• 2X16mm2 2X6AWG Duplex Service Drop Cables Aluminium/ XLPE Cable
  • 2X16mm2 2X6AWG Duplex Service Drop Cables Aluminium/ XLPE Cable
  • 2X16mm2 2X6AWG Duplex Service Drop Cables Aluminium/ XLPE Cable
  • 2X16mm2 2X6AWG Duplex Service Drop Cables Aluminium/ XLPE Cable
  • 2X16mm2 2X6AWG Duplex Service Drop Cables Aluminium/ XLPE Cable
  • 2X16mm2 2X6AWG Duplex Service Drop Cables Aluminium/ XLPE Cable

2X16mm2 2X6AWG Duplex Service Drop Cables Aluminium/ XLPE Cable

Type: Insulated
Conductor Type: Stranded
Application: Overhead
Conductor Material: Aluminum
Insulation Material: XLPE
Material Shape: Round Wire
Samples:
US$ 1/Meter 1 Meter(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
2x16mm duplex cable
Range of Application
Overhead
Certification
ISO9001, CE, CCC, RoHS
Brand
Hongda
Insulation
XLPE/PE/PVC
Core
2
Standard
IEC/NFC33-209
Quality Guarantee
10 Years
Sheath Color
Black
Mark
Laser Type
Manufacture
Yes
Sample
Yes
Cable Parts
Yes
Transport Package
Wooden Drum
Specification
2CORE ABC cable
Trademark
Hongda
Origin
China, Henan
HS Code
8544492100
Production Capacity
3000km/Per Months

Product Description

2x16mm2 2x6awg duplex Service Drop Cables Aluminium/ XLPE cable

Aerial Bundled Conductor (ABC) Cables

Application
Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system.

It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.

Caledonian LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting.

This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable

Construction

Conductor Aluminium conductor, round stranded compressed (RM).
Insulation XPLE compound, UV-resistant.
Core Identification 1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm^2 and a minimum of 16 ribs for cores above 50 mm^2. In the case of five core bundles the surface of the protective core should be smooth.

 
 
Specific Parameters
Type
Designation
Rated Voltage
No.of cores
Nominal cross section (mm²)
JKV
Copper conductor PVC insulated aerial cable
                 
 
 
 
 
0.6/1KV
 
 
 
 
1,2,4,3+k
16-240
JKLV
Aluminum conductor PVC insulated aerial cable
16-240
JKY
Copper conductor PE insulated aerial cable
16-240
JKLY
Aluminum conductor PE insulated aerial cable
16-240
JKYJ
Copper conductor XLPE insulated aerialcable
16-240
JKLYJ
Aluminum conductor XLPE insulated aerial cable
16-240
Nom.Cross sec(mm²)
Insulation Thickness(mm)
Outer Diameter Approx.(mm)
Conductor Resistance at 20 ºC(Ω/KM)
Test Voltage(KV/min)
Breaking Load(N)
Permissible ampacity at 25ºC(In Air)(A)
10
1
6
≤3.08
3.5/1
≥1650
65
16
1.2
7.4
≤1.91
3.5/1
≥2517
86
25
1.2
8.5
≤1.20
3.5/1
≥3762
111
35
1.4
9.8
≤0.868
3.5/1
≥5177
128
50
1.4
11.1
≤0.641
3.5/1
≥7011
154
70
1.4
12.8
≤0.443
3.5/1
≥10354
193
95
1.6
14.8
≤0.320
3.5/1
≥13727
236
120
1.6
16.2
≤0.253
3.5/1
≥17339
274
150
1.8
17.8
≤0.206
3.5/1
≥21033
316
185
2
20.2
≤0.164
3.5/1
≥26732
355
240
2.2
22.8
≤0.125
3.5/1
≥34679
419
300
2.2
25
≤0.100
3.5/1
≥43349
526
400
2.2
28
≤0.0778
3.5/1
≥55707
599

Low Voltage Aerial Bundled Cable/ Low Voltage ABC Cable

The basic construction is as follows:
3 power cores consisting of standard aluminium conductors, insulated withXLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)

The messenger conductor can be of galvanised steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.

To be used at cotages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75oC for polyethylene insulated conductors or 90oC for crossliked polyethylene(XLPE) insulated conductors.

Standards:
(1). BS 7870-5: Part 5: Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution
 

Packaging&Delivery

2X16mm2 2X6AWG Duplex Service Drop Cables Aluminium/ XLPE Cable
2X16mm2 2X6AWG Duplex Service Drop Cables Aluminium/ XLPE Cable

Packaging Details:Wooden drums,steel wooden drums or as your requirement
Delivery Time:Normally within 10 days (detailly depend on the order quantity)

 Contact us

Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software. 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now