capacity 
mm2 mm mm mm mm kg/km Ω/km In Air(A) In Ground(A)
4X4+1X2.5 0.7/0.7 0.2 1.8 16.3 434 4.61/7.41 - 50
4X6+1X4 0.7/0.7 0.2 1.8 17.7 549 3.08/4.61 - 60
4X10+1X6 0.7/0.7 0.2 1.8 20.3 759 1.83/3.08 64 85
4X16+1X10 0.7/0.7 0.2 1.8 24 1079 1.15/1.83 83 110
4X25+1X16 0.9/0.7 0.2 1.8 28.1 1557 0.727/1.15 110 140
4X35+1X16 0.9/0.7 0.2 1.9 29.6 1962 0.524/1.15 135 170
4X50+1X25 1/0.9 0.2 2.0 34 2601 0.387/0.727 165 200
4X70+1X35 1.1/0.9 0.5 2.2 40.3 3916 0.268/0.524 210 245
4X95+1X50 1.1/1.0 0.5 2.3 44.8 5260 0.193/0.387 260 300
4X120+1X70 1.2/1.1 0.5 2.6 50.2 6545 0.153/0.268 305 335
4X150+1X70 1.4/1.1 0.5 2.8 54.6 7780 0.124/0.268 345 380
4X185+1X95 1.6/1.1 0.5 2.9 60.5 9688 0.0991/0.193 395 430
4X240+1X120 1.7/1.2 0.5 3.0 67.1 12253 0.0754/0.153 465 500
4X300+1X150 1.8/1.4 0.5 3.2 73.7 15078 0.0601/0.124 535 565
                 
0.6/1kV-3+2 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
Max.D.C resistance of conductor(20ºC) Current carrying capacity 
mm2 mm mm mm mm kg/km Ω/km In Air(A) In Ground(A)
3X4+2X2.5 0.7/0.7 0.2 1.8 16.6 412 4.61/7.41 - 50
3X6+2X4 0.7/0.7 0.2 1.8 18 525 3.08/4.61 - 60
3X10+2X6 0.7/0.7 0.2 1.8 20.9 714 1.83/3.08 64 85
3X16+2X10 0.7/0.7 0.2 1.8 24 1016 1.15/1.83 83 110
3X25+2X16 0.9/0.7 0.2 1.8 28.1 1465 0.727/1.15 110 140
3X35+2X16 0.9/0.7 0.2 1.9 29.6 1769 0.524/1.15 135 170
3X50+2X25 1/0.9 0.2 2.0 34 2316 0.387/0.727 165 200
3X70+2X35 1.1/0.9 0.5 2.2 40.3 3230 0.268/0.524 210 245
3X95+2X50 1.1/1.0 0.5 2.3 44.8 4766 0.193/0.387 260 300
3X120+2X70 1.2/1.1 0.5 2.5 50.2 6080 0.153/0.268 305 335
3X150+2X70 1.4/1.1 0.5 2.6 54.6 7005 0.124/0.268 345 380
3X185+2X95 1.6/1.1 0.5 2.8 60.5 8767 0.0991/0.193 395 430
3X240+2X120 1.7/1.2 0.5 3.0 67.1 11105 0.0754/0.153 465 500
3X300+2X150 1.8/1.4 0.5 3.2 73.7 13645 0.0601/0.124 535 565


Packing shipping

Packing 

Steel wooden drum (fumigation)
Cable length in each drum: 1000m/2000m or as per actual cable length requirements.


 Drum size:
As per cable length and container size
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!


Shipping Port:

Tianjin, Qingdao, or other ports as per your requireents.


Sea freight:
FOB/C&F/CIF quotation are all available.

 

*For some countries such as Africa countries, middle east countries, our sea freight quotation is much cheaper than clients get from local shipping agency.

Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby
 Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby 
Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby
Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby
Any problem and inquiry pls contact with Tina


Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now