Application: Construction, Underground, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Current: AC Cable
Insulation Material: XLPE
Sheath Material: PVC
Material Shape: Round Wire
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Packaging & Shipping
  • Company Profile
Overview

Basic Info.

Model NO.
n2xh cable
Wire Core Material
Aluminum
Certification
ISO, CCC
Model
Na2xy
Brand
OEM
Transport Package
Wooden Drum
Specification
1.5mm2 to 400mm2
Trademark
OEM
Origin
China(Mainland)
HS Code
8544492100
Production Capacity
500 Kilometer/Month

Product Description

Application:

Halogen-free power cables( N2XH ) with enhanced resistance to fire are used mostly in areas where harm to human life or material must be prevented in case of fire such as industrial and public buildings, hotels, subway systems, hospitals etc. These cables are suitable for dry and wet environments as well as for outer application but are not suitable for direct burial into earth or water.

Cable structure:

  • Solid or stranded Cu core according to DIN VDE 0295 cl. 1 or 2, IEC 60228 cl. 1 or 2
  • Core insulation of halogen free, cross-linked polyethylene compound
  • Cores color coded according to DIN VDE 0293-308, green-yellow earth core in the outer layer, from 3 cores above
  • Cores stranded in layers with optimal lay lenght
  • For N2XCH version, concentric conductor of Cu tape or Cu wire
  • Halogen free sheath of thermoplastic polymer compound, color black

Technical data:

  • Power and control cable according to DIN VDE 0276 part 604
  • Temperature range during installation from -5°C to +50°C; fixed from -40°C to +90°C
  • Nominal voltage Uo/U 0,6/1 kV
  • Test voltage a.c. 4000 V
  • Minimum bending radius for single core approx. 15 x cable diameter, multicore approx. 12 x cable diameter

Tests:

  • Flame-retardant to DIN VDE 0482 part 266-2/HD 405.3/BS 4066 PT3/EN 50266-2/IEC 60332-3
  • Low corrosiveness of combustion gases to DIN VDE 0482 part 267/BS 6425 PT2/EN 50267-2-2/IEC 60754-2
  • Halogen-free to DIN VDE 0482 part 267/BS 6425 PT1/EN 50267-2-1/IEC 60754-1
  • Smoke density to DIN VDE 0482 part 268/HD 606/BS 7622 PT1,PT2/EN 50268-1,-2/IEC 61034-1,-2

 

Color codes N2XH :

  • 2-core cable: blue/brown
  • 3-core cable: brown/black/grey
  • 4-core cable: blue/brown/black/grey
  • from 7 conductors above, black cores with white numbering

NOTE:

  • CE = the product is conformed with the EC Low-Voltage Directive 73/23/EEC.
  • rm = round conductor stranded
  • re = round conductor plain
  • Conforms to RoHS.


Dimensions - Number of cores x cross-section
Design Construction of the individual keep the handlers safe The outer diameter thickness of insulation shell thickness Resistance to keep the handlers safe at 20 ° C Weight Cu weight of cable packaging
    rated about rated rated max.   about  
N x mm²   n x mm mm mm mm Ω/km kg/km kg/km  
1 x 1,5 RE 1 x 1,38 5,4 1,38 0,15 12,10 15,403 43 REZ
1 x 4 RE 1 x 2,25 6,4 2,25 0,20 4,61 5,869 75 REZ
1 x 16 RM 7 x 1,70 9,1 5,00 0,36 1,15 1,464 202 REZ
1 x 25 RM 7 x 2,13 11 6,10 0,48 0,727 0,925 302 REZ
1 x 70 RM 19 x 2,17 15 10,10 0,84 0,268 0,341 745 REZ
1 x 95 RM 19 x 2,52 17 11,90 0,97 0,193 0,246 986 REZ
1 x 185 RM 37 x 2,52 23 16,20 1,72 0,0991 0,126 1888 REZ
1 x 300 RM 61 x 2,50 28 20,60 2,34 0,0601 0,077 2945 REZ
 
2 x 1,5 RE 1 x 1,38 9 1,38 0,38 12,10 15,403 120 REZ
2 x 2,5 RE 1 x 1,78 10 1,78 0,45 7,41 9,433 154 REZ
2 x 16 RM 7 x 1,70 16 5,00 1,06 1,15 1,464 563 REZ
2 x 25 RM 7 x 2,13 20 6,10 1,52 0,727 0,925 840 REZ
2 x 35 RM 7 x 2,52 22 7,20 1,79 0,524 0,667 1106 REZ
2 x 120 RM 37 x 2,03 36 13,00 4,23 0,153 0,195 3343 REZ
2 x 300 RM 61 x 2,50 55 20,60 9,39 0,0601 0,077 8072 REZ
 
3 x 1,5 RE 1 x 1,38 9 1,38 0,44 12,10 15,403 135 REZ
3 x 2,5 RE 1 x 1,78 10 1,78 0,51 7,41 9,433 181 REZ
3 x 4 RE 1 x 2,25 11 2,25 0,60 4,61 5,869 242 REZ
3 x 10 RE 1 x 3,56 14 3,57 0,83 1,83 2,330 464 REZ
3 x 16 RM 7 x 1,70 17 5,00 1,22 1,15 1,464 697 REZ
N2XH
3 x 35 RM 7 x 2,52 23 7,20 2,08 0,524 0,667 1393 REZ
3 x 50 RM 19 x 1,83 26 8,30 2,56 0,387 0,493 1847 REZ
3 x 70 RM 19 x 2,17 31 10,10 3,43 0,268 0,341 2666 REZ
3 x 95 RM 19 x 2,52 36 11,90 4,17 0,193 0,246 3535 REZ
3 x 120 RM 37 x 2,03 38 13,00 4,74 0,153 0,195 4322 REZ
3 x 185 RM 37 x 2,52 48 16,20 7,40 0,0991 0,126 6742 REZ
3 x 300 RM 61 x 2,50 59 20,60 10,79 0,0601 0,077 10522 REZ
 
4 x 1,5 RE 1 x 1,38 10 1,38 0,52 12,10 15,403 163 REZ
4 x 2,5 RE 1 x 1,78 11 1,78 0,60 7,41 9,433 214 REZ
4 x 10 RE 1 x 3,56 16 3,57 1,03 1,83 2,330 586 REZ
4 x 16 RM 7 x 1,70 19 5,00 1,50 1,15 1,464 874 REZ
4 x 35 RM 7 x 2,52 26 7,20 2,57 0,524 0,667 1777 REZ
4 x 50 RM 19 x 1,83 29 8,30 3,15 0,387 0,493 2343 REZ
4 x 120 RM 37 x 2,03 43 13,00 5,98 0,153 0,195 5558 REZ
4 x 185 RM 37 x 2,52 53 16,20 9,35 0,0991 0,126 8657 REZ
4 x 240 RM 61 x 2,24 60 18,80 11,54 0,0754 0,096 11385 REZ
4 x 300 RM 61 x 2,50 65 20,60 13,44 0,0601 0,077 13539 REZ
N2XH
5 x 1,5 RE 1 x 1,38 11 1,38 0,62 12,10 15,403 193 REZ
5 x 4 RE 1 x 2,25 13 2,25 0,85 4,61 5,869 352 REZ
5 x 6 RE 1 x 2,76 15 2,76 0,99 3,08 3,921 475 REZ
5 x 16 RM 7 x 1,70 21 5,00 1,87 1,15 1,464 1081 REZ
5 x 25 RM 7 x 2,13 26 6,10 2,61 0,727 0,925 1631 REZ
5 x 50 RM 19 x 1,83 33 8,30 3,89 0,387 0,493 2915 REZ

N2xh 3X95+1X50 mm2 XLPE Frnc Low Smoke Halogen-Free Flame Fire Retardant Cable 0.6/1kv

Packaging & Shipping


N2xh 3X95+1X50 mm2 XLPE Frnc Low Smoke Halogen-Free Flame Fire Retardant Cable 0.6/1kv

Company Profile

Henan Hongda Cable Co., Ltd. located in No. 3, Changping Road, ZhanDian District, Jiaozuo, Wuzhi. Our factroy established in March of 2004. Our owns registered capital of RMB Fifty-one million six hundred and eighty thousand. Hongda Cable covers an area of 100,000 square meters, including 50,000 square meters of building area. We have more than 120 staff members and professional workers. our fixed assets of 90,000,000. We can provide more than 100 varieties, tens of thousands of specifications of wire and cable, with 10000 km annual production capacity

Henan Hongda Cable Co. Ltd. is the original Zhengzhou Hongda Cable Co. Ltd. established enterprise expansion. The company is committed to system R&D, design, manufacturing, marketing and service of cable products,We mainly aim at managing cross-linking XLPE insulated power cables, PVC insulated power cables, plastic insulated control cables, insulated overhead cables, and stranded aluminum and ACSR. At present, the cables' biggest cross area is 800 square meters with a maximum electric power of 35KV. The company has more than 300 (sets) domestic and oversea-leading production and testing equipment

N2xh 3X95+1X50 mm2 XLPE Frnc Low Smoke Halogen-Free Flame Fire Retardant Cable 0.6/1kv

 Our factory has advanced equipment of 20 sets production lines and 25 sets testing machinas, The production capacity is more than 12 million kilometers. We have skillful staff over 20-year experience,before starting working, every worker need to be trained professionally. Therefore, we can promise the product will be 100% quantified.

 

In our factory, every roll wire need to be test strictly, We wil test resistance, insulation thickness, the tension, stretch and so on. Before packing, every cable need to be test quantified, and we can make promise the 100% quantified.
N2xh 3X95+1X50 mm2 XLPE Frnc Low Smoke Halogen-Free Flame Fire Retardant Cable 0.6/1kv

 

Any problem and inquiry pls contact with Tina
Phone number: +86-15737156317

N2xh 3X95+1X50 mm2 XLPE Frnc Low Smoke Halogen-Free Flame Fire Retardant Cable 0.6/1kv

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now