Customization: | Available |
---|---|
Application: | Construction, Underground, Industrial, Power Station, Telecommunication |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of US$ 100/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Physical Properties | ||||||||
Power cores | ||||||||
Conductor sizes | (mm²) | 2.5 | 10 | 16 | 25 | 35 | 50 | 70 |
Maximum wire diameter | (mm) | 0.26 | 0.41 | 0.41 | 0.41 | 0.41 | 0.41 | 0.51 |
Approx. conductor diameter | (mm) | 2.1 | 4.2 | 5.3 | 6.8 | 8.5 | 10.3 | 11.9 |
Maximum screen wire diameter | (mm) | 0.21 | 0.31 | 0.31 | 0.31 | 0.31 | 0.31 | 0.31 |
Braided screen filling factor | (%) | 80 | 80 | 80 | 80 | 80 | 80 | 80 |
Approx. summarized screen cross-section for power cores (weighing | (mm²) | 8 | 19 | 22 | 25 | 27 | 32 | 37 |
method) | ||||||||
Pilot cores | ||||||||
Number of pilot cores | 2 | 2 | 2 | 2 | 2 | 2 | ||
Conductor sizes | (mm²) | 4 | 4 | 6 | 6 | 10 | 10 | |
Maximum wire diameter | (mm) | 0.31 | 0.31 | 0.31 | 0.31 | 0.41 | 0.41 | |
Approx. conductor diameter | (mm) | 2.7 | 2.7 | 4.2 | 4.2 | 5.3 | 5.3 | |
Earth cores | ||||||||
Number of earth cores | 1 | 1 | 1 | l | l | 1 | 1 | |
Conductor sizes | (mm²) | I.5 | 6 | 10 | 16 | 16 | 25 | 35 |
Maximum wire diameter | (mm) | 0.26 | 0.41 | 0.41 | 0.41 | 41 | 0.41 | 41 |
Approx. conductor diameter | (mm) | 1.7 | 3.3 | 4.2 | 5.3 | 5.3 | 6.8 | 8.5 |
Lay Ratio (maximum) | (x PCD) | 12 | 8 | 8 | 8 | 8 | 8 | 8 |
Cable diameter | ||||||||
Minimum | (mm) | 16.5 | 34.5 | 36.4 | 37 | 43.6 | 50.1 | |
Maximum | (mm) | 18.3 | 37.5 | 37.7 | 40 | 46.9 | 54 | |
Cable mass (approx.) | (kg/m) | 0.52 | 1.5 | 2.2 | 2.74 | 3.1 | 4.01 | 5.41 |
Minimum bending radius | (mm) | 100 | 210 | 310 | 320 | 370 | 430 | |
Maximum recommended tension | (kN) | 0.12 | 0.5 | 0.79 | 1.24 | 1.73 | 2.48 | 3.47 |
Electrical Properties | ||||||||
Power cores | ||||||||
Maximum cond. DC resistance @ 20°C (0/km) | 8.54 | 2.11 | 1.34 | 0.859 | 0.61 | 0.424 | 0.299 | |
Maximum cond. DC resistance @ 90°C (0/km) | 11.39 | 2.69 | 1.79 | 1.15 | 0.814 | 0.566 | 0.399 | |
Reactance | (0/km) | 0.121 | 0.108 | 0.103 | 0.1 | 0.09 | 0.09 | 0.088 |
Impedance (Z) @ 90°C | (0/km) | 11.39 | 2.69 | 1.79 | 1.15 | 0.819 | 0.573 | 0.409 |
Sustained current rating @ 30°C ambient | ||||||||
Laid out straight | (A) | 35 | 100 | 111 | 141 | 181 | 221 | 270 |
1 layer on drum | (A) | 29 | 81 | 91 | 120 | 151 | 180 | 231 |
2 layer on drum | (A) | 23 | 61 | 71 | 91 | 121 | 141 | 181 |
3 layer on drum | (A) | 16 | 41 | 51 | 61 | 81 | 101 | 121 |
Short circuit rating : | ||||||||
Symmetrical fault current | (kA for 1 sec) | 0.3 | 1.1 | 1.8 | 2.8 | 4 | 5.7 | 7.9 |
Earth fault current (screens) | (kA for 1 sec) | 0.3 | 0.6 | 1 | 1.6 | 2.1 | 3.l | 3.5 |
Vivian Yuan