2-2-4 Cockle Aluminum Triplex Overhead
Allowable Ampacity for 2-2-4 Cockle Aluminum Triplex Overhead XLP at 90°C: 150 Amps
Allowable Ampacity for 2-2-4 Cockle Aluminum Triplex Overhead Poly at 75°C: 120 Amps
Triplex aluminum wire has three conductors, with one of them being for neutral path, and two electrodes. The aluminum triplex cable is an electrical cable meant for power distributions from the utility lines to the consumer's premises through the weather head. It has an operational voltage rating at 600 V and the maximum temperature rating of 75°C. A bare messenger wire of this electrical cable is bonded closely on the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.
2-2-4 cockle triplex aluminum wire, 2-2-4 cockle triplex overhead wire, 2-2-4 cockle aluminum triplex, 2-2-4 cockle triplex conductor, 2-2-4 cockle overhead aluminum wire, 2-2-4 cockle aluminium overhead cables, 2-2-4 cockle overhead service drop conductors.
• ASTM B230: Aluminum wires, alloy 1350-H19 for electrical purposes.
• ASTM B231: Type 1350-H19 stranded aluminum conductors in concentric layers.
• ASTM B786: Aluminum alloy 1350-H19 stranded conductors with 19 wires, unilay formation to be subsequently insulated.
• ASTM B232: Aluminum Stranded Conductors Reinforced with Steel (ACSR).
• ASTM B398: Aluminum Alloy Wires, 6201-T81 for electrical purposes.
• ASTM B399: Type 6201-T81 aluminum alloy stranded conductors in concentric layers.
• ANSI/NEMA WC-70 ICEA S-76-474: Power cables supported by a messenger neutral, with weather resistant insulation for 0.6 kV.
• NTE INEN 2 572: Pre-assembled cables supported by a load-bearing neutral, with weather-resistant extruded insulation up to 0.6 kV.
In addition to all the requirements of the National Electrical Code.
Triplex aluminum wire has a concentric strand or compressed 1350-H19 series aluminum conductor.
Aluminum triplex cable has a bare ACSR messenger. Optional constructions include a messenger of AAC or 6201 alloy.
Triplex overhead aluminum wire has a black cross-linked polyethylene (XLP) insulation.
Specification Sheet
Code Word |
Phase Conductor | Bare Neutral Messenger | Weight Per 1000ft.(Ibs.) |
Allowable Ampacities+ |
||||||
Size (AWG) |
Stranding | Insul. Thick. (mils) |
Size (kcmil) |
Stranding | Rated Strength (Ibs.) |
XLP | POLY | XLP | POLY | |
ACSR NEUTRAL-MESSENGER | ||||||||||
Paludina | 6 | 1 | 45 | 6 | 43252 | 1190 | 109 | 109 | 85 | 70 |
Voluta | 6 | 7 | 45 | 6 | 43252 | 1190 | 114 | 114 | 85 | 70 |
Whelk | 4 | 1 | 45 | 4 | 43252 | 1860 | -- | 164 | 115 | 90 |
Periwinkle | 4 | 7 | 45 | 4 | 43252 | 1860 | 172 | 172 | 115 | 90 |
Conch | 2 | 7 | 45 | 2 | 43252 | 2850 | 262 | 262 | 150 | 120 |
Neritina | 1/0 | 7 | 60 | 1/0 | 43252 | 4380 | 420 | 420 | 205 | 160 |
Cenia | 1/0 | 9 | 60 | 1/0 | 43252 | 4380 | 414 | 414 | 205 | 160 |
Runcina | 2/0 | 7 | 60 | 2/0 | 43252 | 5310 | 520 | 520 | 235 | 185 |
Triton | 2/0 | 11 | 60 | 2/0 | 43252 | 5310 | 512 | 512 | 235 | 185 |
Mursia | 3/0 | 17 | 60 | 3/0 | 43252 | 6620 | 635 | 635 | 275 | 215 |
Zuzara | 4/0 | 18 | 60 | 4/0 | 43252 | 8350 | 789 | 789 | 315 | 245 |
Limpet | 336.4 | 19 | 80 | 336.4 | 43118 | 8680 | 1167 | 1167 | 420 | 325 |