• AC2xh Na2xh XLPE Insulated Halogen Free Power Cable
  • AC2xh Na2xh XLPE Insulated Halogen Free Power Cable
  • AC2xh Na2xh XLPE Insulated Halogen Free Power Cable
  • AC2xh Na2xh XLPE Insulated Halogen Free Power Cable
  • AC2xh Na2xh XLPE Insulated Halogen Free Power Cable
  • AC2xh Na2xh XLPE Insulated Halogen Free Power Cable

AC2xh Na2xh XLPE Insulated Halogen Free Power Cable

Application: Construction, Underground, Industrial, Power Station, Improved Fire Behaviour
Voltage: Low and Medium Voltage Cable
Current: AC Cable
Insulation Material: Halogen-Free, Cross-Linked Polyethylene
Sheath Material: Halogen-Free, Cross-Linkedpolymer Compound
Material Shape: Round Wire
Samples:
US$ 1/Meter 1 Meter(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
AC2XH, NA2XH
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, SGS
Model
N2xh
Brand
Hongda
Nominal Voltage Uo/U
600 / 1000 Volt
Test Voltage
4000 [V]AC
Temperature Range
-5°c Till +90°c
Operating Temperature
250c
Bending Radius
15-12 Diameter
Transport Package
Steel Wooden Drum
Specification
6mm2 to 300mm2
Trademark
Hongda
Origin
China
HS Code
8544492100
Production Capacity
500km/Month

Product Description

Product Description

 

AC2XH NA2XH XLPE Insulated halogen free power cable 

Application:
In earth, ducts, on support brackets, in dry and wet conditions etc., where one does not expect mechanical damages and the cables are not exposed to the mechanical tensile strain. In urban networks, industrial plants, electric power plants and other electricity consumers and for connection of control devices in industry, traffic etc.


NA2XH CABLE CONSTRUCTION:
Conductors: Al, class 1 (RE/SE) or class 2 (RM/SM) according to EN 60228
Insulation: XLPE compound DIX 3
Bedding: Extruded elastomere or plastomere compound or plastic tape
Sheath: HFFR compound HM 4
AC2xh Na2xh XLPE Insulated Halogen Free Power Cable

Technical data:
CPR class: Eca
Test voltage: 4 kV
Rated voltage: 0,6/1,0 kV
Bending radius (min): single-core - 15D;
multicore - 12D
Min. laying temperature: -5°C
Max. conductor temperature: 90°C
Max. short-circuit temperature: 250°C

Industry: Building & Construction, Transmission, Distribution & Power Networks
Standard: IEC 60502-1, SI 1516-1
Type: Industrial Cable, LSZH Cable, Power Network & Local Distribution Cable
 
Product Parameters

 

NA2XH CABLE DIMENSION:
SINGLE - CORE CABLES:
NOMINAL CROSS SECTION CONDUCTOR CONSTRUCTION NOM. THICKNESS OF INSUL. OUTER DIAM. (APPROX.) METAL WEIGHT CABLE WEIGHT (APPROX.) MAX. RESISTANCE AT 20°C CURRENT CAPACITY IN AIR CURRENT CAPACITY IN EARTH
mm2   mm mm kg/km kg/km ohm/km A A
1x16 rm 0,7 9,5 46,2 122 1,910 - -
1x25 rm 0,9 11,9 72,5 175 1,200 106 114
1x35 rm 0,9 13,0 101,5 206 0,868 130 136
1x50 rm 1,0 14,9 145,0 267 0,641 161 162
1x70 rm 1,1 17,0 203,0 358 0,443 204 199
1x95 rm 1,1 18,9 275,5 451 0,320 252 238
1x120 rm 1,2 20,7 348,0 546 0,253 295 272
1x150 rm 1,4 22,7 435,0 655 0,206 339 305
1x185 rm 1,6 25,1 536,5 800 0,164 395 347
1x240 rm 1,7 27,6 696,0 987 0,125 472 404
1x300 rm 1,8 31,9 870,0 1324 0,100 547 457
1x400 rm 2,0 34,9 1160,0 1640 0,0778 643 525
1x500 rm 2,2 39,3 1450,0 2030 0,0605 754 601
1x630 rm 2,4 44,1 1827,0 2400 0,0469 882 687
1x800 rm 2,6 46,5 2320,0 2505 0,0367 1019 776
1x1000 rm 2,8 52,0 2900,0 3115 0,0291 1157 865
AC2xh Na2xh XLPE Insulated Halogen Free Power Cable
THREE - CORE CABLES:
NOMINAL CROSS SECTION CONDUCTOR CONSTRUCTION NOM. THICKNESS OF INSUL. OUTER DIAM. (APPROX.) METAL WEIGHT CABLE WEIGHT (APPROX.) MAX. RESISTANCE AT 20°C CURRENT CAPACITY IN AIR CURRENT CAPACITY IN EARTH
mm2   mm mm kg/km kg/km ohm/km A A
3x16 rm 0,7 16,5 139,2 397 1,910 - -
3x25 rm 0,9 20,0 217,5 587 1,200 102 112
3x35 rm/sm 0,9 22,5 304,5 531 0,868 126 135
3x50 rm 1,0 27,6 435,0 1007 0,641 149 158
3x70 rm 1,1 30,6 609,0 1401 0,443 191 196
3x95 rm 1,1 33,8 826,5 1801 0,320 234 234
3x120 rm 1,2 37,5 1044,0 2226 0,253 273 268
3x50 se/sm 1,0 26,0 435,0 720 0,641 149 158
3x70 se/sm 1,1 29,7 609,0 963 0,443 191 196
3x95 se/sm 1,1 33,4 826,5 1246 0,320 234 234
3x120 se/sm 1,2 37,1 1044,0 1545 0,253 273 268
3x150 se/sm 1,4 41,2 1305,0 1916 0,206 311 300
3x185 se/sm 1,6 45,7 1609,5 2347 0,164 360 342
3x240 se/sm 1,7 51,6 2088,0 2987 0,125 427 398
3x300 se/sm 1,8 56,7 2160,0 3663 0,100 507 457
 
FOUR - CORE CABLES
NOMINAL CROSS SECTION CONDUCTOR CONSTRUCTION NOM. THICKNESS OF INSUL. OUTER DIAM. (APPROX.) METAL WEIGHT CABLE WEIGHT (APPROX.) MAX. RESISTANCE AT 20°C CURRENT CAPACITY IN AIR CURRENT CAPACITY IN EARTH
mm2   mm mm kg/km kg/km ohm/km A A
3x70+35 sm/sm 1,1/0,9 28,8 655,4 935 0,443/0,868 191 196
3x95+50 sm/sm 1,1/1,0 32,2 899,0 1120 0,320/0,641 234 234
3x120+70 sm/sm 1,2/1,1 34,6 1145,5 1430 0,253/0,443 273 268
3x150+70 sm/sm 1,4/1,1 38,5 1450,0 1950 0,206/0,443 311 300
3x185+95 sm/sm 1,6/1,1 42,4 1812,5 2345 0,164/0,320 360 342
3x240+120 sm/sm 1,7/1,2 47,2 2363,5 2980 0,125/0,253 427 398
4x35 sm 0,9 25,9 406,0 690 0,868 126 135
4x50 se/sm 1,0 28,4 580,0 832 0,641 149 158
4x70 se/sm 1,1 32,4 812,0 1234 0,443 191 196
4x95 se/sm 1,1 35,6 1102,0 1460 0,320 234 234
4x120 se/sm 1,2 40,6 1392,0 1861 0,253 273 268
4x150 se/sm 1,4 44,8 1740,0 2386 0,206 311 300
4x185 se/sm 1,6 49,2 2146,0 2866 0,164 360 342
4x240 se/sm 1,7 54,9 2784,0 3616 0,125 427 398
4x300 se/sm 1,8 58,8 3480,0 4500 0,100 507 457
AC2xh Na2xh XLPE Insulated Halogen Free Power Cable
FOUR - CORE CABLES WITH CONTROL CONDUCTOR
NOMINAL CROSS SECTION CONDUCTOR CONSTRUCTION NOM. THICKNESS OF INSUL. OUTER DIAM. (APPROX.) METAL WEIGHT CABLE WEIGHT (APPROX.) MAX. RESISTANCE AT 20°C CURRENT CAPACITY IN AIR CURRENT CAPACITY IN EARTH
mm2   mm mm kg/km kg/km ohm/km A A
4x16+1,5 re/rm 0,7 22,1 185,6 615 1,910 - -
4x25+1,5 re/rm 0,9 26,2 290,0 870 1,200 102 112
4x35+1,5 re/rm 0,9 28,9 406,0 1074 0,868 126 135
4x35+1,5 sm 0,9 23,1 406,0 630 0,868 126 135
4x50+1,5 se/sm 1,0 26,0 580,0 847 0,641 149 158
4x70+1,5 se/sm 1,1 30,0 812,0 1135 0,443 191 196
4x95+1,5 se/sm 1,1 33,6 1102,0 1480 0,320 234 234
4x120+1,5 se/sm 1,2 37,3 1392,0 1826 0,253 273 268
4x150+1,5 se/sm 1,4 42,0 1740,0 2282 0,206 311 300
4x185+1,5 se/sm 1,6 46,3 2146,0 2766 0,164 360 342
4x240+1,5 se/sm 1,7 52,1 2784,0 3572 0,125 427 398
4x300+1,5 se/sm 1,8 56,8 3480,0 4374 0,100 507 457
SIGNAL CU WIRE: Nominal cross section: 1,5 mm² Max. resistance at 20°C :12,1 Ω/km Nom. thicknss of insul. :0,7mm Outer diameter :2,9mm
 
FIVE - CORE CABLES
NOMINAL CROSS SECTION CONDUCTOR CONSTRUCTION NOM. THICKNESS OF INSUL. OUTER DIAM. (APPROX.) METAL WEIGHT CABLE WEIGHT (APPROX.) MAX. RESISTANCE AT 20°C CURRENT CAPACITY IN AIR CURRENT CAPACITY IN EARTH
mm2   mm mm kg/km kg/km ohm/km A A
5x16 rm 0,7 23,4 232,0 625 1,910 - -
5x25 rm 0,9 28,2 362,5 950 1,200 102 112
5x35 rm 0,9 31,0 507,5 1195 0,868 126 135
5x50 rm 1,0 36,8 725,0 1540 0,641 149 158
5x70 rm 1,1 42,8 1015,0 2240 0,443 191 196
5x95 rm 1,1 48,5 1377,5 3015 0,320 234 234
5x120 rm 1,2 53,6 1740,0 3580 0,253 273 268

NA2XH CABLE SELECTION:
In addition to our portfolio of European power cables we also supply British standard low voltage power cables including armoured cable with its LSZH outer sheathing. Our technical has a wealth of experience in providing support in the selection of the right cable for your application. Please call to discuss your specific application.

If you have another question, pls feel free to contact Vivian Yuan from Hongda Cable.
 
AC2xh Na2xh XLPE Insulated Halogen Free Power Cable

AC2xh Na2xh XLPE Insulated Halogen Free Power Cable

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now